| Working Gas | Nitrogen, argon (gas purity 99.999%) |
| H₂O and O₂ Index | Less than 1PPM |
| Circulating Capacity | Integrated fan flow rate of 90m³/h |
| Material | Stainless steel, 3mm thickness |
| Main Chamber Dimension (L×B×H) | 1900 × 760 × 900mm |
| Antechamber Dimension (D×L) | Large:377×600 mm, Small:150×300 mm |
| Sight Window | Inclined, tempered glass, 8mm thickness |
| Number Of Glove Port | 4 |
| Glove Port Material | Anodized aluminum oxide, O-ring sealed |
| Gloves | Butyl rubber, diameter 8-inch, length 32 inch |
| Leakage Rate | Less than 0.001 vol %/h |
| Shelving | 2 pieces |
| Pressure Control | PLC controlled, ±10 mbar adjustable, ±12 mbar protection |
| Filter | 0.3 microns, Qty 2 (gas inlet & outlet) |
| Purification Material | Copper catalyst: 5kg, Molecular sieve: 7kg |
| Purification Capacity | Deoxygenation: 60L, Dehydration: 2kg |
| Lighting | LED lighting |
| Regeneration Gas | Mixture of working gas and 5% hydrogen gas |
| Vacuum Pump | 8m³/h, manual or PLC start |
| Vacuum Degree | 5x10-2Pa. |
| Vacuum Pressure Gauge | Mechanical dial, measures transition chamber vacuum |
| Main Valve | DN 40 KF, pneumatic vacuum flapper valve |
| Control Valve | Solenoid integrated valves |
| Control System | Siemens PLC touch screen, self-diagnosis, auto start, cycle & password protection |
| Display System | Displays status, pressure, records |
| Water Analyzer | Range 0 to 1000 ppm |
| Oxygen Analyzer | Range 0 to 1000 ppm, Accuracy ±0.1 ppm |
| Foot Switch | Controls gas replenishment/exhaust, pressure fine-tuning |
| Total Dimension (L×B×H) | 2640 × 790 × 1860mm |
| Packaging Dimension (L×B×H) | 3000 × 850 × 2010 mm |
| Weight | 1030kg |
| Gross Weight | 1100 kg |
Gas Purification Glove Box ADPGB-505 is widely used in pharmaceuticals, biotechnology, and materials research. It is also suitable for advanced energy studies and high-precision laboratory applications.
1. How is pressure controlled in Gas Purification Glove Box ADPGB-505?
Gas Purification Glove Box ADPGB-505 uses a PLC-controlled pressure system allowing precise adjustment within ±10 mbar. Safety protection at ±12 mbar ensures reliable operation, maintaining a stable atmosphere for sensitive samples during laboratory or industrial processes.
2. Does Gas Purification Glove Box ADPGB-505 have a vacuum pump?
Yes, Gas Purification Glove Box ADPGB-505 features an automatic start/stop vacuum pump that efficiently stabilizes the internal atmosphere. It maintains low H?O and O? levels, ensuring high-purity conditions for research, pharmaceutical, and advanced energy applications.
3. What type of filters are used in Gas Purification Glove Box ADPGB-505?
Gas Purification Glove Box ADPGB-505 is equipped with two 0.3-micron high-efficiency filters on the gas inlet and outlet. These filters ensure that the internal atmosphere remains clean, preventing contamination and protecting sensitive samples during handling and experiments.
4. How is visibility inside Gas Purification Glove Box ADPGB-505 ensured?
Gas Purification Glove Box ADPGB-505 features an inclined 8 mm tempered glass sight window combined with bright, low-heat LED lighting. This provides clear visibility throughout the main chamber, allowing safe and precise handling of samples while maintaining a controlled environment.
5. What type of gloves are provided with Gas Purification Glove Box ADPGB-505?
Gas Purification Glove Box ADPGB-505 comes with butyl rubber gloves measuring 8-inch diameter and 32-inch length. These gloves provide chemical resistance, durability, and safe, leak-proof operation for handling samples within the controlled atmosphere of the glove box.
6. What is a Gas Purification Glove Box used for?
A Gas Purification Glove Box provides a fully enclosed, controlled, and inert environment for handling sensitive, reactive, or hazardous materials, protecting both the user and the samples. They are widely used in laboratories, research, and industrial processes requiring precise conditions.
7. How does the gas purification system in Gas Purification Glove Box work?
The gas purification system in Gas Purification Glove Box continuously removes oxygen and moisture from the chamber, maintaining a stable, ultra-pure inert atmosphere. This ensures sensitive materials are protected from contamination, enabling safe and accurate manipulation for experiments, research, or industrial applications.
8. How are materials safely handled inside the Gas Purification Glove Box?
Gas Purification Glove Box have user-friendly glove ports that let you handle materials safely and precisely without exposing them to air. The enclosed, controlled environment prevents contamination of sensitive or reactive substances, ensuring both user safety and sample integrity during experiments or processes.
| Working Gas | Nitrogen, argon (gas purity 99.999%) |
| H₂O and O₂ Index | Less than 1PPM |
| Circulating Capacity | Integrated fan flow rate of 90m³/h |
| Working Gas | Nitrogen, argon (gas purity 99.999%) |
| H₂O and O₂ Index | Less than 1PPM |
| Material | Stainless steel, 3mm thickness |
| Glove Box Type | Stainless Steel Glove Box with H₂O & O₂ Purification System |
| Water Concentration | <1 ppm at 20°C, 1 atm |
| Oxygen Concentration | <1 ppm at 20°C, 1 atm |
| Working Gas | Nitrogen, argon (gas purity 99.999%) |
| H₂O and O₂ Index | Less than 1PPM |
| Circulating Capacity | Integrated fan flow rate of 90m³/h |
| Main Chamber Dimension (L×B×H): | 900 × 600 × 700mm |
| Material Thickness: | 6 mm |
| H₂O and O₂ Content: | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H): | 700 × 450 × 550 mm |
| Antechamber Dimension(L×B×H): | 260 × 260 × 260mm |
| H₂O and O₂ Content: | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H): | 1200 × 800 × 700mm |
| Material Thickness: | 6 mm |
| H₂O and O₂ Content: | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H): | 1000 × 750 × 700 mm |
| Antechamber Dimension(L×B×H): | 260 × 260 × 260mm |
| H₂O and O₂ Content: | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H): | 900 × 500 × 500mm |
| Material Thickness: | 6mm |
| H₂O and O₂ Content: | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H): | 800 × 550 × 600 mm |
| Antechamber Dimension (L×B×H): | 260 × 260 × 260mm |
| H₂O and O₂ Content: | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H): | 300 × 400 × 500mm |
| Material Thickness: | 6 mm |
| H₂O and O₂ Content: | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H): | 900 × 600 × 700 mm |
| Antechamber Dimension(L×B×H): | 260 × 260 × 260mm |
| H₂O and O₂ Content: | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H): | 1000 × 750 × 700mm |
| Material Thickness: | 6 mm |
| H₂O and O₂ Content: | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H): | 800 × 550 × 600mm |
| Material Thickness: | 6mm |
| H₂O and O₂ Content: | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H): | 1200 × 800 × 700 mm |
| Antechamber Dimension(L×B×H): | 260 × 260 × 260mm |
| H₂O and O₂ Content: | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H): | 900 × 500 × 500 mm |
| Antechamber Dimension(L×B×H): | 260 × 260 × 260mm |
| H₂O and O₂ Content: | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H): | 700 × 450 × 550 mm |
| Material Thickness: | 6 mm |
| H₂O and O₂ Content: | 200 to 300 PPM |
| Main Chamber Dimension (L×B×H): | 800 × 650 × 680mm |
| Thickness : | 3mm |
| Vacuum Degree: | -0.1mpa |
| Main Chamber Dimension (L×B×H): | 600 × 450 × 450mm |
| Thickness : | 3mm |
| Vacuum Degree: | -0.1mpa |
| Material: | Stainless steel |
| Air Lock Size: | 200 mm dia. x 260 mm length |
| Main Chamber Size: | 550 mm (W) x 440 mm (D) x 410 mm (H) |
| Main Chamber Dimension (L×B×H): | 1120 × 750 × 900mm |
| Thickness : | 3mm |
| Vacuum Degree: | -0.1mpa |
| Main Chamber Dimension (L×B×H): | 600 × 450 × 450mm |
| Thickness : | 3mm |
| Vacuum Degree: | -0.1mpa |
| Main Chamber Dimension (L×B×H): | 1120 × 750 × 900mm |
| Thickness : | 3mm |
| Vacuum Degree: | -0.1mpa |
| Main Chamber Dimension (L×B×H): | 800 × 650 × 680mm |
| Thickness : | 3mm |
| Vacuum Degree: | -0.1mpa |