Single Channel Variable Pipette ADCVP-518

Single Channel Variable Pipette ADCVP-518

Single Channel Variable Pipette ADCVP-518 comes with a volume range of 1 to 10 µl for handling very small liquid capacity with high precision. This unit has a clear volume display, enabling easy and precise volume setting. The smooth piston mechanism ensures consistent aspiration and dispensing of liquids. It features a tip ejector for safe and contamination-free disposal of pipette tips. Our Single Channel Variable Pipette is used in diagnostics, pharmaceuticals, and research labs for liquid handling.


Volume Range 1 to 10 µl
Increment 20 µl
Test Volume 1 µl
5µl
10 µl
Accuracy ±3.00 % at 10 µl
±0.60 % at 5 µl
±0.60 % at 1 µl
Precision ≤0.60 % at 10 µl
0.20 % at 5 µl
≤0.16 % at 1 µl
Channel 1
Gross Weight 19.9 kg
Dimensions (L×B×H) 505×410×317 mm
  • Single channel design
  • Adjustable volume control
  • Calibration adjustment
  • Ejector mechanism
  • Autoclavable components

Our Single Channel Variable Pipette ADCVP-518 is used in biotechnology diagnostics, and research for precise liquid handling in sample preparation, reagent dispensing, and DNA/RNA work.

Single Channel Variable Pipette ADCVP-518|ncrement:20 µl|Test Volume: 1 µl 5 µl 10 µl
Single Channel Variable Pipette ADCVP-518|Single channel design|Adjustable volume control

Frequently Asked Questions of Single Channel Variable Pipette ADCVP-518

1. What are the steps to use a Single Channel Variable Pipette correctly?

Begin by setting the desired volume on the pipette’s dial. Attach a proper-size disposable tip securely to the nozzle. Press the plunger to the first stop before immersing the tip in the liquid, then slowly release it to aspirate. To dispense, press the plunger to the first stop, and then to the second stop to expel any remaining liquid. Eject the tip into a waste container to avoid contamination.

2. How to calibrate a Single Channel Variable Pipette?

Calibration involves verifying and adjusting the pipette's accuracy by comparing its output volume to a known standard. First, distilled water is weighed using an analytical balance to measure the volume dispensed. Temperature and density corrections are applied to convert mass to volume. If the deviation is outside acceptable limits, internal adjustments are made.

3. What is a Single Channel Variable Pipette and how does it work?

A Single Channel Variable Pipette is a laboratory instrument used to aspirate and dispense liquid volumes with precision. It has a single nozzle and can be adjusted to deliver varying volumes, typically in microliters. The user sets the desired volume using a rotating dial or digital interface. When the plunger is pressed and released, the pipette draws the liquid into a disposable tip, and then dispenses it.

4. What are common errors to avoid when using a Single Channel Variable Pipette?

Avoid pipetting at an angle, as this can lead to inaccurate volumes. Do not let the plunger snap back, as it may damage the internal mechanism and affect aspiration. Always use the correct tip and ensure it’s firmly attached to prevent leakage. Refrain from exceeding the pipette’s volume range, as this compromises accuracy. Clean and calibrate the pipette regularly to maintain optimal performance.

5. What is the difference between Fixed Volume and Single Channel Variable Pipette?

Fixed Volume Pipette is designed to dispense only one set volume, which cannot be changed, making them ideal for repetitive tasks that require high consistency. Single Channel Variable pipette, on the other hand, allow users to adjust the volume within a specific range, offering more flexibility for different experimental needs. Single Channel Variable Pipette is more versatile but require careful setting and calibration.

Similar Products of Single Channel Variable Pipette

Volume Range 0.5 to 10 µl
Increment 0.1 µl
Test Volume 1 µl
5µl
1 µl
Volume Range 10 to 100 µl
Increment 0.2 µl
Test Volume 10 µl
50 µl
100 µl
Volume Range 5 to 50 µl
Increment 0.5 µl
Test Volume 50 µl
25 µl
5 µl
Volume Range 20 to 200 µl
Increment 0.2 µl
Test Volume 20 µl
100 µl
200 µl

Electronic Pipette

Electronic Pipette ADEP-506
Volume Range:500 to 10000 µl
Increment:10.00 µl
Test Volume:10000 µl <br/> 5000 µl <br/> 1000 µl
Electronic Pipette ADEP-504
Volume Range:50-1000µl
Increment:1.00µl
Test Volume:100µl<br/> 500µl<br/> 1000µl
Electronic Pipette ADEP-503
Volume Range:10 to 300µl
Increment:0.20µl
Test Volume:30µl<br>150µl<br>300µl
Electronic Pipette ADEP-502
Volume Range:5 to 120µl
Increment:0.10 µl
Test Volume:12 µl<br/> 60 µl<br/> 120 µl
Electronic Pipette ADEP-505
Volume Range:100to5000µl
Increment:5.00µl
Test Volume:5000µl<br/> 2500µl<br/> 500µl
Electronic Pipette ADEP-501
Volume Range:0.1 to 10 µl
Increment:0.01 µl
Test Volume:10 µl <br/> 5 µl <br/> 1 µl

Mini Fixed Volume Pipette

Mini Fixed Volume Pipette ADFVP-502
Volume Range:10µl
Accuracy:±1.2% at 10µl
Precision:±0.8% at 10µl
Mini Fixed Volume Pipette ADFVP-504
Volume Range:30µl
Accuracy:±1.0% at 30µl
Precision :±0.4% at 30µl
Mini Fixed Volume Pipette ADFVP-508
Volume Range:200µl
Accuracy:±0.8% at 200µl
Precision:±0.3% at 200µl
Mini Fixed Volume Pipette ADFVP-509
Volume Range:300µl
Accuracy:±0.8% at 300µl
Precision:±0.3% at 300µl
Mini Fixed Volume Pipette ADFVP-505
Volume Range:50µl
Accuracy:±1% at 50µl
Precision:±0.4% at 50µl
Mini Fixed Volume Pipette ADFVP-503
Volume Range:20µl
Accuracy:±1.0% at 20µl
Precision:±0.5% at 20µl
Mini Fixed Volume Pipette ADFVP-506
Volume Range:75µl
Accuracy:±0.8% at 75µl
Precision :±0.3% at 75µl
Mini Fixed Volume Pipette ADFVP-507
Volume Range:100µl
Accuracy:±0.8% at 100µl
Precision:±0.3% at 100µl
Mini Fixed Volume Pipette ADFVP-501
Volume Range:5µl
Accuracy:±2.5% at 5µl
Precision :±1.5% at 5µl

Multi-Channel Pipette

Multi-Channel Pipette ADMCP-510
Volume Range:5 to 50 µl
Increment:0.5 µl
Test Volume:50 µl<br/> 25 µl<br/> 5 µl
Multi-Channel Pipette ADMCP-513
Volume Range:30 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 30µl
Multi-Channel Pipette ADMCP-502
Volume Range:2 to 20 µl
Increment:0.5 µl
Test Volume:20 µl<br/> 10 µl<br/> 2 µl
Multi-Channel Pipette ADMCP-501
Volume Range:0.5 to 10 µl
Increment:0.1 µl
Test Volume:10 µl<br/> 5 µl<br/> 1 µl
Multi-Channel Pipette ADMCP-508
Volume Range:0.5 to 10 µl
Increment:0.1 µl
Test Volume:10 µl<br/> 5 µl<br/> 1 µl
Multi-Channel Pipette ADMCP-506
Volume Range:30 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 30 µl
Multi-Channel Pipette ADMCP-503
Volume Range:5 to 50 µl
Increment:0.5 µl
Test Volume:50 µl<br/> 25 µl<br/> 5 µl
Multi-Channel Pipette ADMCP-507
Volume Range:50 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 50 µl
Multi-Channel Pipette ADMCP-509
Volume Range:2 to 20 µl
Increment:0.5 µl
Test Volume:20 µl<br/> 10 µl<br/> 2 µl
Multi-Channel Pipette ADMCP-505
Volume Range:20 to 200 µl
Increment:1 µl
Test Volume:200 µl<br/> 100 µl<br/> 20 µl
Multi-Channel Pipette ADMCP-512
Volume Range:20 to 200 µl
Increment:1 µl
Test Volume:200 µl<br/> 100 µl<br/> 10µl
Multi-Channel Pipette ADMCP-514
Volume Range:50 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 50µl
Multi-Channel Pipette ADMCP-511
Volume Range:10 to 100 µl
Increment:1 µl
Test Volume:100 µl<br/> 50 µl<br/> 2 µl
Multi-Channel Pipette ADMCP-504
Volume Range:10 to 100 µl
Increment:1 µl
Test Volume:100 µl<br/> 50 µl<br/> 10 µl

Pipette With Switch

Pipette With Switch ADPWS-502
Volume Range:2 to 20µl
Increment:0.5µl
Test Volume:20µl <br/> 10µl <br/> 2µl
Pipette With Switch ADPWS-503
Volume Range:5 to 50µl
Increment:0.5µl
Test Volume:50µl <br/> 25µl <br/> 5µl
Pipette With Switch ADPWS-506
Volume Range:10 to 1000µl
Increment:5µl
Test Volume:1000µl <br/> 500µl <br/> 100µl
Pipette With Switch ADPWS-505
Volume Range:20 to 200µl
Increment:1µl
Test Volume:200µl <br/> 100µl <br/> 20µl
Pipette With Switch ADPWS-504
Volume Range:10 to 100µl
Increment:1µl
Test Volume:100µl <br/> 50µl <br/> 10µl
Pipette With Switch ADPWS-501
Volume Range:0.5 to 10µl
Increment:0.1µl
Test Volume:10µl <br/> 5µl <br/> 1µl
Pipette With Switch ADPWS-507
Volume Range:1 to 5µl
Increment:50µl
Test Volume:5000µl <br/> 2500µl <br/> 1000µl

Fixed Volume Pipette

Fixed Volume Pipette ADFPT-502
Volume:10µl
Accuracy:±4.80µl
Precision:≤2.50µl
Fixed Volume Pipette ADFPT-501
Volume:5µl
Accuracy:±8.00µl
Precision:≤5.00µl
Fixed Volume Pipette ADFPT-505
Volume:50µl
Accuracy:±3.00µl
Precision:≤1.50µl
Fixed Volume Pipette ADFPT-504
Volume:25µl
Accuracy:±3.00µl
Precision:≤1.50µl
Fixed Volume Pipette ADFPT-506
Volume:100µl
Accuracy:±2.00µl
Precision:≤1.00µl
Fixed Volume Pipette ADFPT-503
Volume:20µl
Accuracy:±3.00µl
Precision:≤1.50µl