| External Dimension (L×B×H) | 1500×650×1000 mm |
| Internal Dimension (L×B×H) | 1300×530×750 mm |
| Air Volume | 1850 m³/h |
| Surface Wind Speed | Adjustable |
| Noise | 50db |
| Exhaust Air Diameter | 150 to 250 mm |
| Material | All steel/stainless steel |
| Fan Power | 48 W to 110 W |
| LED power | 6 W to 10 W |
| Main Body | 1.0mm Cold-rolled steel with epoxy powder coating |
| Inner Size | 5mm thick, acid and alkali resistant |
| Work Top | 12.7mm black physicochemical board; ceramic, marble, or stainless steel optional |
| Power Consumption | 2000 W |
| Dimensions (L×B×H) | 150×54×90 mm |
| Gross Weight | 130 Kg |
Our Ducted Benchtop Fume Hood ADDBF-505 is used in pharmaceutical labs, chemical research and forensic science to safely capture and exhaust hazardous fumes.
10 A Socket | 1 Pc |
Fan | 1 Pc |
Duct | 1 Pc |
LED light | 1 Pc |
LCD Panel | × 1 Pc |
Electric Damper | × 1 Pc |
Manual Damper | × 1 Pc |
Drip Rack | × 1 Pc |
1. What is the primary function of the Ducted Benchtop Fume Hood ADDBF-505 ?
The primary function of the Ducted Benchtop Fume Hood ADDBF-505 is to provide a ventilated enclosure that safely removes hazardous chemical fumes, vapors, and airborne particles during laboratory procedures. It helps protect laboratory personnel by maintaining negative pressure and preventing exposure to toxic substances. This model is ducted, meaning it connects to an external exhaust system for effective air removal. It is ideal for laboratories handling volatile chemicals or conducting sensitive experiments.
2. What types of filters or ducting are required for Ducted Benchtop Fume Hood ADDBF-505?
Since the Ducted Benchtop Fume Hood ADDBF-505 is a ducted unit, it does not rely on internal filters but instead connects to external ductwork that vents air outside the building. The ducting must be chemical-resistant and properly sealed to ensure safety and performance. Depending on the application, additional pre-filters or scrubbers may be installed in the exhaust line. It is important to follow local building and safety codes for duct installation.
3. Is the Ducted Benchtop Fume Hood ADDBF-505 suitable for handling corrosive chemicals?
Yes, the Ducted Benchtop Fume Hood ADDBF-505 is designed to handle corrosive chemicals, featuring an interior constructed from durable, chemical-resistant materials. The work surface, sash, and inner linings are all built to withstand harsh reagents and acids. However, it's important to verify the chemical compatibility of the specific substances in use. For extremely aggressive chemicals, additional liners or coatings may be recommended.
4. How is airflow monitored or controlled in the Ducted Benchtop Fume Hood ADDBF-505?
The Ducted Benchtop Fume Hood ADDBF-505 typically includes an airflow monitor or alarm system to ensure consistent and safe ventilation. Some models feature digital displays to show real-time airflow levels or face velocity. Operators can be alerted if airflow drops below safe limits, helping prevent exposure. Airflow is controlled through a fan system connected to external ductwork, which should be appropriately sized for the unit.
5. What maintenance does the Ducted Benchtop Fume Hood ADDBF-505 require?
Routine maintenance includes cleaning the interior surfaces, inspecting the duct connections, and checking for any signs of corrosion or wear. While there are no internal filters to replace, the external exhaust system should be inspected regularly. The sash mechanism and lighting should also be tested to ensure smooth operation. If equipped, airflow monitors and alarms must be calibrated periodically. Keeping a maintenance log is recommended for safety compliance and performance tracking.
| External Dimension (L×B×H) | 1200×800×1500 mm |
| Internal Dimension (L×B×H) | 950×630×1150 mm |
| Air Volume | 1850 m³/h |
| External Dimension (L×B×H) | 650×600×1000 mm |
| Internal Dimension (L×B×H) | 610×580×650 mm |
| Air Volume | 1850 m³/h |
| External Dimension (L×B×H) | 800×650×1000 mm |
| Internal Dimension (L×B×H) | 600×530×750 mm |
| Air Volume | 420 m³/h |
| External Dimension (L×B×H) | 1200×650×1050 mm |
| Internal Dimension (L×B×H) | 1090×530×740 mm |
| Air Volume | 1850 m³/h |
| Velocity: | 0.3 to 0.6 m/s |
| Fluorescent Lamp: | 28 W × 1 |
| Dimensions (W× D × H): | 1500 × 850 × 2350 mm |
| Velocity: | 0.3 to 0.6 m/s |
| Fluorescent Lamp: | 28 W × 1 |
| Dimensions (W× D × H): | 1800 × 850 × 2350 mm |
| External Dimensions (W× D × H): | 950 × 730 × 1150 mm |
| Internal Dimensions (W× D × H): | 1200 × 1000 × 2250 mm |
| Surface Wind Speed: | 0.3 ~ 0.6 m/s |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1425×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| Velocity: | 0.4 to 0.6 m/s |
| Filter Modular: | 4 |
| Air Pressure: | 960 Pa |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1125×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 920×620×700 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 725×620×700 mm |
| Internal Dimension (L×B×H): | 800×650×1900 mm |
| Air treatment: | 220 to1200 m³/h |
| External Dimension (L×B×H): | 800×650×1900 mm |
| Internal Dimension (L×B×H): | 600×530×750 mm |
| Air Volume: | 420 m³/h |
| External Dimension (L×B×H): | 1500×800×2350 mm |
| Internal Dimension (L×B×H): | 1250×630×1150 mm |
| Maximum Opening: | 650mm |
| External Dimension (L×B×H): | 1800×800×2350 mm |
| Internal Dimension (L×B×H): | 1550×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1090×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 800×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×800×2350 mm |
| Internal Dimension (L×B×H): | 950×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (W×D×H): | 1500 × 850 × 2350 mm |
| Internal Dimension (W×D×H): | 1260 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H): | 1500 × 800 × 850 mm |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1300×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (W × D × H): | 1040 × 800 × 2200 mm |
| Internal Dimension (W × D × H): | 790× 670 × 1050mm |
| Maximum Opening: | 520 mm |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1000×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (W×D×H): | 1200 × 850 × 2350 mm |
| Internal Dimension (W×D×H): | 960 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H): | 1200 × 800 × 850 mm |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 890×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (W×D×H): | 1800 × 850 × 2350 mm |
| Internal Dimension (W×D×H): | 1560 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H): | 1800 × 800 × 850 mm |
| External Dimension (L×B×H): | 800×650×1900 mm |
| Internal Dimension (L×B×H): | 690×530×740 mm |
| Air Volume: | 420 m³/h |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1390×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimensions (W × D × H): | 1500 × 850 × 2350 mm |
| Internal Dimension (W × D × H): | 1300 × 590 × 900 mm |
| Air Volume: | 2300 m³/h |