| Water tank capacity | 40 L |
| Cooling capacity | 5.6 kW |
| Flow rate | 40 L/min |
| Circulating Water Pump | 0.37 kW |
| Refrigerant type | R22 (Or R134a / R407c) |
| Compressor motor | 1.5 kW |
| Voltage / Base | 1N / 220 V / 50 Hz |
| Dimension (L × W × H) | 850 × 520 × 800 mm |
| Net weight | 78 kg |
Air Cooled Chillers ADCC-502 is used for precise cooling in industries and facilities like medical labs and pharmaceutical industries. It is designed to remove heat from equipment and processes by transferring it to the surrounding air.
1. Does the Air Cooled Chiller ADCC-502 have a voltage protection feature?
Air Cooled Chiller ADCC-502 is equipped with advanced voltage protection features. It includes both high and low voltage protection to safeguard the system from power fluctuations. Additionally, it has earth leakage protection to prevent electrical faults and ensure user safety. These protections help to maintain stable and reliable operation, reducing the risk of damage to internal components.
2. What type of compressor motor does the Air Cooled Chiller ADCC-502 use?
Air Cooled Chiller ADCC-502 is equipped with a 1.5?kW compressor motor, delivering efficient and reliable performance. This motor is optimized to maintain steady cooling capacity while minimizing energy consumption. It has robust design that ensures durability for continuous operation. With precision engineering, the motor supports rapid startup and consistent output. Ideal for applications in medical, laboratory, and industrial environments requiring dependable thermal management.
3. Does the Air Cooled Chiller ADCC-502 have a frost protection feature?
Air Cooled Chiller ADCC-502 is designed with built-in frost protection to prevent coil freezing during low ambient conditions. This feature ensures uninterrupted operation and protects the internal components from potential damage. By automatically regulating the system when temperatures drop too low, it maintains optimal performance. Frost protection is especially beneficial in cold environments or temperature-sensitive applications.
4. What is the refrigerant control method used in the Air Cooled Chiller ADCC-502?
Air Cooled Chiller ADCC-502 utilizes a capillary tube control system for regulating refrigerant flow. This method ensures precise metering of refrigerant without the need for mechanical expansion valves. It offers simplicity, reliability, and low maintenance requirements. Capillary tubing provides stable cooling by reacting to pressure and temperature changes in the system.
5. What are the common applications of the Air Cooled Chiller ADCC-502?
Air Cooled Chiller ADCC-502 is commonly used in medical laboratories, pharmaceutical production, and industrial processes requiring precise cooling. It supports equipment such as analyzers, laser machines, and chemical reactors. The unit is also suitable for HVAC systems, food processing, and electronics cooling. It has compact design and reliable performance make it ideal for space-limited and temperature-sensitive environments.
6. What are Air Cooled Chillers?
Air Cooled Chillers are refrigeration systems that remove heat from a process or space using ambient air. They use fans to dissipate heat through air-cooled condenser coils. These chillers are commonly used in industrial, commercial, and HVAC applications. They are easy to install, require less maintenance, and don't need a separate cooling tower. Ideal for areas with limited water supply, they offer a cost-effective cooling solution.
7. What is the working principle of Air Cooled Chillers?
Air Cooled Chillers work by circulating refrigerant through a closed loop to absorb heat from the water or fluid being cooled. Their refrigerant vapor is compressed, raising its temperature and pressure. Fans then blow air over condenser coils to release this heat into the atmosphere, condensing the refrigerant back into a liquid. The cooled refrigerant returns to the evaporator to absorb more heat, continuing the cycle.
8. What are the benefits of Air-Cooled Chillers?
Air Cooled Chillers have lower maintenance needs compared to water-cooled systems, reducing operational costs. Their compact design makes them suitable for limited spaces and a variety of environments. They are energy-efficient, especially when equipped with variable speed compressors and fans. Additionally, Chillers are environmentally friendly by eliminating water consumption and minimizing heat discharge.
| Water tank capacity | 120 L |
| Cooling capacity | 22.4 kW |
| Flow rate | 150 L/min |
| Water tank capacity | 60 L |
| Cooling capacity | 14 kW |
| Flow rate | 100 L/min |
| Type | Air cooled |
| Refrigerant | R134a or R410A |
| Cooling Capacity | 1.2–2 kW |
| Water tank capacity | 140 L |
| Cooling capacity | 28 kW |
| Flow rate | 200 L/min |
| Temperature Range: | -45℃ to +30℃ |
| Temperature Control: | ±0.5℃ |
| Circulating Pump Max: | 20 L/min, 1.5bar |
| Temperature Range: | -25℃ to +35℃ |
| Temperature Control: | ±0.5℃ |
| Circulating Pump Max: | 20 L/min, 1.5bar |
| Temperature Range: | 5℃ to 35℃ |
| Refrigeration capacity: | 30 kW/h |
| Water flow: | 200 L/min |
| Temperature Range: | 5℃ to 35℃ |
| Refrigeration capacity: | 15 kW /h |
| Water flow: | 100 L/min |
| Temperature Range: | 5℃ to 35℃ |
| Refrigeration capacity: | 18 kW/h |
| Water flow: | 100 L/min |
| Temperature Range: | 5℃ to 35℃ |
| Refrigeration capacity: | 24 kW/h |
| Water flow: | 150 L/min |
| Temperature Range: | 5℃ to 35℃ |
| Working Current: | 9.4 to 10.8A |
| Refrigeration capacity: | 5.48 kW |
| Cooling: | 6 kW (5,160 kcal/h) |
| Compressor: | Rotary Compressor |
| Refrigerant: | R22 |
| Cooling: | 6 kW (5,160 kcal/h) |
| Compressor : | Rotary Compressor |
| Refrigerant: | R22 |
| Temperature: | 5℃ to 35℃ |
| Working Current: | 6.2 A |
| Refrigeration capacity: | 8.5 kW |
| Temperature Range: | 8℃ to 30℃ |
| Refrigeration capacity: | 2.7 kW |
| Flow meter : | 2.0 L/min |
| Type: | Integrated air cooling system |
| Cooling Capacity: | ≥ 1.2 kW |
| Pressure: | 0.08 to 0.17 MPa |
| Type: | Integrated water cooling system |
| Cooling Capacity: | ≥ 1.2 kW |
| Pressure: | 0.08 to 0.17 MPa |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 1.673 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 1.52 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 5.48 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 2.9 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 4 kW |
| Refrigerant: | R22 (Or R134a / R407c) |
| Temperature: | 5℃ to 30℃ |
| Cooling capacity: | 2.45 kW |
| Refrigerant: | R22 (Or R134a / R407c) |