Single Channel Variable Pipette ADCVP-516

Single Channel Variable Pipette ADCVP-516

Single Channel Variable Pipette ADCVP-516 has an accuracy of ±1.50 % at 1000 µl for ensuring reproducible results in laboratory experiments. It offers accurate liquid handling with digital volume adjustment for enhanced results. Features multiple pipetting modes for versatility in various tasks. This unit is designed ergonomically, with a lightweight construction that ensures comfort during extended use. Our Single Channel Variable Pipette is used in research, clinical diagnostics and biotechnology for accurate liquid handling.


Volume Range 100 to 1000 µl
Increment 2 µl
Test Volume 100µl
500µl
1000 µl
Accuracy ±1.50 % at 1000 µl
±0.80 % at 500 µl
±0.80 % at 100 µl
Precision ±0.40 % at 1000 µl
±0.30 % at 500 µl
±0.20 % at 100 µl
Channel 1
Gross Weight 14 Kg
Dimensions (L×B×H) 505×410×317 mm
  • Wide volume range
  • Precise volume dispensing
  • Advanced calibration system
  • Hands-free tip ejection
  • Clear digital display

Our Single Channel Variable Pipette ADCVP-516 is used in various fields, including clinical diagnostics, forensic science, and education, for accurate liquid handling and precise measurements. 

Single Channel Variable Pipette ADCVP-513|Increment:2 µl|Volume Range:100µl 500µl 1000µl
Single Channel Variable Pipette ADCVP-516|Wide volume range|Precise volume dispensing

Frequently Asked Questions of Single Channel Variable Pipette ADCVP-516

1. What is a Single Channel Variable Pipette and how does it work?

A Single Channel Variable Pipette is a laboratory instrument used to accurately measure and transfer small volumes of liquids. It has a single dispensing channel and allows users to adjust the volume within a specific range, such as 2–20 µL or 100–1000 µL. The volume is selected using a dial or rotating knob on the pipette. It works by creating a vacuum with a piston that aspirates and dispenses liquid through a disposable tip.

2. How to calibrate a Single Channel Variable Pipette?

Calibration ensures the pipette dispenses the correct volume and is typically done using distilled water and a precision balance. The pipette is set to a target volume, and water is pipetted multiple times into a pre-weighed container. The weight is converted to volume considering water density at room temperature. If the dispensed volume differs from the set volume beyond acceptable tolerance, adjustments are made.

3. What are the main parts of a Single Channel Variable Pipette?

The main parts include the plunger button, volume adjustment dial, tip ejector button, shaft, and disposable tip cone. The plunger controls aspiration and dispensing of liquid. The volume dial sets the desired liquid volume to be pipetted. The tip ejector allows safe and hands-free disposal of used tips. The shaft holds the pipette tip securely during operation.

4. What is the correct technique for pipetting liquids using a Single Channel Variable Pipette?

Start by setting the desired volume using the dial and securely attaching a compatible pipette tip. Press the plunger to the first stop before inserting it into the liquid. Slowly release the plunger to aspirate the liquid, then move the pipette to the receiving vessel. Dispense by pressing the plunger smoothly to the first stop, then to the second stop to expel any residual liquid.

5. What are the sources of error while using a Single Channel Variable Pipette?

Errors can occur due to incorrect pipetting technique, such as not holding the pipette vertically or releasing the plunger too quickly. Using damaged or incompatible tips can also cause leakage or inaccurate measurements. Environmental factors like temperature and humidity can affect liquid volume, especially with small volumes. Inconsistent pre-wetting or failure to calibrate regularly also contributes to errors.

Similar Products of Single Channel Variable Pipette

Volume Range 1 to 10 µl
Increment 0.1 µl
Test Volume 10 µl
5µl
1 µl
Volume Range 20 to 200 µl
Increment 1 µl
Test Volume 200µl
100µl
20 µl
Volume Range 100 to 1000 µl
Increment 5 µl
Test Volume 1000 µl
500µl
100 µl
Volume Range 0.5 to 5 µl
Increment 20 µl
Test Volume 1000 µl
2500 µl
5000 µl

Electronic Pipette

Electronic Pipette ADEP-501
Volume Range:0.1 to 10 µl
Increment:0.01 µl
Test Volume:10 µl <br/> 5 µl <br/> 1 µl
Electronic Pipette ADEP-503
Volume Range:10 to 300µl
Increment:0.20µl
Test Volume:30µl<br>150µl<br>300µl
Electronic Pipette ADEP-506
Volume Range:500 to 10000 µl
Increment:10.00 µl
Test Volume:10000 µl <br/> 5000 µl <br/> 1000 µl
Electronic Pipette ADEP-505
Volume Range:100to5000µl
Increment:5.00µl
Test Volume:5000µl<br/> 2500µl<br/> 500µl
Electronic Pipette ADEP-504
Volume Range:50-1000µl
Increment:1.00µl
Test Volume:100µl<br/> 500µl<br/> 1000µl
Electronic Pipette ADEP-502
Volume Range:5 to 120µl
Increment:0.10 µl
Test Volume:12 µl<br/> 60 µl<br/> 120 µl

Mini Fixed Volume Pipette

Mini Fixed Volume Pipette ADFVP-503
Volume Range:20µl
Accuracy:±1.0% at 20µl
Precision:±0.5% at 20µl
Mini Fixed Volume Pipette ADFVP-502
Volume Range:10µl
Accuracy:±1.2% at 10µl
Precision:±0.8% at 10µl
Mini Fixed Volume Pipette ADFVP-506
Volume Range:75µl
Accuracy:±0.8% at 75µl
Precision :±0.3% at 75µl
Mini Fixed Volume Pipette ADFVP-504
Volume Range:30µl
Accuracy:±1.0% at 30µl
Precision :±0.4% at 30µl
Mini Fixed Volume Pipette ADFVP-501
Volume Range:5µl
Accuracy:±2.5% at 5µl
Precision :±1.5% at 5µl
Mini Fixed Volume Pipette ADFVP-509
Volume Range:300µl
Accuracy:±0.8% at 300µl
Precision:±0.3% at 300µl
Mini Fixed Volume Pipette ADFVP-507
Volume Range:100µl
Accuracy:±0.8% at 100µl
Precision:±0.3% at 100µl
Mini Fixed Volume Pipette ADFVP-508
Volume Range:200µl
Accuracy:±0.8% at 200µl
Precision:±0.3% at 200µl
Mini Fixed Volume Pipette ADFVP-505
Volume Range:50µl
Accuracy:±1% at 50µl
Precision:±0.4% at 50µl

Multi-Channel Pipette

Multi-Channel Pipette ADMCP-510
Volume Range:5 to 50 µl
Increment:0.5 µl
Test Volume:50 µl<br/> 25 µl<br/> 5 µl
Multi-Channel Pipette ADMCP-506
Volume Range:30 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 30 µl
Multi-Channel Pipette ADMCP-505
Volume Range:20 to 200 µl
Increment:1 µl
Test Volume:200 µl<br/> 100 µl<br/> 20 µl
Multi-Channel Pipette ADMCP-501
Volume Range:0.5 to 10 µl
Increment:0.1 µl
Test Volume:10 µl<br/> 5 µl<br/> 1 µl
Multi-Channel Pipette ADMCP-509
Volume Range:2 to 20 µl
Increment:0.5 µl
Test Volume:20 µl<br/> 10 µl<br/> 2 µl
Multi-Channel Pipette ADMCP-512
Volume Range:20 to 200 µl
Increment:1 µl
Test Volume:200 µl<br/> 100 µl<br/> 10µl
Multi-Channel Pipette ADMCP-504
Volume Range:10 to 100 µl
Increment:1 µl
Test Volume:100 µl<br/> 50 µl<br/> 10 µl
Multi-Channel Pipette ADMCP-508
Volume Range:0.5 to 10 µl
Increment:0.1 µl
Test Volume:10 µl<br/> 5 µl<br/> 1 µl
Multi-Channel Pipette ADMCP-514
Volume Range:50 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 50µl
Multi-Channel Pipette ADMCP-513
Volume Range:30 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 30µl
Multi-Channel Pipette ADMCP-503
Volume Range:5 to 50 µl
Increment:0.5 µl
Test Volume:50 µl<br/> 25 µl<br/> 5 µl
Multi-Channel Pipette ADMCP-511
Volume Range:10 to 100 µl
Increment:1 µl
Test Volume:100 µl<br/> 50 µl<br/> 2 µl
Multi-Channel Pipette ADMCP-507
Volume Range:50 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 50 µl
Multi-Channel Pipette ADMCP-502
Volume Range:2 to 20 µl
Increment:0.5 µl
Test Volume:20 µl<br/> 10 µl<br/> 2 µl

Pipette With Switch

Pipette With Switch ADPWS-506
Volume Range:10 to 1000µl
Increment:5µl
Test Volume:1000µl <br/> 500µl <br/> 100µl
Pipette With Switch ADPWS-504
Volume Range:10 to 100µl
Increment:1µl
Test Volume:100µl <br/> 50µl <br/> 10µl
Pipette With Switch ADPWS-507
Volume Range:1 to 5µl
Increment:50µl
Test Volume:5000µl <br/> 2500µl <br/> 1000µl
Pipette With Switch ADPWS-501
Volume Range:0.5 to 10µl
Increment:0.1µl
Test Volume:10µl <br/> 5µl <br/> 1µl
Pipette With Switch ADPWS-502
Volume Range:2 to 20µl
Increment:0.5µl
Test Volume:20µl <br/> 10µl <br/> 2µl
Pipette With Switch ADPWS-505
Volume Range:20 to 200µl
Increment:1µl
Test Volume:200µl <br/> 100µl <br/> 20µl
Pipette With Switch ADPWS-503
Volume Range:5 to 50µl
Increment:0.5µl
Test Volume:50µl <br/> 25µl <br/> 5µl

Fixed Volume Pipette

Fixed Volume Pipette ADFPT-504
Volume:25µl
Accuracy:±3.00µl
Precision:≤1.50µl
Fixed Volume Pipette ADFPT-506
Volume:100µl
Accuracy:±2.00µl
Precision:≤1.00µl
Fixed Volume Pipette ADFPT-505
Volume:50µl
Accuracy:±3.00µl
Precision:≤1.50µl
Fixed Volume Pipette ADFPT-502
Volume:10µl
Accuracy:±4.80µl
Precision:≤2.50µl
Fixed Volume Pipette ADFPT-501
Volume:5µl
Accuracy:±8.00µl
Precision:≤5.00µl
Fixed Volume Pipette ADFPT-503
Volume:20µl
Accuracy:±3.00µl
Precision:≤1.50µl