Single Channel Variable Pipette ADCVP-511

Single Channel Variable Pipette ADCVP-511

Single Channel Variable Pipette ADCVP-511 comes with a volume range of 0.2 to 2 µl for handling very small liquid capacity with high precision. It is compatible with standard universal tips, allowing for cost-effective operation. This unit allows for uniform sample processing, making it ideal for time-sensitive assays. The smooth operation and reliable sealing enhance reproducibility across repeated tasks. Our Multi-Channel Pipette is used in life sciences and clinical fields for microplate filling and high-throughput screening. 

USD 510.00
Volume Range 0.2 to 2 µl
Increment 0.002 µl
Test Volume 0.2 µl
0.5µl
2 µl
Accuracy ±12.00 % at 2 µl
±5.00 % at 2 µl
±1.50 % at 2 µl
Precision ≤6.00 % at 2 µl
≤2.50 % at 2 µl
≤0.70 % at 2 µl
Channel 1
Gross Weight 13 Kg
Dimensions (L×B×H) 505×410×317 mm
  • Volume lock mechanism
  • Autoclavable components
  • Easy tip ejection
  • Ergonomic design
  • User-friendly

Our Single Channel Variable Pipette ADCVP-511 is used for tasks such as enzyme assays, cell culture media transfer and protein quantification, making it essential in microbiology, biotechnology and forensic science labs. 

Frequently Asked Questions of Single Channel Variable Pipette ADCVP-511

1. What is a Single Channel Variable Pipette and how does it work?

A Single Channel Variable Pipette is a laboratory tool used to accurately measure and transfer small volumes of liquid, typically ranging from microliters to milliliters. It consists of a plunger, volume adjustment knob, and a disposable tip. The user can set the desired volume by rotating the adjustment knob. When the plunger is pressed and released, it creates a vacuum to draw the liquid into the tip. It ensures precision and accuracy in liquid handling, especially in molecular biology and chemistry labs.

2. How to calibrate a Single Channel Variable Pipette?

To calibrate a pipette, it is tested using a gravimetric method where distilled water is pipetted and weighed. The actual volume is calculated based on the weight and compared with the set volume. If discrepancies are found, the pipette is adjusted using a calibration tool or screw. Calibration ensures that the pipette dispenses accurate volumes. Regular calibration maintains the reliability and consistency of experimental results.

3. What is the correct technique for using a Single Channel Variable Pipette?

The user should set the desired volume using the adjustment knob, attach a clean tip firmly, and press the plunger to the first stop before immersing the tip into the liquid. Then release the plunger slowly to aspirate the liquid. For dispensing, the tip is placed against the wall of the receiving container, and the plunger is pressed to the first stop to release the liquid, then to the second stop to expel any residual liquid.

4. Can a Single Channel Pipette be used for viscous liquids?

Yes, but extra care is needed when pipetting viscous liquids like glycerol or oil. A slower plunger motion and reverse pipetting technique can improve accuracy. Using wide-bore tips can also help with thicker fluids. Calibration should be adjusted if viscous liquids are frequently used. Standard pipetting techniques may lead to under-delivery with such liquids.

5. How to clean and maintain a Single Channel Variable Pipette?

Regular cleaning involves wiping the exterior with 70% ethanol and occasionally removing and cleaning the piston and tip cone. Internal components can be cleaned with mild detergent or deionized water if contaminated. Autoclavable models allow parts like the lower assembly to be sterilized in an autoclave. Always ensure the pipette is dry before reassembly.

Similar Products of Single Channel Variable Pipette

Volume Range 5 to 50 µl
Increment 0.5 µl
Test Volume 50 µl
25 µl
5 µl

USD 310.00

Volume Range 1 to 10 µl
Increment 0.1 µl
Test Volume 10 µl
5µl
1 µl

USD 310.00

Volume Range 1 to 10 µl
Increment 20 µl
Test Volume 1 µl
5µl
10 µl

USD 510.00

Volume Range 30to 300 µl
Increment 5 µl
Test Volume 300 µl
150 µl
30 µl

USD 310.00

Electronic Pipette

Electronic Pipette ADEP-506
Volume Range:500 to 10000 µl
Increment:10.00 µl
Test Volume:10000 µl <br/> 5000 µl <br/> 1000 µl

USD 700.00

Electronic Pipette ADEP-501
Volume Range:0.1 to 10 µl
Increment:0.01 µl
Test Volume:10 µl <br/> 5 µl <br/> 1 µl

USD 700.00

Electronic Pipette ADEP-502
Volume Range:5 to 120µl
Increment:0.10 µl
Test Volume:12 µl<br/> 60 µl<br/> 120 µl

USD 700.00

Electronic Pipette ADEP-504
Volume Range:50-1000µl
Increment:1.00µl
Test Volume:100µl<br/> 500µl<br/> 1000µl

USD 700.00

Electronic Pipette ADEP-505
Volume Range:100to5000µl
Increment:5.00µl
Test Volume:5000µl<br/> 2500µl<br/> 500µl

USD 630.00

Electronic Pipette ADEP-503
Volume Range:10 to 300µl
Increment:0.20µl
Test Volume:30µl<br>150µl<br>300µl

USD 700.00

Mini Fixed Volume Pipette

Mini Fixed Volume Pipette ADFVP-505
Volume Range:50µl
Accuracy:±1% at 50µl
Precision:±0.4% at 50µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-507
Volume Range:100µl
Accuracy:±0.8% at 100µl
Precision:±0.3% at 100µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-501
Volume Range:5µl
Accuracy:±2.5% at 5µl
Precision :±1.5% at 5µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-506
Volume Range:75µl
Accuracy:±0.8% at 75µl
Precision :±0.3% at 75µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-502
Volume Range:10µl
Accuracy:±1.2% at 10µl
Precision:±0.8% at 10µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-504
Volume Range:30µl
Accuracy:±1.0% at 30µl
Precision :±0.4% at 30µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-509
Volume Range:300µl
Accuracy:±0.8% at 300µl
Precision:±0.3% at 300µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-508
Volume Range:200µl
Accuracy:±0.8% at 200µl
Precision:±0.3% at 200µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-503
Volume Range:20µl
Accuracy:±1.0% at 20µl
Precision:±0.5% at 20µl

USD 310.00

Multi-Channel Pipette

Multi-Channel Pipette ADMCP-505
Volume Range:20 to 200 µl
Increment:1 µl
Test Volume:200 µl<br/> 100 µl<br/> 20 µl

USD 340.00

Multi-Channel Pipette ADMCP-506
Volume Range:30 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 30 µl

USD 340.00

Multi-Channel Pipette ADMCP-513
Volume Range:30 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 30µl

USD 350.00

Multi-Channel Pipette ADMCP-502
Volume Range:2 to 20 µl
Increment:0.5 µl
Test Volume:20 µl<br/> 10 µl<br/> 2 µl

USD 340.00

Multi-Channel Pipette ADMCP-501
Volume Range:0.5 to 10 µl
Increment:0.1 µl
Test Volume:10 µl<br/> 5 µl<br/> 1 µl

USD 340.00

Multi-Channel Pipette ADMCP-507
Volume Range:50 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 50 µl

USD 340.00

Multi-Channel Pipette ADMCP-508
Volume Range:0.5 to 10 µl
Increment:0.1 µl
Test Volume:10 µl<br/> 5 µl<br/> 1 µl

USD 350.00

Multi-Channel Pipette ADMCP-509
Volume Range:2 to 20 µl
Increment:0.5 µl
Test Volume:20 µl<br/> 10 µl<br/> 2 µl

USD 350.00

Multi-Channel Pipette ADMCP-504
Volume Range:10 to 100 µl
Increment:1 µl
Test Volume:100 µl<br/> 50 µl<br/> 10 µl

USD 340.00

Multi-Channel Pipette ADMCP-511
Volume Range:10 to 100 µl
Increment:1 µl
Test Volume:100 µl<br/> 50 µl<br/> 2 µl

USD 350.00

Multi-Channel Pipette ADMCP-503
Volume Range:5 to 50 µl
Increment:0.5 µl
Test Volume:50 µl<br/> 25 µl<br/> 5 µl

USD 340.00

Multi-Channel Pipette ADMCP-512
Volume Range:20 to 200 µl
Increment:1 µl
Test Volume:200 µl<br/> 100 µl<br/> 10µl

USD 350.00

Multi-Channel Pipette ADMCP-510
Volume Range:5 to 50 µl
Increment:0.5 µl
Test Volume:50 µl<br/> 25 µl<br/> 5 µl

USD 350.00

Multi-Channel Pipette ADMCP-514
Volume Range:50 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 50µl

USD 350.00

Pipette With Switch

Pipette With Switch ADPWS-505
Volume Range:20 to 200µl
Increment:1µl
Test Volume:200µl <br/> 100µl <br/> 20µl

USD 590.00

Pipette With Switch ADPWS-506
Volume Range:10 to 1000µl
Increment:5µl
Test Volume:1000µl <br/> 500µl <br/> 100µl

USD 590.00

Pipette With Switch ADPWS-507
Volume Range:1 to 5µl
Increment:50µl
Test Volume:5000µl <br/> 2500µl <br/> 1000µl

USD 590.00

Pipette With Switch ADPWS-504
Volume Range:10 to 100µl
Increment:1µl
Test Volume:100µl <br/> 50µl <br/> 10µl

USD 590.00

Pipette With Switch ADPWS-501
Volume Range:0.5 to 10µl
Increment:0.1µl
Test Volume:10µl <br/> 5µl <br/> 1µl

USD 590.00

Pipette With Switch ADPWS-502
Volume Range:2 to 20µl
Increment:0.5µl
Test Volume:20µl <br/> 10µl <br/> 2µl

USD 590.00

Pipette With Switch ADPWS-503
Volume Range:5 to 50µl
Increment:0.5µl
Test Volume:50µl <br/> 25µl <br/> 5µl

USD 590.00

Fixed Volume Pipette

Fixed Volume Pipette ADFPT-506
Volume:100µl
Accuracy:±2.00µl
Precision:≤1.00µl

USD 240.00

Fixed Volume Pipette ADFPT-504
Volume:25µl
Accuracy:±3.00µl
Precision:≤1.50µl

USD 240.00

Fixed Volume Pipette ADFPT-503
Volume:20µl
Accuracy:±3.00µl
Precision:≤1.50µl

USD 240.00

Fixed Volume Pipette ADFPT-502
Volume:10µl
Accuracy:±4.80µl
Precision:≤2.50µl

USD 240.00

Fixed Volume Pipette ADFPT-505
Volume:50µl
Accuracy:±3.00µl
Precision:≤1.50µl

USD 240.00

Fixed Volume Pipette ADFPT-501
Volume:5µl
Accuracy:±8.00µl
Precision:≤5.00µl

USD 240.00