| External Dimension (L×B×H) | 1500×800×2350 mm |
| Internal Dimension (L×B×H) | 1250×630×1150 mm |
| Maximum Opening | 650mm |
| Grounding Resistance | Up to 0.1 Ω |
| Air Volume | 600 to 1200 m³/h |
| Wind Speed | 0.3 to 0.8 m/s, adjustable |
| Pressure | No breakdown per minute at 1500 V |
| Work Surface Height | 1150 mm |
| Noise | Up to 62 dB (A) |
| Vibration Value | Up to 5 µm (RMS) |
| Main Body | 1.0mm Cold-rolled steel with epoxy powder coating |
| Inner Body Material | 5mm thick compact, acid and alkali resistant |
| Work Station | 12.7mm thick black physicochemical board |
| Power Supply | 220/110 V |
| Gross Weight | 128 kg |
Our Ducted Fume Hood ADDFH-506 is used in biotechnology, forensic labs and academics to safely extract hazardous fumes during various chemical processes.
Fan 1 Pc Water Faucet 1 Pc Water Sink 1 Pc LED Light 1 Pc Base Stand 1 Pc
Gas Tap 1 pc UV Lamp 1 pc Waterproof Socket 2 pc Active Carbon Filter 1 pc Foot Switch 1 pc PVC Duct (4 m) 1 pc
1. What is the main purpose of the Ducted Fume Hood ADDFH-506?
The Ducted Fume Hood ADDFH-506 is designed to safely ventilate hazardous fumes, vapors, and particulates generated during laboratory processes. It protects users by drawing contaminated air away from the work area through an external duct system. This ensures a cleaner and safer laboratory environment. The hood is ideal for chemical handling, mixing, and testing. It supports compliance with safety and environmental standards.
2. What materials are used in the construction of Ducted Fume Hood ADDFH-506?
The Ducted Fume Hood ADDFH-506 is built with high-quality cold-rolled steel coated with epoxy resin for chemical resistance. The inner chamber is typically lined with acid- and alkali-resistant material. The work surface may be offered in options like ceramic, stainless steel, or solid physicochemical boards. Its transparent sash is made from toughened glass or polycarbonate. This construction ensures long-term durability and safety in corrosive environments.
3. How is airflow managed in the Ducted Fume Hood ADDFH-506?
Ducted Fume Hood ADDFH-505 utilizes a ducted ventilation system that pulls air from the workspace through a blower connected to external ducts. Adjustable baffles and airflow regulators help control the speed and direction of air movement. It provides constant airflow to maintain negative pressure within the hood. This minimizes the risk of exposure to harmful fumes. An optional airflow monitor may be available for added safety assurance.
4. What are the standard safety features of Ducted Fume Hood ADDFH-505 ?
The Ducted Fume Hood ADDFH-506 typically includes a front sash with adjustable height to limit exposure and enhance containment. It also offers LED lighting for clear visibility without heat generation. Some models come with a digital control panel for fan speed and alarm systems for airflow disruption. The unit may have built-in sockets, gas taps, and water faucets for lab utility integration. These features support safe and convenient daily operations.
5. Where is the Ducted Fume Hood ADDFH-506 commonly used?
Ducted Fume Hood ADDFH-505 is widely used in laboratories dealing with chemicals, such as pharmaceutical labs, industrial R&D centers, and environmental testing facilities. It is also suitable for academic institutions, biotechnology labs, and petrochemical industries. Its versatility and robust construction make it ideal for various applications. It helps maintain a contaminant-free environment during sensitive experiments. Overall, it ensures operator protection and process integrity.
| External Dimension (L×B×H) | 1800×800×2350 mm |
| Internal Dimension (L×B×H) | 1550×630×1150 mm |
| Air Volume | 1850 m³/h |
| External Dimension (L×B×H) | 800×650×1900 mm |
| Internal Dimension (L×B×H) | 690×530×740 mm |
| Air Volume | 420 m³/h |
| External Dimension (L×B×H) | 1200×650×1900 mm |
| Internal Dimension (L×B×H) | 1090×530×740 mm |
| Air Volume | 1850 m³/h |
| External Dimension (W × D × H) | 1040 × 800 × 2200 mm |
| Internal Dimension (W × D × H) | 790× 670 × 1050mm |
| Maximum Opening | 520 mm |
| External Dimensions (W× D × H): | 950 × 730 × 1150 mm |
| Internal Dimensions (W× D × H): | 1200 × 1000 × 2250 mm |
| Surface Wind Speed: | 0.3 ~ 0.6 m/s |
| Velocity: | 0.3 to 0.6 m/s |
| Power Supply: | AC220V/50Hz/0.8KW |
| Fluorescent Lamp: | 28 W × 1 |
| Velocity: | 0.3 to 0.6 m/s |
| Power Supply: | AC220V/50Hz/0.6KW |
| Fluorescent Lamp: | 28 W × 1 |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1125×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 920×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1425×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| Velocity: | 0.4 to 0.6 m/s |
| Filter Modular: | 4 |
| Air Pressure: | 960 Pa |
| External Dimension (L×B×H): | 725×620×700 mm |
| Internal Dimension (L×B×H): | 800×650×1900 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 650×600×1000 mm |
| Internal Dimension (L×B×H): | 610×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1000×650×1050 mm |
| Internal Dimension (L×B×H): | 890×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1000×600×1000 mm |
| Internal Dimension (L×B×H): | 960×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×800×1500 mm |
| Internal Dimension (L×B×H): | 950×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×600×1000 mm |
| Internal Dimension (L×B×H): | 1460×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×800×1500 mm |
| Internal Dimension (L×B×H): | 1250×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 800×650×1050 mm |
| Internal Dimension (L×B×H): | 690×530×740 mm |
| Air Volume: | 1200 m³/h |
| External Dimension (L×B×H): | 1500×650×1000 mm |
| Internal Dimension (L×B×H): | 1300×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×650×1050 mm |
| Internal Dimension (L×B×H): | 1090×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1800×800×1500 mm |
| Internal Dimension (L×B×H): | 1550×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 800×600×1000 mm |
| Internal Dimension (L×B×H): | 760×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 800×650×1000 mm |
| Internal Dimension (L×B×H): | 600×530×750 mm |
| Air Volume: | 420 m³/h |
| External Dimension (L×B×H): | 1200×650×1000 mm |
| Internal Dimension (L×B×H): | 1000×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 650 × 650 × 1050 mm |
| Internal Dimension (L×B×H): | 540 × 530 × 740 mm |
| Air Volume: | 1200 m³/h |
| External Dimension (L×B×H): | 650×600×1000 mm |
| Internal Dimension (L×B×H): | 610×580×650 mm |
| Air Volume: | 420 m³/h |
| External Dimension (L×B×H): | 1500×650×1050 mm |
| Internal Dimension (L×B×H): | 1390×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×600×1000 mm |
| Internal Dimension (L×B×H): | 1160×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1000×650×1000 mm |
| Internal Dimension (L×B×H): | 800×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimensions (W × D × H): | 1500 × 850 × 2350 mm |
| Internal Dimension (W × D × H): | 1300 × 590 × 900 mm |
| Air Volume: | 2300 m³/h |