Hot Air Sterilizer ADSH-502

Hot Air Sterilizer ADSH-502

Advalab Hot Air Sterilizer ADSH-502 offers ample capacity of 142 L for efficient storage of a wide variety of items. LCD screen allows for easy control and monitoring of both heat and time. Our unit offers a programmable design with 10 segments and 100 cycles for customized settings. With a wide 5°C to 85°C temperature range, it maintains optimal conditions for sensitive samples. This Hot Air Sterilizer is used in research and laboratories, food industries, and field hospitals to sterilize tools and equipment.


Volume 129 L
Temperature Range 5 to 300°C
Temperature Resolution 0.1°C
Temperature Fluctuation 0.3°C
Temperature Uniformity 1.9°C
Heating Up Time 20 min
Timer Range 0 to 9999 min
Reservation Range 0 to 9999 min
Number of Shelves 2/7 pc
Load per Shelf 25 kg
Power Consumption 2150 W
Power Supply 220±10 V, 50/60 Hz
Internal Dimensions [W×D×H] 570×400×570 mm
Housing Dimensions [W×D×H] 715×616×842 mm
Package Dimensions [W×D×H] 835×776×992 mm
Net Weight 57 kg
Gross Weight 75 kg
  • Adjustable fan speed
  • Dual overheat protection
  • Air filtration system
  • Countdown timer
  • Delayed start function

Our Hot Air Sterilizer ADSH-502 is used in research laboratories, and pharmaceutical industries for sterilizing instruments, media, ensuring safe conditions.

  1. Universal external printer × 1 pc

Frequently Asked Questions of Hot Air Sterilizer ADSH-502

1. Can a Hot Air Sterilizer sterilize sealed containers?

A Hot Air Sterilizer can sterilize sealed containers only if they are heat-resistant and allow heat penetration. The Hot Air Sterilizer may not effectively sterilize airtight containers unless vents are present.

2. What precautions should be taken while using a Hot Air Sterilizer?

When using a Hot Air Sterilizer, always preheat the unit, wear heat-resistant gloves, and avoid opening the door mid-cycle. The Hot Air Sterilizer reaches very high temperatures that can cause burns.

3. What is a Hot Air Sterilizer and how does it work?

A Hot Air Sterilizer is a dry heat sterilization device used to sterilize items by circulating hot air. The Hot Air Sterilizer works by raising temperatures to 160°C–180°C for a set time. It kills microorganisms through oxidation without using moisture. It is ideal for glassware, metal, and powders.

4. What materials can be sterilized in a Hot Air Sterilizer?

A Hot Air Sterilizer can sterilize metal instruments, glassware, powders, and oils that withstand dry heat. Materials placed in the Hot Air Sterilizer must be moisture-sensitive and heat-stable.

5. Is a Hot Air Sterilizer safe for sterilizing wrapped instruments?

Yes, a Hot Air Sterilizer can sterilize wrapped instruments if the wrapping is heat-resistant. The Hot Air Sterilizer maintains sterility during storage if the wrapping remains intact. Only use wraps approved for dry heat. Improper wrapping may lead to contamination or melting.

Similar Products of Hot Air Sterilizer

Volume 452 L
Temperature Range 5 to 300°C
Temperature Resolution 0.1°C
Volume 284 L
Temperature Range 5 to 300°C
Temperature Resolution 0.1°C
Volume 210 L
Temperature Range 5 to 300°C
Temperature Resolution 0.1°C
Volume 64 L
Temperature Range 5 to 300°C
Temperature Resolution 0.1°C

Electric Heated Sterilizer

Electric Heated Sterilizer ADEH-502
Capacity:50 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-506
Capacity:150 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-503
Capacity:75 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-501
Capacity:35 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-505
Capacity:120 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-504
Capacity:100 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa

Horizontal Pressure Sterilizer

Horizontal Pressure Sterilizer ADHP-502
Capacity:200 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 60 min
Horizontal Pressure Sterilizer ADHP-501
Capacity:150 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 60 min
Horizontal Pressure Sterilizer ADHP-503
Capacity:280 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 60 min

Horizontal Sterilizer

Horizontal Sterilizer ADHR-502
Capacity:200 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 99 min
Horizontal Sterilizer ADHR-503
Capacity:280 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 99 min
Horizontal Sterilizer ADHR-501
Capacity:150 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 99 min

Glass Bead Sterilizer

Glass Bead Sterilizer ADGBS-503
Temperature Range:100℃ to 300℃
Temperature Accuracy:± 5℃
Display Accuracy:1℃
Glass Bead Sterilizer ADGBS-504
Temperature Range:100℃ to 300℃
Temperature Accuracy:± 5℃
Display Accuracy:1℃
Glass Bead Sterilizer ADGBS-502
Temperature Range:100 to 300℃
Temperature Accuracy:≤ 5℃
Heating Rate:≤ 25 min, Room temperature to 300℃
Glass Bead Sterilizer ADGBS-501
Temperature Range:100 to 300℃
Temperature Accuracy:≤ 5℃
Heating Rate:≤ 25 min ,Room temperature to 300℃

Bacti-Cinerator Sterilizer

Bacti-Cinerator Sterilizer ADBCS-503
Central Temperature:825°C ± 25°C
Maximum Outside Diameter of Sterilized Items:ɸ15mm
Heating Zone Length:140 mm
Bacti-Cinerator Sterilizer ADBCS-501
Central High Temperature:800℃ ± 50℃
Standby Temperature:400℃ ± 50℃
Heater Head Angle:21°
Bacti-Cinerator Sterilizer ADBCS-504
Central Temperature:825°C ± 25°C
Maximum Outside Diameter of Sterilized Items:ɸ35mm
Heating Zone Length:100 mm
Bacti-Cinerator Sterilizer ADBCS-502
Central High Temperature:800℃ ± 50℃
Standby Temperature:400℃ ± 50℃
Heater Head Angle:21°