| External Dimension (L×B×H) | 1200×600×1000 mm |
| Internal Dimension (L×B×H) | 1160×580×650 mm |
| Air Volume | 1850 m³/h |
| Surface Wind Speed | 0.5 m/s |
| Noise | 50 db |
| Exhaust Air Diameter | 250 mm |
| Material | All steel /stainless steel |
| Fan Power | 110 W |
| LED Power | 20 W |
| Customizable | Customizable self-cleaning fume hood |
| Main Body | 1.0mm Cold-rolled steel with epoxy powder coating |
| Inner Size | 1.0mm Cold-rolled steel with epoxy powder coating |
| Work Top | 12.7mm black physicochemical board; ceramic, marble, or stainless steel optional |
| Power Consumption | 2000 W |
| Power Supply | 220 V |
Our Ducted Benchtop Fume Hood ADDBF-517 is widely used in chemical research, pharmaceutical development, and academic laboratories to safely ventilate hazardous fumes, vapors, and particles during sensitive experimental procedures.
10 A Socket | 1 Pc |
Fan | 1 Pc |
Duct | 1 Pc |
LED | 1 Pc |
Speed governor | 1 Pc |
Water Faucet | 1 Pc |
Water Sink | 1 Pc |
LCD Panel | × 1 Pc |
Electric Damper | × 1 Pc |
Manual Damper | × 1 Pc |
Gas cock | × 1 Pc |
Drip Rack | × 1 Pc |
1. What is the primary function of the Ducted Benchtop Fume Hood ADDBF-517?
The primary function of the Ducted Benchtop Fume Hood ADDBF-517 is to safely remove hazardous fumes, vapors, and airborne contaminants generated during laboratory procedures. It uses a ducted ventilation system that channels the air out of the lab, ensuring a clean and safe working environment. This protects both personnel and samples from exposure to harmful substances. The hood also provides physical protection through its front sash barrier. It is ideal for use in labs handling volatile chemicals.
2. How is the Ducted Benchtop Fume Hood ADDBF-517 different from a ductless fume hood?
Unlike ductless models, the Ducted Benchtop Fume Hood ADDBF-517 requires an external ducting system to expel air outside the building. This makes it suitable for handling high volumes of toxic or flammable chemicals that cannot be recirculated. Ductless hoods filter and recirculate air, but ducted ones like this offer superior safety for more aggressive applications. It ensures consistent airflow and better contaminant control. Therefore, it is often preferred in research, chemical, and industrial labs.
3. What materials is the Ducted Benchtop Fume Hood ADDBF-517 constructed from?
The Ducted Benchtop Fume Hood ADDBF-517 is typically constructed from high-quality chemical-resistant materials such as epoxy-coated steel or stainless steel. These materials ensure long-term durability and resistance to corrosion from harsh chemicals. The worktop is often made from phenolic resin or ceramic for added chemical and thermal resistance. It is designed to withstand demanding lab environments. The materials used also make cleaning and maintenance easy.
4. Does the Ducted Benchtop Fume Hood ADDBF-517 have airflow monitoring?
Yes, Ducted Benchtop Fume Hood ADDBF-517 come equipped with an airflow monitoring system. This system helps ensure that the hood is maintaining proper face velocity to effectively contain hazardous fumes. Audible or visual alarms alert users when airflow falls below safe levels. Monitoring systems improve lab safety and compliance with safety standards. Regular calibration and maintenance are recommended for accurate readings.
5. Where can the Ducted Benchtop Fume Hood ADDBF-517 be used?
The Ducted Benchtop Fume Hood ADDBF-517 is ideal for use in chemical laboratories, pharmaceutical labs, academic research institutions, and industrial testing facilities. It is particularly useful where work involves acids, solvents, or toxic gases. Due to its ducted design, it suits environments with higher hazard levels. It also supports applications that generate continuous fume loads. Its compact benchtop form makes it suitable for smaller lab spaces without compromising safety.
| External Dimension (L×B×H) | 1500×800×1500 mm |
| Internal Dimension (L×B×H) | 1250×630×1150 mm |
| Air Volume | 1850 m³/h |
| External Dimension (L×B×H) | 1000×600×1000 mm |
| Internal Dimension (L×B×H) | 960×580×650 mm |
| Air Volume | 1850 m³/h |
| External Dimension (L×B×H) | 1500×600×1000 mm |
| Internal Dimension (L×B×H) | 1460×580×650 mm |
| Air Volume | 1850 m³/h |
| External Dimension (L×B×H) | 1500×650×1050 mm |
| Internal Dimension (L×B×H) | 1390×530×740 mm |
| Air Volume | 1850 m³/h |
| Velocity: | 0.3 to 0.6 m/s |
| Power Supply: | AC220V/50Hz/0.6KW |
| Fluorescent Lamp: | 28 W × 1 |
| External Dimensions (W× D × H): | 950 × 730 × 1150 mm |
| Internal Dimensions (W× D × H): | 1200 × 1000 × 2250 mm |
| Surface Wind Speed: | 0.3 ~ 0.6 m/s |
| Velocity: | 0.3 to 0.6 m/s |
| Power Supply: | AC220V/50Hz/0.8KW |
| Fluorescent Lamp: | 28 W × 1 |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1125×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1425×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 920×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 725×620×700 mm |
| Internal Dimension (L×B×H): | 800×650×1900 mm |
| Air treatment: | 220 to1200 m³/h |
| Velocity: | 0.4 to 0.6 m/s |
| Filter Modular: | 4 |
| Air Pressure: | 960 Pa |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1300×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (W×D×H): | 1200 × 850 × 2350 mm |
| Internal Dimension (W×D×H): | 960 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H): | 1200 × 800 × 850 mm |
| External Dimension (L×B×H): | 1800×800×2350 mm |
| Internal Dimension (L×B×H): | 1550×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (W×D×H): | 1500 × 850 × 2350 mm |
| Internal Dimension (W×D×H): | 1260 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H): | 1500 × 800 × 850 mm |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1090×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1000×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×800×2350 mm |
| Internal Dimension (L×B×H): | 1250×630×1150 mm |
| Maximum Opening: | 650mm |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 800×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×800×2350 mm |
| Internal Dimension (L×B×H): | 950×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (W × D × H): | 1040 × 800 × 2200 mm |
| Internal Dimension (W × D × H): | 790× 670 × 1050mm |
| Maximum Opening: | 520 mm |
| External Dimension (W×D×H): | 1800 × 850 × 2350 mm |
| Internal Dimension (W×D×H): | 1560 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H): | 1800 × 800 × 850 mm |
| External Dimension (L×B×H): | 800×650×1900 mm |
| Internal Dimension (L×B×H): | 600×530×750 mm |
| Air Volume: | 420 m³/h |
| External Dimension (L×B×H): | 800×650×1900 mm |
| Internal Dimension (L×B×H): | 690×530×740 mm |
| Air Volume: | 420 m³/h |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 890×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1390×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimensions (W × D × H): | 1500 × 850 × 2350 mm |
| Internal Dimension (W × D × H): | 1300 × 590 × 900 mm |
| Air Volume: | 2300 m³/h |