Single Channel Variable Pipette ADCVP-517 comes with a volume range of 0.5 to 5 µl for handling very small liquid capacity with high precision. It includes a tip ejector, that allows for quick tip disposal after each use. The ergonomic design provides comfort and reduces hand strain during extended pipetting. This unit works with standard pipette tips, providing flexibility for various lab tasks. Our Single Channel Variable Pipette is used in clinics, forensics and academics for precise liquid measurement.


Volume Range 0.5 to 5 µl
Increment 20 µl
Test Volume 1000 µl
2500 µl
5000 µl
Accuracy ±1.00 % at 5000 µl
±0.60 % at 2500 µl
±0.60 % at 1000 µl
Precision ≤0.40 % at 5000 µl
≤0.30 % at 2500 µl
≤0.20 % at 1000 µl
Channel 1
Gross Weight 14.4 kg
Dimensions (L×B×H) 505×410×317 mm
  • Autoclavable components
  • Volume lock mechanism
  • Ergonomic design
  • User-friendly
  • Easy tip ejection

Our Single Channel Variable Pipette ADCVP-517 is widely used in molecular biology, clinical diagnostics and pharmaceuticals for precise and efficient liquid handling.

Single Channel Variable Pipette ADCVP-517:Increment:20 µl|Test Volume:1000 µl 2500 µl 5000 µl
Single Channel Variable Pipette ADCVP-517:Volume lock mechanism|Ergonomic design

Frequently Asked Questions of Single Channel Variable Pipette ADCVP-517

1. How often should a Single Channel Variable Pipette be calibrated and why?

A Single Channel Variable Pipette should ideally be calibrated every 3 to 6 months, depending on its usage and the lab’s quality standards. Frequent calibration ensures the pipette maintains its accuracy and complies with regulatory requirements. Over time, wear and tear in internal parts like the piston or seals can affect performance. Regular calibration helps detect such issues early.

2. What are the sources of error while using a Single Channel Variable Pipette?

Errors can occur due to incorrect pipetting technique, such as not holding the pipette vertically or releasing the plunger too quickly. Using damaged or incompatible tips can also cause leakage or inaccurate measurements. Environmental factors like temperature and humidity can affect liquid volume, especially with small volumes. Inconsistent pre-wetting or failure to calibrate regularly also contributes to errors.

3. What are the main parts of a Single Channel Variable Pipette?

The main parts include the plunger button, volume adjustment dial, tip ejector button, shaft, and disposable tip cone. The plunger controls aspiration and dispensing of liquid. The volume dial sets the desired liquid volume to be pipetted. The tip ejector allows safe and hands-free disposal of used tips. The shaft holds the pipette tip securely during operation.

4. How to calibrate a Single Channel Variable Pipette?

Calibration ensures the pipette dispenses the correct volume and is typically done using distilled water and a precision balance. The pipette is set to a target volume, and water is pipetted multiple times into a pre-weighed container. The weight is converted to volume considering water density at room temperature. If the dispensed volume differs from the set volume beyond acceptable tolerance, adjustments are made.

5. What is a Single Channel Variable Pipette and how does it work?

A Single Channel Variable Pipette is a laboratory instrument used to accurately measure and transfer small volumes of liquids. It has a single dispensing channel and allows users to adjust the volume within a specific range, such as 2–20 µL or 100–1000 µL. The volume is selected using a dial or rotating knob on the pipette. It works by creating a vacuum with a piston that aspirates and dispenses liquid through a disposable tip.

Similar Products of Single Channel Variable Pipette

Volume Range 2to 20 µl
Increment 0.5 µl
Test Volume 20 µl
10 µl
2 µl
Volume Range 2 to 20 µl
Increment 0.02 µl
Test Volume 2 µl
10 µl
20 µl
Volume Range 20 to 200 µl
Increment 1 µl
Test Volume 200µl
100µl
20 µl
Volume Range 0.2 to 2 µl
Increment 0.002 µl
Test Volume 0.2 µl
0.5µl
2 µl

Electronic Pipette

Electronic Pipette ADEP-506
Volume Range:500 to 10000 µl
Increment:10.00 µl
Test Volume:10000 µl <br/> 5000 µl <br/> 1000 µl
Electronic Pipette ADEP-503
Volume Range:10 to 300µl
Increment:0.20µl
Test Volume:30µl<br>150µl<br>300µl
Electronic Pipette ADEP-501
Volume Range:0.1 to 10 µl
Increment:0.01 µl
Test Volume:10 µl <br/> 5 µl <br/> 1 µl
Electronic Pipette ADEP-505
Volume Range:100to5000µl
Increment:5.00µl
Test Volume:5000µl<br/> 2500µl<br/> 500µl
Electronic Pipette ADEP-504
Volume Range:50-1000µl
Increment:1.00µl
Test Volume:100µl<br/> 500µl<br/> 1000µl
Electronic Pipette ADEP-502
Volume Range:5 to 120µl
Increment:0.10 µl
Test Volume:12 µl<br/> 60 µl<br/> 120 µl

Mini Fixed Volume Pipette

Mini Fixed Volume Pipette ADFVP-503
Volume Range:20µl
Accuracy:±1.0% at 20µl
Precision:±0.5% at 20µl
Mini Fixed Volume Pipette ADFVP-505
Volume Range:50µl
Accuracy:±1% at 50µl
Precision:±0.4% at 50µl
Mini Fixed Volume Pipette ADFVP-509
Volume Range:300µl
Accuracy:±0.8% at 300µl
Precision:±0.3% at 300µl
Mini Fixed Volume Pipette ADFVP-502
Volume Range:10µl
Accuracy:±1.2% at 10µl
Precision:±0.8% at 10µl
Mini Fixed Volume Pipette ADFVP-501
Volume Range:5µl
Accuracy:±2.5% at 5µl
Precision :±1.5% at 5µl
Mini Fixed Volume Pipette ADFVP-508
Volume Range:200µl
Accuracy:±0.8% at 200µl
Precision:±0.3% at 200µl
Mini Fixed Volume Pipette ADFVP-506
Volume Range:75µl
Accuracy:±0.8% at 75µl
Precision :±0.3% at 75µl
Mini Fixed Volume Pipette ADFVP-507
Volume Range:100µl
Accuracy:±0.8% at 100µl
Precision:±0.3% at 100µl
Mini Fixed Volume Pipette ADFVP-504
Volume Range:30µl
Accuracy:±1.0% at 30µl
Precision :±0.4% at 30µl

Multi-Channel Pipette

Multi-Channel Pipette ADMCP-501
Volume Range:0.5 to 10 µl
Increment:0.1 µl
Test Volume:10 µl<br/> 5 µl<br/> 1 µl
Multi-Channel Pipette ADMCP-506
Volume Range:30 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 30 µl
Multi-Channel Pipette ADMCP-512
Volume Range:20 to 200 µl
Increment:1 µl
Test Volume:200 µl<br/> 100 µl<br/> 10µl
Multi-Channel Pipette ADMCP-508
Volume Range:0.5 to 10 µl
Increment:0.1 µl
Test Volume:10 µl<br/> 5 µl<br/> 1 µl
Multi-Channel Pipette ADMCP-503
Volume Range:5 to 50 µl
Increment:0.5 µl
Test Volume:50 µl<br/> 25 µl<br/> 5 µl
Multi-Channel Pipette ADMCP-505
Volume Range:20 to 200 µl
Increment:1 µl
Test Volume:200 µl<br/> 100 µl<br/> 20 µl
Multi-Channel Pipette ADMCP-513
Volume Range:30 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 30µl
Multi-Channel Pipette ADMCP-509
Volume Range:2 to 20 µl
Increment:0.5 µl
Test Volume:20 µl<br/> 10 µl<br/> 2 µl
Multi-Channel Pipette ADMCP-507
Volume Range:50 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 50 µl
Multi-Channel Pipette ADMCP-510
Volume Range:5 to 50 µl
Increment:0.5 µl
Test Volume:50 µl<br/> 25 µl<br/> 5 µl
Multi-Channel Pipette ADMCP-504
Volume Range:10 to 100 µl
Increment:1 µl
Test Volume:100 µl<br/> 50 µl<br/> 10 µl
Multi-Channel Pipette ADMCP-511
Volume Range:10 to 100 µl
Increment:1 µl
Test Volume:100 µl<br/> 50 µl<br/> 2 µl
Multi-Channel Pipette ADMCP-502
Volume Range:2 to 20 µl
Increment:0.5 µl
Test Volume:20 µl<br/> 10 µl<br/> 2 µl
Multi-Channel Pipette ADMCP-514
Volume Range:50 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 50µl

Pipette With Switch

Pipette With Switch ADPWS-506
Volume Range:10 to 1000µl
Increment:5µl
Test Volume:1000µl <br/> 500µl <br/> 100µl
Pipette With Switch ADPWS-504
Volume Range:10 to 100µl
Increment:1µl
Test Volume:100µl <br/> 50µl <br/> 10µl
Pipette With Switch ADPWS-501
Volume Range:0.5 to 10µl
Increment:0.1µl
Test Volume:10µl <br/> 5µl <br/> 1µl
Pipette With Switch ADPWS-505
Volume Range:20 to 200µl
Increment:1µl
Test Volume:200µl <br/> 100µl <br/> 20µl
Pipette With Switch ADPWS-502
Volume Range:2 to 20µl
Increment:0.5µl
Test Volume:20µl <br/> 10µl <br/> 2µl
Pipette With Switch ADPWS-503
Volume Range:5 to 50µl
Increment:0.5µl
Test Volume:50µl <br/> 25µl <br/> 5µl
Pipette With Switch ADPWS-507
Volume Range:1 to 5µl
Increment:50µl
Test Volume:5000µl <br/> 2500µl <br/> 1000µl

Fixed Volume Pipette

Fixed Volume Pipette ADFPT-504
Volume:25µl
Accuracy:±3.00µl
Precision:≤1.50µl
Fixed Volume Pipette ADFPT-502
Volume:10µl
Accuracy:±4.80µl
Precision:≤2.50µl
Fixed Volume Pipette ADFPT-501
Volume:5µl
Accuracy:±8.00µl
Precision:≤5.00µl
Fixed Volume Pipette ADFPT-505
Volume:50µl
Accuracy:±3.00µl
Precision:≤1.50µl
Fixed Volume Pipette ADFPT-503
Volume:20µl
Accuracy:±3.00µl
Precision:≤1.50µl
Fixed Volume Pipette ADFPT-506
Volume:100µl
Accuracy:±2.00µl
Precision:≤1.00µl