Water Chiller ADWC-506
Water Chiller ADWC-506
Water Chiller ADWC-506 (Back view)

Water Chiller ADWC-506

Water Chiller ADWC-506 features a water tank with 120 litres capacity providing sufficient volume for efficient cooling. This unit operates within a broad temperature range, suitable for various environmental conditions. Designed with a cryogenic anomaly alarm, it alerts users to abnormal low-temperature faults for improved safety. It delivers reliable heat management performance, ensuring stable operation during continuous use. Our Chiller maintains reliable thermal regulation to protect sensitive instruments in lab and maintain consistent processes.


Temperature Range 5℃ to 35℃
Refrigeration capacity 24 kW/h
Power supply 3N / 380 V / 50 Hz
Water flow 150 L/min
Compressor power 6 kW
Water tank volume 125 L
Dimension (L × W × H) 1300 × 600 × 1360 mm
Weight 300 kg
  • Stainless steel construction
  • Energy-saving design
  • Multiple safety alert
  • Easy maintenance design
  • Microprocessor control unit

Water Chiller ADWC-506 are essential in laboratories for precise cooling of instruments and experiments. It helps to maintain controlled conditions to ensure accurate and reliable results.

Frequently Asked Questions of Water Chiller ADWC-506

1. What type of temperature control does the Water Chiller ADWC-506 use?

Water Chiller ADWC-506 features a microcomputer control system for accurate temperature management. It maintains stable cooling by continuously monitoring and adjusting the temperature. This precise control prevents fluctuations that could affect performance. This system ensures consistent conditions for sensitive equipment and processes. Overall, it enhances reliability and efficiency in cooling operations.

2. What is the function of the overload protection alert in the Water Chiller ADWC-506?

The overload protection in the Water Chiller ADWC-506 alert safeguards from electrical overloads. It automatically detects when the compressor or other components are under excessive strain. When triggered, the alert notifies users to prevent potential damage. This feature helps avoid costly repairs and downtime. Overall, it ensures safe and reliable operation of the Chiller.

3. What are the applications of Water Chiller ADWC -506?

Water Chiller ADWC-506 is suitable for a variety of applications in medical laboratories and industrial settings. It provides consistent and reliable cooling for delicate equipment and processes. The Chiller is ideal for maintaining stable temperatures in sensitive environments. It supports applications that require precise temperature control to ensure accuracy. Overall, it enhances performance and protects valuable instruments.

4. What safety measures are present in Water Chiller ADWC -506?

Water Chiller ADWC-506 includes safety measures such as overload protection to prevent motor damage and a high and low pressure switch to avoid refrigerant system failure. It has a water flow sensor to protect against pump dry run and a water level sensor to prevent flooding. Freeze protection prevents damage from excessively low temperatures. It also includes phase loss and phase reversal protection to safeguard electrical components. These features ensure reliable and safe operation under varying conditions.

5. Is the Water Chiller ADWC-506 capable of operating under various environmental conditions?

Water Chiller ADWC-506 is designed to operate effectively in a wide range of environmental conditions. It maintains stable cooling performance even when ambient temperatures fluctuate. The system has durable construction that helps to withstand different workplace environments. Advanced controls ensure consistent operation regardless of external factors. This makes it suitable for diverse laboratory and industrial settings.

6. How do a Water Chillers work?

Water Chiller works by circulating water through an evaporator where it absorbs heat from the system. They circulate coolant through closed-loop systems to absorb and remove heat. Refrigeration cycles cool the fluids, which then pass through heat exchangers or evaporators to lower temperatures effectively. Temperature sensors monitor conditions and adjust the cooling output for precise regulation. Together, these systems prevent overheating and maintain stable operational environments.

7. What maintenance is required for Water Chillers?

Maintenance of Water Chillers includes regularly cleaning or replacing filters to ensure proper airflow and water flow. Checking coolant levels and topping up as needed helps maintain efficient cooling. Inspecting pumps, compressors, and fans for wear or damage prevents breakdowns. Routine systems performance checks and leak inspections ensure reliable operation. Proper maintenance extends the lifespan and energy efficiency of the units.

8. What are the common applications of Water Chillers?

Water Chillers are commonly used to cool industrial machinery and manufacturing processes. They provide precise temperature control for laboratory equipment and medical devices. In HVAC systems, such units help regulate building temperatures efficiently. They are also used in food and beverage processing to maintain product quality. Overall, these systems support a wide range of applications requiring consistent and reliable cooling.

Similar Products of Water Chillers

Temperature Range 5℃ to 35℃
Working Current 9.4 to 10.8A
Refrigeration capacity 5.48 kW
Type Integrated air cooling system
Cooling Capacity ≥ 1.2 kW
Pressure 0.08 to 0.17 MPa
Temperature Range 5℃ to 35℃
Refrigeration capacity 18 kW/h
Power supply 3N / 380 V / 50 Hz
Temperature Range 8℃ to 30℃
Refrigeration capacity 2.7 kW
Flow meter 2.0 L/min

Low Temperature Circulating Chillers

Low Temperature Circulating Chiller ADLTC-502
Temperature Range:-45℃ to +30℃
Temperature Control:±0.5℃
Circulating Pump Max:20 L/min, 1.5bar
Low Temperature Circulating Chiller ADLTC-501
Temperature Range:-25℃ to +35℃
Temperature Control:±0.5℃
Circulating Pump Max:20 L/min, 1.5bar

Air Cooled Chillers

Air Cooled Chiller ADCC-506
Water tank capacity:120 L
Cooling capacity:22.4 kW
Flow rate:150 L/min
Air Cooled Chiller ADCC-504
Water tank capacity:60 L
Cooling capacity:14 kW
Flow rate:100 L/min
Air Cooled Chiller ADCC-502
Water tank capacity:40 L
Cooling capacity:5.6 kW
Flow rate:40 L/min
Air Cooled Chiller ADCC-508
Type:Air cooled
Refrigerant:R134a or R410A
Cooling Capacity:1.2–2 kW
Air Cooled Chiller ADCC-503
Water tank capacity:60 L
Cooling capacity:8.4 kW
Flow rate:100 L/min
Air Cooled Chiller ADCC-505
Water tank capacity:70 L
Cooling capacity:16.8 kW
Flow rate:100 L/min
Air Cooled Chiller ADCC-501
Water tank capacity:40 L
Cooling capacity:2.8 kW
Flow Rate:40 L/min
Air Cooled Chiller ADCC-507
Water tank capacity:140 L
Cooling capacity:28 kW
Flow rate:200 L/min

Laser Chillers

Laser Chiller ADLAC-505
Temperature:5℃ to 30℃
Cooling capacity:4 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-504
Temperature:5℃ to 30℃
Cooling capacity:2.9 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-503
Temperature:5℃ to 30℃
Cooling capacity:2.45 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-506
Temperature:5℃ to 30℃
Cooling capacity:5.48 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-502
Temperature:5℃ to 30℃
Cooling capacity:1.673 kW
Refrigerant:R22 (Or R134a / R407c)
Laser Chiller ADLAC-501
Temperature:5℃ to 30℃
Cooling capacity:1.52 kW
Refrigerant:R22 (Or R134a / R407c)