| External Dimension (L×B×H) | 800×650×1000 mm |
| Internal Dimension (L×B×H) | 600×530×750 mm |
| Air Volume | 420 m³/h |
| Surface with Speed | Adjustable |
| Noise | 50db |
| Exhaust Air Diameter | 150 to 250 mm |
| Material | All steel/stainless steel |
| Fan Power | 48 W to 110 W |
| LED power | 6 W to 10 W |
| Main Body | 1.0mm Cold-rolled steel with epoxy powder coating |
| Inner Size | 5mm thick, acid and alkali resistant |
| Work Top | 12.7mm black physicochemical board; ceramic, marble, or stainless steel optional |
| Power Supply | 220 V |
| Power Consumption | 2000 W |
| Dimension (L×B×H) | 108×71×88 mm |
| Gross Weight | 110 Kg |
Our Ducted Benchtop Fume Hood ADDBF-502 is used in biotechnology, nanotechnology and environmental testing to safely remove hazardous fumes.
LED Light | 1 Pc |
Water Proof Socket | 2 Pc |
Soft Duct | 1 Pc |
Phenolic Resin Worktop | 1 Pc |
PP Worktop | 1 Pc |
Epoxy Resin Worktop | 1 Pc |
Ceramic Worktop | 1 Pc |
PVC Duct | 1 Pc |
1. What is the purpose of the Ducted Benchtop Fume Hood ADDBF-502?
The Ducted Benchtop Fume Hood ADDBF-502 is designed to safely extract and expel hazardous fumes, vapors, and particles generated during laboratory procedures. It protects users by maintaining negative pressure within the work zone and directing contaminants through an external duct system. This prevents exposure to harmful substances in the lab environment. It is ideal for chemical handling, solvent use, and testing that generates airborne contaminants. The unit promotes safety and clean air quality in various laboratory settings.
2. How is the Ducted Benchtop Fume Hood ADDBF-502 different from a ductless fume hood?
Unlike ductless hoods that rely on filters to recirculate air, the Ducted Benchtop Fume Hood ADDBF-502 channels exhaust directly outside via ductwork. This makes it more suitable for handling toxic or corrosive chemicals that can't be effectively filtered. It provides continuous removal of contaminants without filter saturation issues. It also eliminates the need for frequent filter replacements. Overall, it's ideal for high-risk or high-volume chemical applications.
3. What are the key features of the Ducted Benchtop Fume Hood ADDBF-502?
The Ducted Benchtop Fume Hood ADDBF-502 includes a chemical-resistant interior, adjustable airflow system, and clear viewing window for optimal visibility. It also features energy-efficient LED lighting and a built-in work surface. The hood supports external duct connections to ensure safe exhaust ventilation. Safety features like airflow monitors and alarm systems are included to maintain proper operation. Its compact benchtop design saves space while maximizing protection.
4. In which applications is the Ducted Benchtop Fume Hood ADDBF-502 commonly used?
This model is commonly used in pharmaceutical labs, chemical testing, academic research, and forensic science. It is ideal for experiments involving acids, solvents, and reactive substances. Industrial quality control and petrochemical labs also benefit from its containment capability. The unit ensures compliance with safety standards during volatile or toxic procedures. Its flexibility suits a wide range of scientific disciplines.
5. How do you maintain the Ducted Benchtop Fume Hood ADDBF-502 for long-term use?
Routine maintenance includes cleaning the internal surfaces with compatible non-corrosive solutions. Duct connections should be checked periodically for clogs or leaks. Airflow sensors and alarms must be tested regularly to ensure accurate performance. Scheduled servicing of the external ventilation system is essential. Following the manufacturer’s maintenance guidelines helps ensure optimal safety and equipment longevity.
| External Dimension (L×B×H) | 800×650×1050 mm |
| Internal Dimension (L×B×H) | 690×530×740 mm |
| Air Volume | 1200 m³/h |
| External Dimension (L×B×H) | 1200×600×1000 mm |
| Internal Dimension (L×B×H) | 1160×580×650 mm |
| Air Volume | 1850 m³/h |
| External Dimension (L×B×H) | 1500×800×1500 mm |
| Internal Dimension (L×B×H) | 1250×630×1150 mm |
| Air Volume | 1850 m³/h |
| External Dimension (L×B×H) | 1500×650×1000 mm |
| Internal Dimension (L×B×H) | 1300×530×750 mm |
| Air Volume | 1850 m³/h |
| Velocity: | 0.3 to 0.6 m/s |
| Power Supply: | AC220V/50Hz/0.8KW |
| Fluorescent Lamp: | 28 W × 1 |
| External Dimensions (W× D × H): | 950 × 730 × 1150 mm |
| Internal Dimensions (W× D × H): | 1200 × 1000 × 2250 mm |
| Surface Wind Speed: | 0.3 ~ 0.6 m/s |
| Velocity: | 0.3 to 0.6 m/s |
| Power Supply: | AC220V/50Hz/0.6KW |
| Fluorescent Lamp: | 28 W × 1 |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1425×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| Velocity: | 0.4 to 0.6 m/s |
| Filter Modular: | 4 |
| Air Pressure: | 960 Pa |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 920×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1125×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 725×620×700 mm |
| Internal Dimension (L×B×H): | 800×650×1900 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 890×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×800×2350 mm |
| Internal Dimension (L×B×H): | 950×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1300×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (W×D×H): | 1200 × 850 × 2350 mm |
| Internal Dimension (W×D×H): | 960 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H): | 1200 × 800 × 850 mm |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1390×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 800×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×800×2350 mm |
| Internal Dimension (L×B×H): | 1250×630×1150 mm |
| Maximum Opening: | 650mm |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1090×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (W×D×H): | 1800 × 850 × 2350 mm |
| Internal Dimension (W×D×H): | 1560 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H): | 1800 × 800 × 850 mm |
| External Dimension (L×B×H): | 800×650×1900 mm |
| Internal Dimension (L×B×H): | 690×530×740 mm |
| Air Volume: | 420 m³/h |
| External Dimension (L×B×H): | 1800×800×2350 mm |
| Internal Dimension (L×B×H): | 1550×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1000×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (W × D × H): | 1040 × 800 × 2200 mm |
| Internal Dimension (W × D × H): | 790× 670 × 1050mm |
| Maximum Opening: | 520 mm |
| External Dimension (L×B×H): | 800×650×1900 mm |
| Internal Dimension (L×B×H): | 600×530×750 mm |
| Air Volume: | 420 m³/h |
| External Dimension (W×D×H): | 1500 × 850 × 2350 mm |
| Internal Dimension (W×D×H): | 1260 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H): | 1500 × 800 × 850 mm |
| External Dimensions (W × D × H): | 1500 × 850 × 2350 mm |
| Internal Dimension (W × D × H): | 1300 × 590 × 900 mm |
| Air Volume: | 2300 m³/h |