Single Channel Variable Pipette ADCVP-507
Single Channel Variable Pipette ADCVP-507(Front View)
Single Channel Variable Pipette ADCVP-507(Front View)

Single Channel Variable Pipette ADCVP-507

Single Channel Variable Pipette ADCVP-507 comes with a volume range of 30 to 300 µl for handling very small liquid capacity with high precision. It is color-coded by volume for easy identification throughout the workflow. The tip ejector is conveniently responsive, allowing for easy tip disposal after each use. This unit comes with autoclavable components, allowing for sterilization and safe use in sensitive environments.  Our Single Channel Variable Pipette is used in diagnostics, pharmaceuticals, and research labs for liquid handling.


Volume Range 30to 300 µl
Increment 5 µl
Test Volume 300 µl
150 µl
30 µl
Accuracy ±0.70% at 300µl
±1.00% at 300 µl
±1.50% at 300 µl
Precision ±0.25% at 300 µl
±0.50% at 300 µl
±0.80%
Channel 1
Dimensions (L×B×H) 490×400×290 mm
  • Durable construction:
  • Low maintenance
  • Autoclavable components
  • Pre-calibrated
  • Fixed volume setting

Our Single Channel Variable Pipette ADCVP-507 is used in various fields, including clinical diagnostics, forensic science, and education, for accurate liquid handling and precise measurements. 

Frequently Asked Questions of Single Channel Variable Pipette ADCVP-507

1. What is a Single Channel Variable Pipette used for?

A single channel variable pipette is used to accurately measure and transfer small volumes of liquid in laboratories. It’s commonly used in biology, chemistry, and medical labs for experiments requiring precision. The “variable” feature allows the user to adjust the volume within a specific range. This makes it versatile for handling different sample volumes without switching instruments.

2. How do I set the desired volume on a Single Channel Variable Pipette?

To set the volume, rotate the volume adjustment knob or dial until the display shows your desired measurement. Single Channel Variable Pipette has a digital or mechanical volume indicator for precision. It’s important to never exceed the pipette maximum or minimum range to avoid damaging the instrument. After setting the volume, ensure the digits are aligned correctly and not between values.

3. How should I properly use a Single Channel Variable Pipette?

First, attach a compatible pipette tip firmly to avoid air leakage. Press the plunger to the first stop before immersing the tip into the liquid, then slowly release the plunger to aspirate. To dispense, press the plunger to the first stop to release liquid, and then fully press to the second stop to expel any remaining drops. Always hold the pipette vertically while aspirating for accuracy.

4. How to calibrate or maintain my Single Channel Variable Pipette?

Regular calibration, typically every 3-6 months, ensures the pipette remains accurate and reliable. Calibration involves comparing the dispensed volume with a known standard, often using a precision balance. Clean the pipette routinely, especially the lower parts and piston, using recommended solutions. Store the pipette upright on a stand when not in use to prevent contamination or damage.

5. What are common errors when using a Single Channel Variable Pipette and how to avoid them?

Common errors include incorrect pipetting technique, using wrong tips, setting volumes beyond the specified range, and inconsistent plunger speed. These mistakes can lead to inaccurate measurements and poor reproducibility. Always use proper pipette tips designed for your model to prevent leaks. Practice consistent plunger control and ensure proper pipette positioning during aspiration and dispensing.

Similar Products of Single Channel Variable Pipette

Volume Range 20 to 200 µl
Increment 0.2 µl
Test Volume 20 µl
100 µl
200 µl
Volume Range 1 to 5 µl
Increment 0.05 µl
Test Volume 5 µl
2.5µl
1 µl
Volume Range 2 to 20 µl
Increment 0.02 µl
Test Volume 2 µl
10 µl
20 µl
Volume Range 0.5 to 10 µl
Increment 0.02 µl
Test Volume 1 µl
5µl
10 µl

Electronic Pipette

Electronic Pipette ADEP-503
Volume Range:10 to 300µl
Increment:0.20µl
Test Volume:30µl<br>150µl<br>300µl
Electronic Pipette ADEP-504
Volume Range:50-1000µl
Increment:1.00µl
Test Volume:100µl<br/> 500µl<br/> 1000µl
Electronic Pipette ADEP-506
Volume Range:500 to 10000 µl
Increment:10.00 µl
Test Volume:10000 µl <br/> 5000 µl <br/> 1000 µl
Electronic Pipette ADEP-505
Volume Range:100to5000µl
Increment:5.00µl
Test Volume:5000µl<br/> 2500µl<br/> 500µl
Electronic Pipette ADEP-501
Volume Range:0.1 to 10 µl
Increment:0.01 µl
Test Volume:10 µl <br/> 5 µl <br/> 1 µl
Electronic Pipette ADEP-502
Volume Range:5 to 120µl
Increment:0.10 µl
Test Volume:12 µl<br/> 60 µl<br/> 120 µl

Mini Fixed Volume Pipette

Mini Fixed Volume Pipette ADFVP-508
Volume Range:200µl
Accuracy:±0.8% at 200µl
Precision:±0.3% at 200µl
Mini Fixed Volume Pipette ADFVP-504
Volume Range:30µl
Accuracy:±1.0% at 30µl
Precision :±0.4% at 30µl
Mini Fixed Volume Pipette ADFVP-502
Volume Range:10µl
Accuracy:±1.2% at 10µl
Precision:±0.8% at 10µl
Mini Fixed Volume Pipette ADFVP-503
Volume Range:20µl
Accuracy:±1.0% at 20µl
Precision:±0.5% at 20µl
Mini Fixed Volume Pipette ADFVP-509
Volume Range:300µl
Accuracy:±0.8% at 300µl
Precision:±0.3% at 300µl
Mini Fixed Volume Pipette ADFVP-505
Volume Range:50µl
Accuracy:±1% at 50µl
Precision:±0.4% at 50µl
Mini Fixed Volume Pipette ADFVP-501
Volume Range:5µl
Accuracy:±2.5% at 5µl
Precision :±1.5% at 5µl
Mini Fixed Volume Pipette ADFVP-506
Volume Range:75µl
Accuracy:±0.8% at 75µl
Precision :±0.3% at 75µl
Mini Fixed Volume Pipette ADFVP-507
Volume Range:100µl
Accuracy:±0.8% at 100µl
Precision:±0.3% at 100µl

Multi-Channel Pipette

Multi-Channel Pipette ADMCP-502
Volume Range:2 to 20 µl
Increment:0.5 µl
Test Volume:20 µl<br/> 10 µl<br/> 2 µl
Multi-Channel Pipette ADMCP-501
Volume Range:0.5 to 10 µl
Increment:0.1 µl
Test Volume:10 µl<br/> 5 µl<br/> 1 µl
Multi-Channel Pipette ADMCP-508
Volume Range:0.5 to 10 µl
Increment:0.1 µl
Test Volume:10 µl<br/> 5 µl<br/> 1 µl
Multi-Channel Pipette ADMCP-513
Volume Range:30 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 30µl
Multi-Channel Pipette ADMCP-510
Volume Range:5 to 50 µl
Increment:0.5 µl
Test Volume:50 µl<br/> 25 µl<br/> 5 µl
Multi-Channel Pipette ADMCP-511
Volume Range:10 to 100 µl
Increment:1 µl
Test Volume:100 µl<br/> 50 µl<br/> 2 µl
Multi-Channel Pipette ADMCP-506
Volume Range:30 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 30 µl
Multi-Channel Pipette ADMCP-507
Volume Range:50 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 50 µl
Multi-Channel Pipette ADMCP-512
Volume Range:20 to 200 µl
Increment:1 µl
Test Volume:200 µl<br/> 100 µl<br/> 10µl
Multi-Channel Pipette ADMCP-504
Volume Range:10 to 100 µl
Increment:1 µl
Test Volume:100 µl<br/> 50 µl<br/> 10 µl
Multi-Channel Pipette ADMCP-505
Volume Range:20 to 200 µl
Increment:1 µl
Test Volume:200 µl<br/> 100 µl<br/> 20 µl
Multi-Channel Pipette ADMCP-514
Volume Range:50 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 50µl
Multi-Channel Pipette ADMCP-509
Volume Range:2 to 20 µl
Increment:0.5 µl
Test Volume:20 µl<br/> 10 µl<br/> 2 µl
Multi-Channel Pipette ADMCP-503
Volume Range:5 to 50 µl
Increment:0.5 µl
Test Volume:50 µl<br/> 25 µl<br/> 5 µl

Pipette With Switch

Pipette With Switch ADPWS-505
Volume Range:20 to 200µl
Increment:1µl
Test Volume:200µl <br/> 100µl <br/> 20µl
Pipette With Switch ADPWS-501
Volume Range:0.5 to 10µl
Increment:0.1µl
Test Volume:10µl <br/> 5µl <br/> 1µl
Pipette With Switch ADPWS-507
Volume Range:1 to 5µl
Increment:50µl
Test Volume:5000µl <br/> 2500µl <br/> 1000µl
Pipette With Switch ADPWS-502
Volume Range:2 to 20µl
Increment:0.5µl
Test Volume:20µl <br/> 10µl <br/> 2µl
Pipette With Switch ADPWS-504
Volume Range:10 to 100µl
Increment:1µl
Test Volume:100µl <br/> 50µl <br/> 10µl
Pipette With Switch ADPWS-506
Volume Range:10 to 1000µl
Increment:5µl
Test Volume:1000µl <br/> 500µl <br/> 100µl
Pipette With Switch ADPWS-503
Volume Range:5 to 50µl
Increment:0.5µl
Test Volume:50µl <br/> 25µl <br/> 5µl

Fixed Volume Pipette

Fixed Volume Pipette ADFPT-501
Volume:5µl
Accuracy:±8.00µl
Precision:≤5.00µl
Fixed Volume Pipette ADFPT-503
Volume:20µl
Accuracy:±3.00µl
Precision:≤1.50µl
Fixed Volume Pipette ADFPT-502
Volume:10µl
Accuracy:±4.80µl
Precision:≤2.50µl
Fixed Volume Pipette ADFPT-505
Volume:50µl
Accuracy:±3.00µl
Precision:≤1.50µl
Fixed Volume Pipette ADFPT-504
Volume:25µl
Accuracy:±3.00µl
Precision:≤1.50µl
Fixed Volume Pipette ADFPT-506
Volume:100µl
Accuracy:±2.00µl
Precision:≤1.00µl