Hot Air Sterilizer ADSH-505

Hot Air Sterilizer ADSH-505

Advalab Hot Air Sterilizer ADSH-505 operates at a wide temperature range of 5°C to 300°C for reliable performance. Equipped with adjustable shelves, enabling flexible accommodation of various sample sizes. The stainless-steel chamber is durable and easy to clean, with adjustable shelves for various containers. LCD screen allows for easy control and monitoring of both heat and time. Our Hot Air Sterilizer is used across medical, laboratory and research fields for sterilizing instruments.


Volume 452 L
Temperature Range 5 to 300°C
Temperature Resolution 0.1°C
Temperature Fluctuation 0.5°C
Temperature Uniformity 2.5°C
Heating Up Time 22 min
Timer Range 0 to 9999 min
Reservation Range 0 to 9999 min
Number of Shelves 4/13 pc
Load per Shelf 20 kg
Power Consumption 3500 W
Power Supply 220±10 V, 50/60 Hz
Internal Dimensions [W×D×H] 600×580×1300 mm
Housing Dimensions [W×D×H] 774×845×1704 mm
Package Dimensions [W×D×H] 894×1005×1854 mm
Net Weight 145 kg
Gross Weight 176 kg
  • Air filtration system
  • User-friendly interface
  • Temperature sensor system
  • Preheating chamber design
  • Easy to operate
  • Countdown timer

Our Hot Air Sterilizer ADSH-505 is used in research laboratories, and pharmaceutical industries for sterilizing instruments, media, ensuring safe conditions.

Universal external printer × 1 pc

Frequently Asked Questions of Hot Air Sterilizer ADSH-505

1. Can a Hot Air Sterilizer be used for reusable syringes?

Yes, a Hot Air Sterilizer can be used for glass reusable syringes, but not for plastic ones. The Hot Air Sterilizer should only be used with items that can tolerate temperatures of 160°C or higher.

2. How does a Hot Air Sterilizer compare with gas sterilizers?

A Hot Air Sterilizer is safer and more environmentally friendly than gas sterilizers since it doesn’t use toxic chemicals. However, the Hot Air Sterilizer generally takes longer and requires higher temperatures.

3. What is a Hot Air Sterilizer and how does it work?

A Hot Air Sterilizer is a dry heat sterilization device used to sterilize items by circulating hot air. The Hot Air Sterilizer works by raising temperatures to 160°C–180°C for a set time. It kills microorganisms through oxidation without using moisture. It is ideal for glassware, metal, and powders.

4. What materials can be sterilized in a Hot Air Sterilizer?

A Hot Air Sterilizer can sterilize metal instruments, glassware, powders, and oils that withstand dry heat. Materials placed in the Hot Air Sterilizer must be moisture-sensitive and heat-stable.

5. Is a Hot Air Sterilizer safe for sterilizing wrapped instruments?

Yes, a Hot Air Sterilizer can sterilize wrapped instruments if the wrapping is heat-resistant. The Hot Air Sterilizer maintains sterility during storage if the wrapping remains intact. Only use wraps approved for dry heat. Improper wrapping may lead to contamination or melting.

Similar Products of Hot Air Sterilizer

Volume 210 L
Temperature Range 5 to 300°C
Temperature Resolution 0.1°C
Volume 284 L
Temperature Range 5 to 300°C
Temperature Resolution 0.1°C
Volume 64 L
Temperature Range 5 to 300°C
Temperature Resolution 0.1°C
Volume 129 L
Temperature Range 5 to 300°C
Temperature Resolution 0.1°C

Electric Heated Sterilizer

Electric Heated Sterilizer ADEH-505
Capacity:120 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-504
Capacity:100 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-503
Capacity:75 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-506
Capacity:150 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-501
Capacity:35 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-502
Capacity:50 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa

Horizontal Pressure Sterilizer

Horizontal Pressure Sterilizer ADHP-502
Capacity:200 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 60 min
Horizontal Pressure Sterilizer ADHP-503
Capacity:280 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 60 min
Horizontal Pressure Sterilizer ADHP-501
Capacity:150 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 60 min

Horizontal Sterilizer

Horizontal Sterilizer ADHR-503
Capacity:280 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 99 min
Horizontal Sterilizer ADHR-502
Capacity:200 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 99 min
Horizontal Sterilizer ADHR-501
Capacity:150 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 99 min

Glass Bead Sterilizer

Glass Bead Sterilizer ADGBS-502
Temperature Range:100 to 300℃
Temperature Accuracy:≤ 5℃
Heating Rate:≤ 25 min, Room temperature to 300℃
Glass Bead Sterilizer ADGBS-501
Temperature Range:100 to 300℃
Temperature Accuracy:≤ 5℃
Heating Rate:≤ 25 min ,Room temperature to 300℃
Glass Bead Sterilizer ADGBS-503
Temperature Range:100℃ to 300℃
Temperature Accuracy:± 5℃
Display Accuracy:1℃
Glass Bead Sterilizer ADGBS-504
Temperature Range:100℃ to 300℃
Temperature Accuracy:± 5℃
Display Accuracy:1℃

Bacti-Cinerator Sterilizer

Bacti-Cinerator Sterilizer ADBCS-502
Central High Temperature:800℃ ± 50℃
Standby Temperature:400℃ ± 50℃
Heater Head Angle:21°
Bacti-Cinerator Sterilizer ADBCS-501
Central High Temperature:800℃ ± 50℃
Standby Temperature:400℃ ± 50℃
Heater Head Angle:21°
Bacti-Cinerator Sterilizer ADBCS-504
Central Temperature:825°C ± 25°C
Maximum Outside Diameter of Sterilized Items:ɸ35mm
Heating Zone Length:100 mm
Bacti-Cinerator Sterilizer ADBCS-503
Central Temperature:825°C ± 25°C
Maximum Outside Diameter of Sterilized Items:ɸ15mm
Heating Zone Length:140 mm