Hot Air Sterilizer ADSH-504

Hot Air Sterilizer ADSH-504

Advalab Hot Air Sterilizer ADSH-504 provides precise temperature control from 5°C to 300°C for optimal conditions. Featuring adjustable shelves for flexible storage of different sample sizes. Constructed using stainless-steel, it offers durability and corrosion resistance. Our unit offers a programmable design with 10 segments and 100 cycles for customized settings. The LCD display shows real-time status, allowing for easy monitoring and control. This Hot Air Sterilizer is used in research and laboratories to sterilize tools and equipment.


Volume 284 L
Temperature Range 5 to 300°C
Temperature Resolution 0.1°C
Temperature Fluctuation 0.5°C
Temperature Uniformity 2.2°C
Heating Up Time 20 min
Timer Range 0 to 9999 min
Reservation Range 0 to 9999 min
Number of Shelves 3/9 pc
Load per Shelf 20 kg
Power Consumption 2750 W
Internal Dimensions [W×D×H] 720×530×745 mm
Housing Dimensions [W×D×H] 865×746×1017 mm
Package Dimensions [W×D×H] 985×906×1167 mm
Net Weight 97 kg
Gross Weight 118 kg
  • Preheating chamber design
  • Exhaust outlet
  • Temperature sensor system
  • Easy to operate
  • Air filtration system
  • Countdown timer

Our Hot Air Sterilizer ADSH-504 is used in hospitals, clinics, research labs, and educational institutions for sterilizing instruments, culture media and contaminated waste.

  1. Universal external printer × 1 pc

Frequently Asked Questions of Hot Air Sterilizer ADSH-504

1. How is heat distributed inside a Hot Air Sterilizer?

A Hot Air Sterilizer uses natural or forced air convection to distribute heat evenly. Some Hot Air Sterilizer models come with internal fans for better circulation and more consistent temperature control.

2. What materials are used to build a Hot Air Sterilizer?

A Hot Air Sterilizer is typically made of stainless steel with insulated walls to retain heat. The inner chamber of a Hot Air Sterilizer is designed to withstand high temperatures and prevent heat loss.

3. What is a Hot Air Sterilizer and how does it work?

A Hot Air Sterilizer is a dry heat sterilization device used to sterilize items by circulating hot air. The Hot Air Sterilizer works by raising temperatures to 160°C–180°C for a set time. It kills microorganisms through oxidation without using moisture. It is ideal for glassware, metal, and powders.

4. What materials can be sterilized in a Hot Air Sterilizer?

A Hot Air Sterilizer can sterilize metal instruments, glassware, powders, and oils that withstand dry heat. Materials placed in the Hot Air Sterilizer must be moisture-sensitive and heat-stable.

5. Is a Hot Air Sterilizer safe for sterilizing wrapped instruments?

Yes, a Hot Air Sterilizer can sterilize wrapped instruments if the wrapping is heat-resistant. The Hot Air Sterilizer maintains sterility during storage if the wrapping remains intact. Only use wraps approved for dry heat. Improper wrapping may lead to contamination or melting.

Similar Products of Hot Air Sterilizer

Volume 452 L
Temperature Range 5 to 300°C
Temperature Resolution 0.1°C
Volume 129 L
Temperature Range 5 to 300°C
Temperature Resolution 0.1°C
Volume 64 L
Temperature Range 5 to 300°C
Temperature Resolution 0.1°C
Volume 210 L
Temperature Range 5 to 300°C
Temperature Resolution 0.1°C

Electric Heated Sterilizer

Electric Heated Sterilizer ADEH-501
Capacity:35 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-505
Capacity:120 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-504
Capacity:100 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-506
Capacity:150 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-502
Capacity:50 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-503
Capacity:75 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa

Horizontal Pressure Sterilizer

Horizontal Pressure Sterilizer ADHP-503
Capacity:280 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 60 min
Horizontal Pressure Sterilizer ADHP-501
Capacity:150 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 60 min
Horizontal Pressure Sterilizer ADHP-502
Capacity:200 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 60 min

Horizontal Sterilizer

Horizontal Sterilizer ADHR-502
Capacity:200 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 99 min
Horizontal Sterilizer ADHR-501
Capacity:150 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 99 min
Horizontal Sterilizer ADHR-503
Capacity:280 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 99 min

Glass Bead Sterilizer

Glass Bead Sterilizer ADGBS-501
Temperature Range:100 to 300℃
Temperature Accuracy:≤ 5℃
Heating Rate:≤ 25 min ,Room temperature to 300℃
Glass Bead Sterilizer ADGBS-503
Temperature Range:100℃ to 300℃
Temperature Accuracy:± 5℃
Display Accuracy:1℃
Glass Bead Sterilizer ADGBS-502
Temperature Range:100 to 300℃
Temperature Accuracy:≤ 5℃
Heating Rate:≤ 25 min, Room temperature to 300℃
Glass Bead Sterilizer ADGBS-504
Temperature Range:100℃ to 300℃
Temperature Accuracy:± 5℃
Display Accuracy:1℃

Bacti-Cinerator Sterilizer

Bacti-Cinerator Sterilizer ADBCS-502
Central High Temperature:800℃ ± 50℃
Standby Temperature:400℃ ± 50℃
Heater Head Angle:21°
Bacti-Cinerator Sterilizer ADBCS-503
Central Temperature:825°C ± 25°C
Maximum Outside Diameter of Sterilized Items:ɸ15mm
Heating Zone Length:140 mm
Bacti-Cinerator Sterilizer ADBCS-504
Central Temperature:825°C ± 25°C
Maximum Outside Diameter of Sterilized Items:ɸ35mm
Heating Zone Length:100 mm
Bacti-Cinerator Sterilizer ADBCS-501
Central High Temperature:800℃ ± 50℃
Standby Temperature:400℃ ± 50℃
Heater Head Angle:21°