We offer Ductless Fume Hood ADDLF-502 fan power ranging from 48 W to 110 W, ensuring efficient airflow, while maintaining low energy consumption. It features a clear front sash for visibility and protection. The modular construction allows for easy filter replacement and maintenance. This unit recirculates clean air back into the laboratory environment, ensuring user safety. Our Ductless Fume Hood is used in chemical labs, pharmaceuticals and forensics, to safely filter hazardous fumes.
External Dimension (L×B×H) | 1000×650×1900 mm |
Internal Dimension (L×B×H) | 920×620×700 mm |
Air treatment | 220 to1200 m³/h |
Noise | 8db |
Fan Power | 48 W to 110 W |
LED power | 6 W to 10 W |
Main Body | 1.0 mm thick cold-rolled steel with epoxy powder coating |
Work Top | 12.7 mm solid physiochemical board; ceramic or stainless-steel optional worktop |
Power supply | 220 V |
Power consumption | 2000 W |
Dimensions (L×B×H) | 116×88×120 mm |
Gross Weight | 180 Kg |
Our Ductless Fume Hood ADDLF-502 is used in biotechnology labs, chemical analysis and clinical research to provide localized fume filtration and protect users from harmful vapours.
10 A Socket 1 Pc Fan 1 Pc LED Light 1 Pc Duct 1 Pc LCD touch screen 1 Pc UV lamp 1 Pc Universal caster 1 Pc
Ductless Duct ɸ160 mm ×1 Pc
1. What is the primary function of the Ductless Fume Hood ADDLF-502?
The Ductless Fume Hood ADDLF-502 is designed to safely filter and recirculate air contaminated with chemical fumes, vapors, or particulates. It operates without external ducting, making it suitable for laboratories with space or ventilation limitations. The unit draws in contaminated air, passes it through activated carbon and HEPA filters, and releases clean air back into the room. This protects users from hazardous substances during handling and experimentation.
2. Does the Ductless Fume Hood ADDLF-502 require any special installation?
No, the Ductless Fume Hood ADDLF-502 is a plug-and-play system that does not require external ductwork or complex installation. It is a self-contained unit, which makes it easy to install on benchtops in various laboratory environments. Users only need a standard power supply to operate the hood. Its portability and minimal installation needs are major advantages. This allows for flexibility and cost savings in lab setup.
3. What types of filters are used in the Ductless Fume Hood ADDLF-502?
The Ductless Fume Hood ADDLF-502 uses high-quality activated carbon filters and optional HEPA filters depending on the application. Activated carbon effectively absorbs chemical fumes, while HEPA filters trap particulate matter. The filter configuration can be customized based on the types of substances being handled. These filters are designed for easy replacement and maintenance. Regular filter monitoring ensures optimal performance and user safety.
4. How often should the filters be replaced in the Ductless Fume Hood ADDLF-502?
Filter replacement depends on the frequency of use and the type of chemicals handled. Typically, filters need to be changed every 6 to 12 months for optimal performance. The unit is equipped with filter saturation indicators to alert users when it’s time for replacement. Routine checks and maintenance ensure continued safe operation. Following manufacturer guidelines is essential to maintain effectiveness and safety.
5. In which environments is the Ductless Fume Hood ADDLF-502 most commonly used?
The Ductless Fume Hood ADDLF-502 is widely used in chemical laboratories, educational institutions, forensic labs, and pharmaceutical research settings. It’s especially suitable for environments where external ducting is impractical. Its compact design and efficient filtration make it ideal for benchtop use. It is also used in cosmetic and electronics testing labs. Overall, the unit ensures safe air handling while offering operational flexibility.
6. What is a Ductless Fume Hood?
A Ductless Fume Hood is a type of extraction system designed to filter air within a laboratory without the need for external ductwork. These uses advanced filtration technology, such as activated carbon and HEPA filters, to capture chemical fumes. They are requiring ventilation systems connected to the outside and return the clean air back into the room.
7. Can Ductless Fume Hoods be used for all chemicals?
While Ductless Fume Hoods are effective for many common chemical applications, they are not suitable for all types of chemicals. Some highly toxic chemicals may require more specialized containment methods. These are important to consult the manufacturer’s guidelines for compatibility with specific chemicals. These produces gases that cannot be filtered by standard carbon, a ducted system is necessary.
External Dimension (L×B×H) | 725×620×700 mm |
Internal Dimension (L×B×H) | 800×650×1900 mm |
Air treatment | 220 to1200 m³/h |
USD 2,400.00
External Dimension (L×B×H) | 1200×650×1900 mm |
Internal Dimension (L×B×H) | 1125×620×700 mm |
Air treatment | 220 to1200 m³/h |
USD 2,800.00
Velocity: | 0.3 to 0.6 m/s |
Power Supply: | AC220V/50Hz/0.4KW |
Fluorescent Lamp: | 21 W × 1 |
Velocity: | 0.3 to 0.6 m/s |
Power Supply: | AC220V/50Hz/0.6KW |
Fluorescent Lamp: | 28 W × 1 |
Velocity: | 0.3 to 0.6 m/s |
Power Supply: | AC220V/50Hz/0.8KW |
Fluorescent Lamp: | 28 W × 1 |
External Dimension (L×B×H): | 1800×800×1500 mm |
Internal Dimension (L×B×H): | 1550×630×1150 mm |
Air Volume: | 1850 m³/h |
USD 1,310.00
External Dimension (L×B×H): | 1200×800×1500 mm |
Internal Dimension (L×B×H): | 950×630×1150 mm |
Air Volume: | 1850 m³/h |
USD 1,070.00
External Dimension (L×B×H): | 800×650×1000 mm |
Internal Dimension (L×B×H): | 600×530×750 mm |
Air Volume: | 420 m³/h |
USD 700.00
External Dimension (L×B×H): | 1000×650×1000 mm |
Internal Dimension (L×B×H): | 800×530×750 mm |
Air Volume: | 1850 m³/h |
USD 760.00
External Dimension (L×B×H): | 1500×650×1000 mm |
Internal Dimension (L×B×H): | 1300×530×750 mm |
Air Volume: | 1850 m³/h |
USD 900.00
External Dimension (L×B×H): | 1500×600×1000 mm |
Internal Dimension (L×B×H): | 1460×580×650 mm |
Air Volume: | 1850 m³/h |
USD 1,120.00
External Dimension (L×B×H): | 1200×650×1050 mm |
Internal Dimension (L×B×H): | 1090×530×740 mm |
Air Volume: | 1850 m³/h |
USD 1,040.00
External Dimension (L×B×H): | 1200×650×1000 mm |
Internal Dimension (L×B×H): | 1000×530×750 mm |
Air Volume: | 1850 m³/h |
USD 800.00
External Dimension (L×B×H): | 1500×650×1050 mm |
Internal Dimension (L×B×H): | 1390×530×740 mm |
Air Volume: | 1850 m³/h |
USD 1,120.00
External Dimension (L×B×H): | 800×600×1000 mm |
Internal Dimension (L×B×H): | 760×580×650 mm |
Air Volume: | 1850 m³/h |
USD 890.00
External Dimension (L×B×H): | 1000×600×1000 mm |
Internal Dimension (L×B×H): | 960×580×650 mm |
Air Volume: | 1850 m³/h |
USD 960.00
External Dimension (L×B×H): | 650×600×1000 mm |
Internal Dimension (L×B×H): | 610×580×650 mm |
Air Volume: | 1850 m³/h |
USD 700.00
External Dimension (L×B×H): | 1500×800×1500 mm |
Internal Dimension (L×B×H): | 1250×630×1150 mm |
Air Volume: | 1850 m³/h |
USD 1,180.00
External Dimension (L×B×H): | 650×600×1000 mm |
Internal Dimension (L×B×H): | 610×580×650 mm |
Air Volume: | 420 m³/h |
USD 700.00
External Dimension (L×B×H): | 1000×650×1050 mm |
Internal Dimension (L×B×H): | 890×530×740 mm |
Air Volume: | 1850 m³/h |
USD 960.00
External Dimension (L×B×H): | 800×650×1050 mm |
Internal Dimension (L×B×H): | 690×530×740 mm |
Air Volume: | 420 m³/h |
USD 890.00
External Dimension (L×B×H): | 1200×600×1000 mm |
Internal Dimension (L×B×H): | 1160×580×650 mm |
Air Volume: | 1850 m³/h |
USD 1,040.00
External Dimension (L×B×H): | 650×650×1000 mm |
Internal Dimension (L×B×H): | 450×530×750 mm |
Air Volume: | 420 m³/h |
USD 630.00
External Dimension (W×D×H): | 1500 × 850 × 2350 mm |
Internal Dimension (W×D×H): | 1260 × 680 × 1150 mm |
Base Cabinet Dimension (W×D×H): | 1500 × 800 × 850 mm |
USD 2,900.00
External Dimension (L×B×H): | 1500×800×2350 mm |
Internal Dimension (L×B×H): | 1250×630×1150 mm |
Air Volume: | 1850 m³/h |
USD 1,530.00
External Dimension (W×D×H): | 1800 × 850 × 2350 mm |
Internal Dimension (W×D×H): | 1560 × 680 × 1150 mm |
Base Cabinet Dimension (W×D×H): | 1800 × 800 × 850 mm |
USD 3,130.00
External Dimension (L×B×H): | 1800×800×2350 mm |
Internal Dimension (L×B×H): | 1550×630×1150 mm |
Air Volume: | 1850 m³/h |
USD 1,680.00
External Dimension (W×D×H): | 1200 × 850 × 2350 mm |
Internal Dimension (W×D×H): | 960 × 680 × 1150 mm |
Base Cabinet Dimension (W×D×H): | 1200 × 800 × 850 mm |
USD 2,570.00
External Dimension (L×B×H): | 1200×800×2350 mm |
Internal Dimension (L×B×H): | 950×630×1150 mm |
Air Volume: | 1850 m³/h |
USD 1,390.00
External Dimension (L×B×H): | 800×650×1900 mm |
Internal Dimension (L×B×H): | 600×530×750 mm |
Air Volume: | 420 m³/h |
USD 1,490.00
External Dimension (L×B×H): | 1200×650×1900 mm |
Internal Dimension (L×B×H): | 1000×530×750 mm |
Air Volume: | 1850 m³/h |
USD 1,490.00
External Dimension (L×B×H): | 1000×650×1900 mm |
Internal Dimension (L×B×H): | 800×530×750 mm |
Air Volume: | 1850 m³/h |
USD 1,490.00
External Dimension (L×B×H): | 1500×650×1900 mm |
Internal Dimension (L×B×H): | 1300×530×750 mm |
Air Volume: | 1850 m³/h |
USD 790.00
External Dimension (L×B×H): | 1500×650×1900 mm |
Internal Dimension (L×B×H): | 1390×530×740 mm |
Air Volume: | 1850 m³/h |
USD 1,330.00
External Dimension (L×B×H): | 1200×650×1900 mm |
Internal Dimension (L×B×H): | 1090×530×740 mm |
Air Volume: | 1850 m³/h |
USD 1,400.00
External Dimension (L×B×H): | 1000×650×1900 mm |
Internal Dimension (L×B×H): | 890×530×740 mm |
Air Volume: | 1850 m³/h |
USD 1,320.00
External Dimension (L×B×H): | 800×650×1900 mm |
Internal Dimension (L×B×H): | 690×530×740 mm |
Air Volume: | 420 m³/h |
USD 1,240.00