Laser Chiller ADLAC-506

Laser Chiller ADLAC-506

Laser Chiller ADLAC-506 offers a robust cooling capacity of 5.48 kW making it suitable for high-demand laser systems. It supports a capillary tube refrigerant control method, ensuring accurate heat regulation performance. Designed with a high-capacity airflow system to maximize heat removal and improve overall cooling efficiency. This system has an automatic shut-off feature that activates during pump overload conditions to safeguard the unit from damage. Such Chiller are used for cooling precision instruments and machinery that require stable and consistent temperature management.


Temperature 5℃ to 30℃
Cooling capacity 5.48 kW
Refrigerant R22 (Or R134a / R407c)
Compressor power 1.7 × 1
Water Tank Volume 24 L
Water Flow 33 L/min
Dimension (L × B × H) 550 × 505× 972 mm
Net Weight 80 kg
  • Digital microcomputer panel
  • Stainless steel build
  • Powerful performance
  • Stable output
  • Debris filtering mesh

Laser Chiller ADLAC-506 is used in industries such as manufacturing, research, and medical fields. It is designed to maintain optimal temperatures for laser equipment by preventing overheating, ensuring precise operation.

Frequently Asked Questions of Laser Chiller ADLAC-506

1. What is the temperature control accuracy and operating range of Laser Chiller ADLAC-506?

Laser Chiller ADLAC-506 provides accurate temperature control within a range of 5°C to 35°C. It maintains temperature stability with an error margin of ±1°C. This precision ensures sensitive equipment operates safely without overheating. The controlled environment helps extend the lifespan of connected devices. Overall, the chiller offers reliable and consistent thermal management for various applications.

2. How does the Laser Chiller ADLAC-506 work?

Laser Chiller ADLAC-506 works by circulating cooled fluid through laser equipment to absorb and remove heat. A refrigeration system lowers the fluid temperature to maintain a stable cooling environment. The circulation pump ensures continuous fluid flow for efficient heat exchange. Built-in sensors monitor temperature and adjust cooling output as needed. This process prevents overheating, ensuring optimal performance and protecting sensitive components.

3. What maintenance is required for Laser Chiller ADLAC-506?

Laser Chiller ADLAC-506 involves cleaning or replacing the dust filter to maintain airflow and checking coolant levels to ensure efficient operation. It’s important to inspect the pump and hoses for leaks or damage regularly. Periodic system checks, including temperature calibration and refrigerant levels, help keep the unit running smoothly. Proper upkeep extends the lifespan and reliability of the chiller.

4. What type of water inlet and outlet interfaces does Laser Chiller ADLAC-506?

Laser Chiller ADLAC-506 features a standard stainless steel water inlet and outlet interface. This connection is compatible with a variety of joints and hoses. It supports easy integration into an external closed-loop system. The durable stainless-steel construction ensures long-lasting, corrosion-resistant performance. This flexibility allows for versatile installation in different cooling setups.

5. What are the typical applications of Laser Chiller ADLAC-506?

Laser Chiller ADLAC-506 is commonly used to provide precise temperature control for laser systems. It helps maintain stable operating conditions by preventing equipment from overheating. This ensures high performance and accuracy in sensitive industrial and laboratory processes. The system has reliability supports continuous operation in demanding environments.

6. What are Laser Chillers?

Laser chillers are units that cool laser systems by removing excess heat during operation. They maintain stable temperatures to ensure lasers work efficiently and reliably. By circulating cooled liquid, they absorb and remove excess heat from laser components. Such Chillers are essential for extending the lifespan and accuracy of laser equipment.

7. What types of lasers are used by Laser Chillers?

Many types of lasers require Laser Chillers to manage heat during operation. Common examples include CO2 lasers, fiber lasers, and diode lasers. These lasers often operate at high power levels, producing significant heat that needs efficient cooling. Such Chillers are used across industries like manufacturing, medical treatments, and scientific research. The choice of systems depends on the specific laser type and its cooling demands.

8. How do Laser Chillers work?

Laser Chillers work by circulating a coolant through laser components to absorb heat generated during operation. The heated coolant then passes through a refrigeration system that cools it down. This cooled liquid is continuously cycled back to maintain a stable temperature. By efficiently removing heat, laser chillers prevent overheating and ensure consistent laser performance.

Similar Products of Laser Chillers

Temperature 5℃ to 30℃
Cooling capacity 1.52 kW
Refrigerant R22 (Or R134a / R407c)
Temperature 5℃ to 30℃
Cooling capacity 4 kW
Refrigerant R22 (Or R134a / R407c)
Temperature 5℃ to 30℃
Cooling capacity 2.9 kW
Refrigerant R22 (Or R134a / R407c)
Temperature 5℃ to 30℃
Cooling capacity 1.673 kW
Refrigerant R22 (Or R134a / R407c)

Low Temperature Circulating Chillers

Low Temperature Circulating Chiller ADLTC-502
Temperature Range:-45℃ to +30℃
Temperature Control:±0.5℃
Circulating Pump Max:20 L/min, 1.5bar
Low Temperature Circulating Chiller ADLTC-501
Temperature Range:-25℃ to +35℃
Temperature Control:±0.5℃
Circulating Pump Max:20 L/min, 1.5bar

Water Chillers

Water Chiller ADWC-505
Temperature Range:5℃ to 35℃
Refrigeration capacity:18 kW/h
Water flow:100 L/min
Water Chiller ADWC-502
Temperature Range:5℃ to 35℃
Working Current:9.4 to 10.8A
Refrigeration capacity:5.48 kW
Water Chiller ADWC-506
Temperature Range:5℃ to 35℃
Refrigeration capacity:24 kW/h
Water flow:150 L/min
Water Chiller ADWC-504
Temperature Range:5℃ to 35℃
Refrigeration capacity:15 kW /h
Water flow:100 L/min
Water Chiller ADWC-503
Temperature:5℃ to 35℃
Working Current:6.2 A
Refrigeration capacity:8.5 kW
Water Chiller ADWC-501
Temperature Range:8℃ to 30℃
Refrigeration capacity:2.7 kW
Flow meter :2.0 L/min
Water Chiller ADWC-507
Temperature Range:5℃ to 35℃
Refrigeration capacity:30 kW/h
Water flow:200 L/min
Water Chiller ADWC-509
Cooling:6 kW (5,160 kcal/h)
Compressor:Rotary Compressor
Refrigerant:R22
Water Chiller ADWC-510
Type:Integrated air cooling system
Cooling Capacity:≥ 1.2 kW
Pressure:0.08 to 0.17 MPa
Water Chiller ADWC-508
Cooling:6 kW (5,160 kcal/h)
Compressor :Rotary Compressor
Refrigerant:R22
Water Chiller ADWC-511
Type:Integrated water cooling system
Cooling Capacity:≥ 1.2 kW
Pressure:0.08 to 0.17 MPa

Air Cooled Chillers

Air Cooled Chiller ADCC-508
Type:Air cooled
Refrigerant:R134a or R410A
Cooling Capacity:1.2–2 kW
Air Cooled Chiller ADCC-504
Water tank capacity:60 L
Cooling capacity:14 kW
Flow rate:100 L/min
Air Cooled Chiller ADCC-502
Water tank capacity:40 L
Cooling capacity:5.6 kW
Flow rate:40 L/min
Air Cooled Chiller ADCC-505
Water tank capacity:70 L
Cooling capacity:16.8 kW
Flow rate:100 L/min
Air Cooled Chiller ADCC-503
Water tank capacity:60 L
Cooling capacity:8.4 kW
Flow rate:100 L/min
Air Cooled Chiller ADCC-507
Water tank capacity:140 L
Cooling capacity:28 kW
Flow rate:200 L/min
Air Cooled Chiller ADCC-506
Water tank capacity:120 L
Cooling capacity:22.4 kW
Flow rate:150 L/min
Air Cooled Chiller ADCC-501
Water tank capacity:40 L
Cooling capacity:2.8 kW
Flow Rate:40 L/min