Water Chiller ADWC-502

Water Chiller ADWC-502

Water Chiller ADWC-502 features a powerful 2 HP compressor that supports its high cooling capacity. It has corrosion-resistant piping and heat exchangers to ensure long-term reliability. This unit is equipped with an intuitive user interface that ensures straightforward and efficient operation. Designed with a closed-loop water cooling circuit it efficiently dissipates heat generated during high-energy pulses. Such Chiller is essential for maintaining controlled temperatures in various industrial, laboratory, and commercial applications.


Temperature Range 5℃ to 35℃
Working Current 9.4 to 10.8A
Refrigeration capacity 5.48 kW
Flow meter 2.0 L/min
Compressor power 2 HP
Power supply 220 V / 50 Hz
Water tank volume 24 L
Dimensions (L × B × H) 550 × 505 × 972 mm
Weight 80 kg
  • Seamless operation 
  • Stabilized temperature flow
  • User-friendly interface
  • Stainless steel design
  • Reliable water pump

Water Chiller ADWC-502 is used to maintain precise temperature control for sensitive experiments and equipment cooling. This system ensures stable and reliable cooling to protect samples and improve the accuracy of test results.

Water Chiller ADWC-502
Water Chiller ADWC-502

Frequently Asked Questions of Water Chiller ADWC-502

1. What key factors influence the performance and reliability of Water Chiller ADWC-502?

The performance of Water Chiller ADWC-502 is influenced by several key factors. Cooling capacity, temperature range, and flow rate determine the unit’s ability to manage heat. Ambient conditions and the type of coolant also impact efficiency. System load and proper pump selection ensure consistent operation. Regular maintenance and energy efficiency further enhance performance and reliability.

2. What type of cooling method does Water Chiller ADWC-502 use?

Water Chiller ADWC-502 uses a water-cooled cooling method, where water circulates through the system to absorb and remove heat. The heat absorbed by the water is then transferred to the refrigerant inside the chiller. This refrigerant is compressed and cooled by the condenser, effectively lowering the temperature. Such Chillers are efficient for continuous industrial use, providing stable temperature control.

3. What is common application of Laboratory Water Chiller ADWC-502?

Water Chiller ADWC-502 is commonly used to cool sensitive laboratory instruments and equipment. It helps maintain precise temperature control during experiments and testing. This ensures accurate and consistent results. Such chiller supports applications like chromatography, spectroscopy, and medical device cooling. Its reliable performance makes it essential for many research and clinical labs.

4. How does the Water Chiller ADWC-502 maintain temperature control?

This combination allows the chiller to provide reliable and precise temperature regulation for laboratory application.

5. What is the typical temperature range for Water Chiller ADWC-502?

Water Chiller ADWC-502 with a temperature range of 8°C to 30°C provide reliable cooling for a wide variety of applications. This range is ideal for maintaining stable temperatures in sensitive laboratory equipment and processes. It ensures samples and instruments operate within safe limits to prevent overheating or freezing. The chiller can be adjusted easily to meet specific cooling requirements. Overall, this temperature range supports consistent and precise thermal control in most lab environments.

6. How do a Water Chillers work?

Water Chiller works by circulating water through an evaporator where it absorbs heat from the system. They circulate coolant through closed-loop systems to absorb and remove heat. Refrigeration cycles cool the fluids, which then pass through heat exchangers or evaporators to lower temperatures effectively. Temperature sensors monitor conditions and adjust the cooling output for precise regulation. Together, these systems prevent overheating and maintain stable operational environments.

7. What maintenance is required for Water Chillers?

Maintenance of Water Chillers includes regularly cleaning or replacing filters to ensure proper airflow and water flow. Checking coolant levels and topping up as needed helps maintain efficient cooling. Inspecting pumps, compressors, and fans for wear or damage prevents breakdowns. Routine systems performance checks and leak inspections ensure reliable operation. Proper maintenance extends the lifespan and energy efficiency of the units.

8. What are the common applications of Water Chillers?

Water Chillers are commonly used to cool industrial machinery and manufacturing processes. They provide precise temperature control for laboratory equipment and medical devices. In HVAC systems, such units help regulate building temperatures efficiently. They are also used in food and beverage processing to maintain product quality. Overall, these systems support a wide range of applications requiring consistent and reliable cooling.

Similar Products of Water Chillers

Type Integrated air cooling system
Cooling Capacity ≥ 1.2 kW
Pressure 0.08 to 0.17 MPa
Temperature Range 5℃ to 35℃
Refrigeration capacity 18 kW/h
Power supply 3N / 380 V / 50 Hz
Cooling 6 kW (5,160 kcal/h)
Compressor Rotary Compressor
Refrigerant R22
Type Integrated water cooling system
Cooling Capacity ≥ 1.2 kW
Pressure 0.08 to 0.17 MPa

Low Temperature Circulating Chillers

Low Temperature Circulating Chiller ADLTC-501
Temperature Range:-25℃ to +35℃
Temperature Control:±0.5℃
Circulating Pump Max:20 L/min, 1.5bar
Low Temperature Circulating Chiller ADLTC-502
Temperature Range:-45℃ to +30℃
Temperature Control:±0.5℃
Circulating Pump Max:20 L/min, 1.5bar

Air Cooled Chillers

Air Cooled Chiller ADCC-505
Water tank capacity:70 L
Cooling capacity:16.8 kW
Flow rate:100 L/min
Air Cooled Chiller ADCC-507
Water tank capacity:140 L
Cooling capacity:28 kW
Flow rate:200 L/min
Air Cooled Chiller ADCC-501
Water tank capacity:40 L
Cooling capacity:2.8 kW
Flow Rate:40 L/min
Air Cooled Chiller ADCC-506
Water tank capacity:120 L
Cooling capacity:22.4 kW
Flow rate:150 L/min
Air Cooled Chiller ADCC-508
Type:Air cooled
Refrigerant:R134a or R410A
Cooling Capacity:1.2–2 kW
Air Cooled Chiller ADCC-504
Water tank capacity:60 L
Cooling capacity:14 kW
Flow rate:100 L/min
Air Cooled Chiller ADCC-503
Water tank capacity:60 L
Cooling capacity:8.4 kW
Flow rate:100 L/min
Air Cooled Chiller ADCC-502
Water tank capacity:40 L
Cooling capacity:5.6 kW
Flow rate:40 L/min

Laser Chillers

Laser Chiller ADLAC-506
Temperature:5℃ to 30℃
Cooling capacity:5.48 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-501
Temperature:5℃ to 30℃
Cooling capacity:1.52 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-505
Temperature:5℃ to 30℃
Cooling capacity:4 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-502
Temperature:5℃ to 30℃
Cooling capacity:1.673 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-504
Temperature:5℃ to 30℃
Cooling capacity:2.9 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-503
Temperature:5℃ to 30℃
Cooling capacity:2.45 kW
Refrigerant:R22 (Or R134a / R407c)