Laser Chiller ADLAC-504 frame integrates a 22-liter stainless steel water tank for efficient heat management. It supports a capillary tube refrigerant control method for precise temperature regulation. This unit is equipped with microcomputer control panel that provides reliable thermal control. Designed for high-efficiency operation, it features a condenser with brass fittings and corrugated aluminium fins to ensure superior heat dissipation. Our Chiller is used for cooling laser systems to prevent overheating and ensure consistent performance across various industries.


Temperature 5℃ to 30℃
Cooling capacity 2.9 kW
Refrigerant R22 (Or R134a / R407c)
Compressor power 0.885 × 1
Water Tank Volume 22 L
Water Flow 33 L/min
Dimension (L × B × H) 500 × 470 × 905 mm
Net Weight 63 kg
  • Efficient heat dissipation
  • Quiet pump operation
  • Reliable safety protections
  • Easy digital interface
  • Precise temperature control

Laser Chiller ADLAC-504 used in industrial and laboratory settings to keep laser systems cool and prevent overheating. It ensures precise temperature control, stable operation, and extends the lifespan of the equipment.

Frequently Asked Questions of Laser Chiller ADLAC-504

1. What is the cooling capacity of Laser Chiller ADLAC-504?

Laser Chiller ADLAC-504 has a cooling capacity of approximately 2.9 kW. This makes it suitable for a wide range of laser systems in both industrial and laboratory environments. It has powerful cooling ability ensures lasers operate within optimal temperature ranges. Maintaining stable temperatures helps prevent overheating and equipment damage. Overall, it supports efficient and reliable laser performance.

2. Which temperature range does Laser Chiller ADLAC-504 support?

Laser Chiller ADLAC-504 supports a temperature range from 5°C to 30°C, with an accuracy of ±0.3°C. This precise control ensures optimal cooling for various laser systems. The temperature range can be customized based on specific requirements. Maintaining this temperature range helps prevent overheating and ensures consistent laser performance.

3. What type of refrigerant control method does Laser Chiller ADLAC-504 use?

Laser Chiller ADLAC-504 utilizes a capillary tube as its refrigerant control method. This passive expansion system regulates the flow of refrigerant into the evaporator, enabling precise temperature control essential for laser systems. The capillary tube's simplicity and reliability make it well-suited for maintaining stable cooling performance in various industrial and laboratory applications.

4. What maintenance does Laser Chiller ADLAC-504 require?

Laser Chiller ADLAC-504 include replacing the cooling water every 3 to 6 months to prevent scale buildup and microbial growth. Filters should be cleaned or replaced every six months to maintain proper airflow and cooling performance. Their condenser needs regular cleaning to ensure effective heat dissipation. Use distilled or deionized water to prevent corrosion, and inspect monthly for leaks or unusual noises.

5. How simple is it to operate and monitor the Laser Chiller ADLAC-504?

The Laser Chiller ADLAC-504 is built for easy and intuitive use. It offers straightforward operation with a clear digital interface. Users can easily manage temperature settings and monitor system performance at a glance. Built-in diagnostics help quickly identify and address any issues. Its design focuses on simplicity, making it suitable for operators of all skill levels.

6. What are Laser Chillers?

Laser chillers are units that cool laser systems by removing excess heat during operation. They maintain stable temperatures to ensure lasers work efficiently and reliably. By circulating cooled liquid, they absorb and remove excess heat from laser components. Such Chillers are essential for extending the lifespan and accuracy of laser equipment.

7. What types of lasers are used by Laser Chillers?

Many types of lasers require Laser Chillers to manage heat during operation. Common examples include CO2 lasers, fiber lasers, and diode lasers. These lasers often operate at high power levels, producing significant heat that needs efficient cooling. Such Chillers are used across industries like manufacturing, medical treatments, and scientific research. The choice of systems depends on the specific laser type and its cooling demands.

8. How do Laser Chillers work?

Laser Chillers work by circulating a coolant through laser components to absorb heat generated during operation. The heated coolant then passes through a refrigeration system that cools it down. This cooled liquid is continuously cycled back to maintain a stable temperature. By efficiently removing heat, laser chillers prevent overheating and ensure consistent laser performance.

Similar Products of Laser Chillers

Temperature 5℃ to 30℃
Cooling capacity 5.48 kW
Refrigerant R22 (Or R134a / R407c)
Temperature 5℃ to 30℃
Cooling capacity 2.45 kW
Refrigerant R22 (Or R134a / R407c)
Temperature 5℃ to 30℃
Cooling capacity 1.673 kW
Refrigerant R22 (Or R134a / R407c)
Temperature 5℃ to 30℃
Cooling capacity 1.52 kW
Refrigerant R22 (Or R134a / R407c)

Low Temperature Circulating Chillers

Low Temperature Circulating Chiller ADLTC-502
Temperature Range:-45℃ to +30℃
Temperature Control:±0.5℃
Circulating Pump Max:20 L/min, 1.5bar
Low Temperature Circulating Chiller ADLTC-501
Temperature Range:-25℃ to +35℃
Temperature Control:±0.5℃
Circulating Pump Max:20 L/min, 1.5bar

Water Chillers

Water Chiller ADWC-504
Temperature Range:5℃ to 35℃
Refrigeration capacity:15 kW /h
Water flow:100 L/min
Water Chiller ADWC-508
Cooling:6 kW (5,160 kcal/h)
Compressor :Rotary Compressor
Refrigerant:R22
Water Chiller ADWC-501
Temperature Range:8℃ to 30℃
Refrigeration capacity:2.7 kW
Flow meter :2.0 L/min
Water Chiller ADWC-511
Type:Integrated water cooling system
Cooling Capacity:≥ 1.2 kW
Pressure:0.08 to 0.17 MPa
Water Chiller ADWC-503
Temperature:5℃ to 35℃
Working Current:6.2 A
Refrigeration capacity:8.5 kW
Water Chiller ADWC-506
Temperature Range:5℃ to 35℃
Refrigeration capacity:24 kW/h
Water flow:150 L/min
Water Chiller ADWC-507
Temperature Range:5℃ to 35℃
Refrigeration capacity:30 kW/h
Water flow:200 L/min
Water Chiller ADWC-505
Temperature Range:5℃ to 35℃
Refrigeration capacity:18 kW/h
Water flow:100 L/min
Water Chiller ADWC-509
Cooling:6 kW (5,160 kcal/h)
Compressor:Rotary Compressor
Refrigerant:R22
Water Chiller ADWC-510
Type:Integrated air cooling system
Cooling Capacity:≥ 1.2 kW
Pressure:0.08 to 0.17 MPa
Water Chiller ADWC-502
Temperature Range:5℃ to 35℃
Working Current:9.4 to 10.8A
Refrigeration capacity:5.48 kW

Air Cooled Chillers

Air Cooled Chiller ADCC-505
Water tank capacity:70 L
Cooling capacity:16.8 kW
Flow rate:100 L/min
Air Cooled Chiller ADCC-507
Water tank capacity:140 L
Cooling capacity:28 kW
Flow rate:200 L/min
Air Cooled Chiller ADCC-506
Water tank capacity:120 L
Cooling capacity:22.4 kW
Flow rate:150 L/min
Air Cooled Chiller ADCC-508
Type:Air cooled
Refrigerant:R134a or R410A
Cooling Capacity:1.2–2 kW
Air Cooled Chiller ADCC-502
Water tank capacity:40 L
Cooling capacity:5.6 kW
Flow rate:40 L/min
Air Cooled Chiller ADCC-504
Water tank capacity:60 L
Cooling capacity:14 kW
Flow rate:100 L/min
Air Cooled Chiller ADCC-503
Water tank capacity:60 L
Cooling capacity:8.4 kW
Flow rate:100 L/min
Air Cooled Chiller ADCC-501
Water tank capacity:40 L
Cooling capacity:2.8 kW
Flow Rate:40 L/min