| External Dimension (L×B×H) | 1500×650×1900 mm |
| Internal Dimension (L×B×H) | 1425×620×700 mm |
| Air treatment | 220 to1200 m³/h |
| Noise | 8db |
| Fan Power | 48 W to 110 W |
| LED power | 6 W to 10 W |
| Main Body | 1.0 mm thick cold-rolled steel with epoxy powder coating |
| Work Top | 12.7 mm solid physiochemical board; ceramic or stainless-steel optional worktop |
| Power supply | 220 V |
| Power consumption | 2000 W |
| Dimensions (L×B×H) | 160×88×120 mm |
| Gross Weight | 240 Kg |
Our Ductless Fume Hood ADDLF-505 is used in pharmaceutical, food testing, and environmental labs to safely filter hazardous fumes without external ventilation.
10 A Socket | 1 Pc |
Fan | 1 Pc |
LED Light | 1 Pc |
Duct | 1 Pc |
LCD touch screen | 1 Pc |
UV lamp | 1 Pc |
Universal caster | 1 Pc |
Ductless Duct ɸ160 mm ×1 Pc
1. What is the purpose of the Ductless Fume Hood ADDLF-505?
The Ductless Fume Hood ADDLF-505 is designed to protect users from hazardous fumes, vapors, and particulates by filtering air and recirculating clean air back into the lab. Unlike traditional fume hoods, it requires no external ducting, making it ideal for laboratories where installation of ductwork is not feasible. It ensures operator safety by using advanced filtration systems such as activated carbon and HEPA filters.
2. What types of filters are used in the Ductless Fume Hood ADDLF-505?
The Ductless Fume Hood ADDLF-505 typically uses a combination of activated carbon filters for chemical vapors and optional HEPA or ULPA filters for particulates. These filters are selected based on the nature of substances being handled. Activated carbon adsorbs organic fumes, solvents, and mild acids or bases. HEPA filters remove 99.97% of airborne particles ?0.3 microns in size. Regular maintenance and filter replacement are crucial to ensure effective filtration.
3. What are the main benefits of using the Ductless Fume Hood ADDLF-505 in the lab?
The Ductless Fume Hood ADDLF-505 offers flexibility, portability, and ease of installation due to its ductless design. It helps maintain a clean and safe lab environment by filtering contaminants without external ventilation. Its energy efficiency and low maintenance requirements make it cost-effective for many labs. The unit typically includes clear visibility sashes, user-friendly controls, and filter status indicators. It’s a practical solution for labs needing localized, safe, and compliant air filtration.
4. How often do the filters need to be changed in Ductless Fume Hood ADDLF-505?
Filter life depends on the type and frequency of usage as well as the chemicals being handled. Generally, filters should be inspected regularly and replaced every 6 to 12 months, or sooner if saturation is detected. Some models feature filter saturation indicators for real-time monitoring. Using saturated filters reduces the effectiveness and poses health risks. Following the manufacturer’s filter replacement guidelines is essential for safety and compliance.
5. Can the Ductless Fume Hood ADDLF-505 be used for handling all types of chemicals?
No, the Ductless Fume Hood ADDLF-505 is not suitable for all chemicals—particularly highly toxic, explosive, or corrosive substances. It is best used for low to moderate hazard chemicals that can be effectively captured by the installed filter type. Before use, a chemical compatibility assessment should be done to ensure the filters can safely adsorb the vapors generated.
6. What is a Ductless Fume Hood?
A Ductless Fume Hood is a type of extraction system designed to filter air within a laboratory without the need for external ductwork. These uses advanced filtration technology, such as activated carbon and HEPA filters, to capture chemical fumes. They are requiring ventilation systems connected to the outside and return the clean air back into the room.
7. Can Ductless Fume Hoods be used for all chemicals?
While Ductless Fume Hoods are effective for many common chemical applications, they are not suitable for all types of chemicals. Some highly toxic chemicals may require more specialized containment methods. These are important to consult the manufacturer’s guidelines for compatibility with specific chemicals. These produces gases that cannot be filtered by standard carbon, a ducted system is necessary.
| Velocity | 0.4 to 0.6 m/s |
| Filter Modular | 4 |
| Air Pressure | 960 Pa |
| External Dimension (L×B×H) | 1000×650×1900 mm |
| Internal Dimension (L×B×H) | 920×620×700 mm |
| Air treatment | 220 to1200 m³/h |
| External Dimension (L×B×H) | 1200×650×1900 mm |
| Internal Dimension (L×B×H) | 1125×620×700 mm |
| Air treatment | 220 to1200 m³/h |
| Velocity: | 0.3 to 0.6 m/s |
| Power Supply: | AC220V/50Hz/0.8KW |
| Fluorescent Lamp: | 28 W × 1 |
| External Dimensions (W× D × H): | 950 × 730 × 1150 mm |
| Internal Dimensions (W× D × H): | 1200 × 1000 × 2250 mm |
| Surface Wind Speed: | 0.3 ~ 0.6 m/s |
| Velocity: | 0.3 to 0.6 m/s |
| Power Supply: | AC220V/50Hz/0.6KW |
| Fluorescent Lamp: | 28 W × 1 |
| External Dimension (L×B×H): | 1000×600×1000 mm |
| Internal Dimension (L×B×H): | 960×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 800×650×1050 mm |
| Internal Dimension (L×B×H): | 690×530×740 mm |
| Air Volume: | 1200 m³/h |
| External Dimension (L×B×H): | 1200×800×1500 mm |
| Internal Dimension (L×B×H): | 950×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×650×1000 mm |
| Internal Dimension (L×B×H): | 1000×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×650×1000 mm |
| Internal Dimension (L×B×H): | 1300×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×650×1050 mm |
| Internal Dimension (L×B×H): | 1390×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×600×1000 mm |
| Internal Dimension (L×B×H): | 1160×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×650×1050 mm |
| Internal Dimension (L×B×H): | 1090×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 650 × 650 × 1050 mm |
| Internal Dimension (L×B×H): | 540 × 530 × 740 mm |
| Air Volume: | 1200 m³/h |
| External Dimension (L×B×H): | 1000×650×1000 mm |
| Internal Dimension (L×B×H): | 800×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×800×1500 mm |
| Internal Dimension (L×B×H): | 1250×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 650×600×1000 mm |
| Internal Dimension (L×B×H): | 610×580×650 mm |
| Air Volume: | 420 m³/h |
| External Dimension (L×B×H): | 800×600×1000 mm |
| Internal Dimension (L×B×H): | 760×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 800×650×1000 mm |
| Internal Dimension (L×B×H): | 600×530×750 mm |
| Air Volume: | 420 m³/h |
| External Dimension (L×B×H): | 1500×600×1000 mm |
| Internal Dimension (L×B×H): | 1460×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 650×600×1000 mm |
| Internal Dimension (L×B×H): | 610×580×650 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1800×800×1500 mm |
| Internal Dimension (L×B×H): | 1550×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1000×650×1050 mm |
| Internal Dimension (L×B×H): | 890×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 890×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1390×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×800×2350 mm |
| Internal Dimension (L×B×H): | 1250×630×1150 mm |
| Maximum Opening: | 650mm |
| External Dimension (W×D×H): | 1500 × 850 × 2350 mm |
| Internal Dimension (W×D×H): | 1260 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H): | 1500 × 800 × 850 mm |
| External Dimension (L×B×H): | 1800×800×2350 mm |
| Internal Dimension (L×B×H): | 1550×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1000×650×1900 mm |
| Internal Dimension (L×B×H): | 800×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1500×650×1900 mm |
| Internal Dimension (L×B×H): | 1300×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (W × D × H): | 1040 × 800 × 2200 mm |
| Internal Dimension (W × D × H): | 790× 670 × 1050mm |
| Maximum Opening: | 520 mm |
| External Dimension (W×D×H): | 1200 × 850 × 2350 mm |
| Internal Dimension (W×D×H): | 960 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H): | 1200 × 800 × 850 mm |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1000×530×750 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 1200×650×1900 mm |
| Internal Dimension (L×B×H): | 1090×530×740 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (W×D×H): | 1800 × 850 × 2350 mm |
| Internal Dimension (W×D×H): | 1560 × 680 × 1150 mm |
| Base Cabinet Dimension (W×D×H): | 1800 × 800 × 850 mm |
| External Dimension (L×B×H): | 1200×800×2350 mm |
| Internal Dimension (L×B×H): | 950×630×1150 mm |
| Air Volume: | 1850 m³/h |
| External Dimension (L×B×H): | 800×650×1900 mm |
| Internal Dimension (L×B×H): | 690×530×740 mm |
| Air Volume: | 420 m³/h |
| External Dimension (L×B×H): | 800×650×1900 mm |
| Internal Dimension (L×B×H): | 600×530×750 mm |
| Air Volume: | 420 m³/h |
| External Dimensions (W × D × H): | 1500 × 850 × 2350 mm |
| Internal Dimension (W × D × H): | 1300 × 590 × 900 mm |
| Air Volume: | 2300 m³/h |