| Main Chamber Dimension (L×B×H) | 800 × 550 × 600mm |
| Material Thickness | 6mm |
| H₂O and O₂ Content | 200 to 300 PPM |
| Side Door Dimension (L×B) | 300 × 300mm |
| Power Supply | 220V, 50Hz / 60Hz |
| Packing Dimension (L×B×H) | 1180 × 670 × 820 mm |
| Net Weight | 22kg |
Acrylic Glove Box ADAGB-503 allow safe manipulation of reactive substances without direct contact. It is commonly used in analytical labs, educational institutions, and production units.
1. What is the main chamber size of Acrylic Glove Box ADAGB-503?
The main chamber measures 800 × 550 × 600?mm, offering ample space for various laboratory tasks, experiments, and equipment handling while maintaining a high-purity, controlled atmosphere for sensitive operations.
2. How can gases be introduced into Acrylic Glove Box ADAGB-503?
Gases are introduced through a stainless-steel ball valve, which enables precise and controlled entry, ensuring the internal atmosphere remains stable and suitable for sensitive experiments while maintaining safety and preventing contamination.
3. What is the H?O and O? content inside Acrylic Glove Box ADAGB-503?
The Acrylic Glove Box ADAGB-503 maintains an ultra-low H?O and O? environment, ranging from 200 to 300?PPM. This ensures a highly controlled, high-purity atmosphere, ideal for handling sensitive materials and conducting experiments without contamination.
4. What are the side door dimensions of Acrylic Glove Box ADAGB-503?
The side door of Acrylic Glove Box ADAGB-503 measures 300 × 300?mm, allowing convenient placement and removal of equipment, materials, or samples without disturbing the controlled internal environment.
5. Are the gloves on Acrylic Glove Box ADAGB-503 chemical-resistant?
Yes, Acrylic Glove Box ADAGB-503 comes with durable, chemical-resistant latex gloves featuring reinforced sealing rings, ensuring secure, precise handling of materials while maintaining a contamination-free atmosphere.
6. Why choose acrylic material for a glove box?
Acrylic is an ideal choice because it is lightweight yet highly durable, offering long-lasting performance. Its excellent transparency ensures clear visibility during experiments, while the smooth, non-porous surface provides strong chemical resistance and makes cleaning simple and efficient.
7. Can an Acrylic Glove Box maintain a controlled atmosphere?
Yes, Acrylic Glove Boxes can be equipped with gas inlet/outlet ports and purging systems that allow operation under inert gas or low-humidity conditions. This ensures safe handling of moisture-sensitive, air-sensitive, or hazardous materials in research and industrial processes.
8. Is the Acrylic Glove Box easy to clean and maintain?
Yes, the non-porous acrylic surface makes the glove box simple to clean and maintain. Regular wiping with suitable cleaning agents keeps it clear and contamination-free, ensuring durability and hygiene for long-term laboratory or industrial use without compromising performance.
| Main Chamber Dimension (L×B×H) | 700 × 450 × 550 mm |
| Material Thickness | 6 mm |
| H₂O and O₂ Content | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H) | 800 × 550 × 600 mm |
| Antechamber Dimension (L×B×H) | 260 × 260 × 260mm |
| H₂O and O₂ Content | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H) | 300 × 400 × 500mm |
| Material Thickness | 6 mm |
| H₂O and O₂ Content | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H) | 900 × 600 × 700 mm |
| Antechamber Dimension(L×B×H) | 260 × 260 × 260mm |
| H₂O and O₂ Content | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H): | 800 × 650 × 680mm |
| Thickness : | 3mm |
| Vacuum Degree: | -0.1mpa |
| Main Chamber Dimension (L×B×H): | 1120 × 750 × 900mm |
| Thickness : | 3mm |
| Vacuum Degree: | -0.1mpa |
| Main Chamber Dimension (L×B×H): | 800 × 650 × 680mm |
| Thickness : | 3mm |
| Vacuum Degree: | -0.1mpa |
| Main Chamber Dimension (L×B×H): | 1120 × 750 × 900mm |
| Thickness : | 3mm |
| Vacuum Degree: | -0.1mpa |
| Material: | Stainless steel |
| Air Lock Size: | 200 mm dia. x 260 mm length |
| Main Chamber Size: | 550 mm (W) x 440 mm (D) x 410 mm (H) |
| Main Chamber Dimension (L×B×H): | 600 × 450 × 450mm |
| Thickness : | 3mm |
| Vacuum Degree: | -0.1mpa |
| Main Chamber Dimension (L×B×H): | 600 × 450 × 450mm |
| Thickness : | 3mm |
| Vacuum Degree: | -0.1mpa |
| Working Gas: | Nitrogen, argon (gas purity 99.999%) |
| H₂O and O₂ Index: | Less than 1PPM |
| Circulating Capacity: | Integrated fan flow rate of 90m³/h |
| Working Gas: | Nitrogen, argon (gas purity 99.999%) |
| H₂O and O₂ Index: | Less than 1PPM |
| Circulating Capacity: | Integrated fan flow rate of 90m³/h |
| Working Gas: | Nitrogen, argon (gas purity 99.999%) |
| H₂O and O₂ Index: | Less than 1PPM |
| Material: | Stainless steel, 3mm thickness |
| Working Gas: | Nitrogen, argon (gas purity 99.999%) |
| H₂O and O₂ Index: | Less than 1PPM |
| Circulating Capacity: | Integrated fan flow rate of 90m³/h |
| Working Gas: | Nitrogen, argon (gas purity 99.999%) |
| H₂O and O₂ Index: | Less than 1PPM |
| Circulating Capacity: | Integrated fan flow rate of 90m³/h |