| External Dimension (W×D×H) | 1500 × 850 × 2350 mm |
| Internal Dimension (W×D×H) | 1260 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H) | 1500 × 800 × 850 mm |
| Maximum Opening Height | 1050 mm |
| Exhaust Air Volume | 900 to 1700 m³/h |
| Air Velocity | 0.3 to 0.8 m/s |
| Exhaust Duct | 1 × 250 or 315 mmφ PP hood |
| Noise Level | ≤65 dB |
| Box 1 Packaging Dimension (W×D×H) | 1600 × 1030 × 1670 mm |
| Box 2 Packaging Dimension (W×D×H) | 1300 × 870 × 1060 mm |
| Gross Weight | 320 kg |
The Ducted Fume Hood ADDFH-513 is used in laboratories dealing with toxic fumes or volatile chemicals, providing reliable ventilation and containment to protect users and maintain a safe work environment.
30W LED Lamp | 1 Pc |
Bench-Mounted Single Water Tap | 1 Pc |
PP Oval Cup Sink | 1 Pc |
PP Exhaust Hood (250 or 315 mmφ) | 1 Pc |
Water-Proof Socket | 4 Pcs |
Acid cabinet and flammable cabinet | 1 pc |
PP Centrifugal Blower | 1 pc |
Flexible Pipe (4 meter) with pipe strap | 1 pc |
1. What accessories are included with the Ducted Fume Hood ADDFH-513, and what optional add-ons are available?
Standard accessories for the Ducted Fume Hood ADDFH-513 typically include a 30W LED lamp, bench-mounted water tap, polypropylene cup sink, waterproof sockets, and a PP exhaust hood compatible with 250 mm or 315 mm duct sizes. Optional accessories such as a PP centrifugal blower, flexible exhaust pipe with pipe strap, and additional gas taps can be added to enhance performance and adaptability based on the user’s specific application requirements.
2. What airflow features are integrated into the Ducted Fume Hood ADDFH-513 to ensure lab safety?
The Ducted Fume Hood ADDFH-513 is equipped with a by-pass airflow system that maintains constant airflow, even when the sash is in motion. It features an adjustable air velocity range that supports consistent negative pressure inside the hood, preventing contaminated air from escaping into the lab. These airflow control features are critical in ensuring that operators remain protected at all times during chemical handling or experimental work.
3. What safety features are included in the Ducted Fume Hood ADDFH-513?
The Ducted Fume Hood ADDFH-513 includes several integrated safety components such as a chemical-resistant work surface and a high-visibility LED lighting system. It also supports the installation of airflow monitoring alarms and emergency shutoff switches. These features collectively enhance operational safety, reduce the risk of chemical exposure, and ensure the unit complies with international laboratory safety standards.
4. What is the recommended maintenance procedure for the Ducted Fume Hood ADDFH-513 to ensure optimal performance?
To maintain peak performance and safety, the Ducted Fume Hood ADDFH-513 should be regularly cleaned using appropriate non-corrosive solutions. Operators should inspect the sash for smooth operation, verify airflow patterns using anemometers, and check the duct and blower for any blockages. Regular preventative maintenance and periodic airflow validation tests are essential to ensure that the system continues to operate within safety compliance standards.
5. What is the primary function of the Ducted Fume Hood ADDFH-513, and why is it important in laboratory settings?
The Ducted Fume Hood ADDFH-513 ensures safe handling of hazardous substances by removing toxic fumes and airborne contaminants through an external system. It is ideal for laboratories dealing with volatile chemicals, offering protection for users and maintaining a clean working environment. Its strong airflow, durable chemical-resistant build, and support for safety accessories make it ideal for research and academic labs needing reliable ventilation.
| External Dimension (L×B×H) | 1800×800×2350 mm |
| Internal Dimension (L×B×H) | 1550×630×1150 mm |
| Air Volume | 1850 m³/h |
| External Dimension (L×B×H) | 800×650×1900 mm |
| Internal Dimension (L×B×H) | 690×530×740 mm |
| Air Volume | 420 m³/h |
| External Dimension (L×B×H) | 1200×650×1900 mm |
| Internal Dimension (L×B×H) | 1090×530×740 mm |
| Air Volume | 1850 m³/h |
| Noise | 50db |
| Exhaust Air Diameter | 250 mm |
| Material | All steel/stainless steel |
| Velocity: | 0.3 to 0.6 m/s |
| Fluorescent Lamp: | 28 W × 1 |
| Dimensions (W× D × H): | 1800 × 850 × 2350 mm |
| Velocity: | 0.3 to 0.6 m/s |
| Fluorescent Lamp: | 28 W × 1 |
| Dimensions (W× D × H): | 1500 × 850 × 2350 mm |
| External Dimensions (W× D × H): | 950 × 730 × 1150 mm |
| Internal Dimensions (W× D × H): | 1200 × 1000 × 2250 mm |
| Surface Wind Speed: | 0.3 ~ 0.6 m/s |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 920×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1425×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1125×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 725×620×700 mm |
| Internal Dimension (L×B×H): | 800×650×1900 mm |
| Air treatment: | 220 to1200 m³/h |
| Velocity: | 0.4 to 0.6 m/s |
| Filter Modular: | 4 |
| Air Pressure: | 960 Pa |
| External Dimension (L×B×H): | 1200×800×1500 mm |
| Internal Dimension (L×B×H): | 950×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 800×600×1000 mm |
| Internal Dimension (L×B×H): | 760×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1000×650×1000 mm |
| Internal Dimension (L×B×H): | 800×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 800×650×1050 mm |
| Internal Dimension (L×B×H): | 690×530×740 mm |
| Air Volume: | 1200 m³/h |
| External Dimension (L×B×H): | 1200×650×1000 mm |
| Internal Dimension (L×B×H): | 1000×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×800×1500 mm |
| Internal Dimension (L×B×H): | 1250×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 800×650×1000 mm |
| Internal Dimension (L×B×H): | 600×530×750 mm |
| Air Volume: | 420 m³/h |
| External Dimension (L×B×H): | 1500×650×1050 mm |
| Internal Dimension (L×B×H): | 1390×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1800×800×1500 mm |
| Internal Dimension (L×B×H): | 1550×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×650×1050 mm |
| Internal Dimension (L×B×H): | 1090×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1000×650×1050 mm |
| Internal Dimension (L×B×H): | 890×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 650×600×1000 mm |
| Internal Dimension (L×B×H): | 610×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 650×600×1000 mm |
| Internal Dimension (L×B×H): | 610×580×650 mm |
| Air Volume: | 420 m³/h |
| External Dimension (L×B×H): | 1500×600×1000 mm |
| Internal Dimension (L×B×H): | 1460×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×650×1000 mm |
| Internal Dimension (L×B×H): | 1300×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×600×1000 mm |
| Internal Dimension (L×B×H): | 1160×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1000×600×1000 mm |
| Internal Dimension (L×B×H): | 960×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 650 × 650 × 1050 mm |
| Internal Dimension (L×B×H): | 540 × 530 × 740 mm |
| Air Volume: | 1200 m³/h |
| External Dimensions (W × D × H): | 1500 × 850 × 2350 mm |
| Internal Dimension (W × D × H): | 1300 × 590 × 900 mm |
| Air Volume: | 2300 m³/h |