| Volume Range | 1 to 5 µl |
| Increment | 0.05 µl |
| Test Volume |
5 µl 2.5µl 1 µl |
| Accuracy |
±0.50% at 5 µl ±0.60% at 5 µl ±0.70% at 5 µl |
| Precision |
±0.15% at 5 µl ±0.30% at 5 µl ±0.30% at 5 µl |
| Channel | 1 |
| Dimensions (L×B×H) | 490×400×290 mm |
Our Single Channel Variable Pipette ADCVP-509 is used for tasks such as enzyme assays, cell culture media transfer and protein quantification, making it essential in microbiology, biotechnology and forensic science labs.
1. What is a Single Channel Variable Pipette used for?
A Single Channel Variable Pipette is used to accurately measure and transfer small volumes of liquid in laboratories. It’s designed for tasks like preparing samples, mixing reagents, or dispensing precise liquid amounts. The "single channel" means it transfers liquid through one tip at a time. The "variable" feature allows users to adjust the volume setting within a specific range.
2. How do I properly calibrate a Single Channel Variable Pipette?
Calibration involves comparing the pipette's dispensed volume against a known standard, typically using a balance. First, set the desired volume and dispense distilled water into a pre-weighed container. Repeat the process multiple times to calculate the average dispensed volume. If discrepancies are found, adjust the pipette following the manufacturer’s instructions or have it professionally calibrated.
3. How should I maintain and clean my Single Channel Variable Pipette?
Regular cleaning involves wiping the exterior with 70% ethanol and occasionally sterilizing the lower parts. Disassemble the pipette as per the manual to clean internal parts if there’s contamination. Always use proper filter tips to minimize internal damage from liquids. Avoid immersing the pipette beyond the recommended level to protect internal components. Routine maintenance ensures accuracy and prolongs the pipette’s lifespan.
4. How often should I calibrate and service my Single Channel Variable Pipette?
It is generally recommended to calibrate pipettes every 3-6 months depending on usage intensity. High-precision applications may require monthly calibration checks. Regular servicing, including cleaning and lubrication, should also follow a biannual or annual schedule. Keeping a log of calibration and maintenance helps track pipette performance. Frequent checks ensure reliable results and compliance with lab standards.
5. What is the correct way to use a Single Channel Variable Pipette?
Start by setting the desired volume using the adjustment knob. Attach a clean, compatible pipette tip firmly without excessive force. Press the plunger to the first stop before immersing the tip into the liquid. Slowly release the plunger to aspirate, then dispense by pressing to the second stop for complete delivery. Always handle gently and keep the pipette vertical during aspiration for accurate results.
| Volume Range | 5 to 50 µl |
| Increment | 0.5 µl |
| Test Volume |
50 µl 25 µl 5 µl |
| Volume Range | 0.5 to 5 µl |
| Increment | 20 µl |
| Test Volume |
1000 µl 2500 µl 5000 µl |
| Volume Range | 30to 300 µl |
| Increment | 5 µl |
| Test Volume |
300 µl 150 µl 30 µl |
| Volume Range | 20 to 200 µl |
| Increment | 0.2 µl |
| Test Volume |
20 µl 100 µl 200 µl |
| Volume Range: | 0.1 to 10 µl |
| Increment: | 0.01 µl |
| Test Volume: | 10 µl <br/> 5 µl <br/> 1 µl |
| Volume Range: | 10 to 300µl |
| Increment: | 0.20µl |
| Test Volume: | 30µl<br>150µl<br>300µl |
| Volume Range: | 5 to 120µl |
| Increment: | 0.10 µl |
| Test Volume: | 12 µl<br/> 60 µl<br/> 120 µl |
| Volume Range: | 50-1000µl |
| Increment: | 1.00µl |
| Test Volume: | 100µl<br/> 500µl<br/> 1000µl |
| Volume Range: | 500 to 10000 µl |
| Increment: | 10.00 µl |
| Test Volume: | 10000 µl <br/> 5000 µl <br/> 1000 µl |
| Volume Range: | 100to5000µl |
| Increment: | 5.00µl |
| Test Volume: | 5000µl<br/> 2500µl<br/> 500µl |
| Volume Range: | 50µl |
| Accuracy: | ±1% at 50µl |
| Precision: | ±0.4% at 50µl |
| Volume Range: | 10µl |
| Accuracy: | ±1.2% at 10µl |
| Precision: | ±0.8% at 10µl |
| Volume Range: | 75µl |
| Accuracy: | ±0.8% at 75µl |
| Precision : | ±0.3% at 75µl |
| Volume Range: | 200µl |
| Accuracy: | ±0.8% at 200µl |
| Precision: | ±0.3% at 200µl |
| Volume Range: | 20µl |
| Accuracy: | ±1.0% at 20µl |
| Precision: | ±0.5% at 20µl |
| Volume Range: | 5µl |
| Accuracy: | ±2.5% at 5µl |
| Precision : | ±1.5% at 5µl |
| Volume Range: | 300µl |
| Accuracy: | ±0.8% at 300µl |
| Precision: | ±0.3% at 300µl |
| Volume Range: | 100µl |
| Accuracy: | ±0.8% at 100µl |
| Precision: | ±0.3% at 100µl |
| Volume Range: | 30µl |
| Accuracy: | ±1.0% at 30µl |
| Precision : | ±0.4% at 30µl |
| Volume Range: | 30 to 300 µl |
| Increment: | 5 µl |
| Test Volume: | 300 µl<br/> 150 µl<br/> 30µl |
| Volume Range: | 10 to 100 µl |
| Increment: | 1 µl |
| Test Volume: | 100 µl<br/> 50 µl<br/> 10 µl |
| Volume Range: | 2 to 20 µl |
| Increment: | 0.5 µl |
| Test Volume: | 20 µl<br/> 10 µl<br/> 2 µl |
| Volume Range: | 50 to 300 µl |
| Increment: | 5 µl |
| Test Volume: | 300 µl<br/> 150 µl<br/> 50µl |
| Volume Range: | 0.5 to 10 µl |
| Increment: | 0.1 µl |
| Test Volume: | 10 µl<br/> 5 µl<br/> 1 µl |
| Volume Range: | 2 to 20 µl |
| Increment: | 0.5 µl |
| Test Volume: | 20 µl<br/> 10 µl<br/> 2 µl |
| Volume Range: | 5 to 50 µl |
| Increment: | 0.5 µl |
| Test Volume: | 50 µl<br/> 25 µl<br/> 5 µl |
| Volume Range: | 20 to 200 µl |
| Increment: | 1 µl |
| Test Volume: | 200 µl<br/> 100 µl<br/> 10µl |
| Volume Range: | 5 to 50 µl |
| Increment: | 0.5 µl |
| Test Volume: | 50 µl<br/> 25 µl<br/> 5 µl |
| Volume Range: | 10 to 100 µl |
| Increment: | 1 µl |
| Test Volume: | 100 µl<br/> 50 µl<br/> 2 µl |
| Volume Range: | 0.5 to 10 µl |
| Increment: | 0.1 µl |
| Test Volume: | 10 µl<br/> 5 µl<br/> 1 µl |
| Volume Range: | 20 to 200 µl |
| Increment: | 1 µl |
| Test Volume: | 200 µl<br/> 100 µl<br/> 20 µl |
| Volume Range: | 30 to 300 µl |
| Increment: | 5 µl |
| Test Volume: | 300 µl<br/> 150 µl<br/> 30 µl |
| Volume Range: | 50 to 300 µl |
| Increment: | 5 µl |
| Test Volume: | 300 µl<br/> 150 µl<br/> 50 µl |
| Volume Range: | 5 to 50µl |
| Increment: | 0.5µl |
| Test Volume: | 50µl <br/> 25µl <br/> 5µl |
| Volume Range: | 1 to 5µl |
| Increment: | 50µl |
| Test Volume: | 5000µl <br/> 2500µl <br/> 1000µl |
| Volume Range: | 0.5 to 10µl |
| Increment: | 0.1µl |
| Test Volume: | 10µl <br/> 5µl <br/> 1µl |
| Volume Range: | 10 to 1000µl |
| Increment: | 5µl |
| Test Volume: | 1000µl <br/> 500µl <br/> 100µl |
| Volume Range: | 20 to 200µl |
| Increment: | 1µl |
| Test Volume: | 200µl <br/> 100µl <br/> 20µl |
| Volume Range: | 10 to 100µl |
| Increment: | 1µl |
| Test Volume: | 100µl <br/> 50µl <br/> 10µl |
| Volume Range: | 2 to 20µl |
| Increment: | 0.5µl |
| Test Volume: | 20µl <br/> 10µl <br/> 2µl |