| Volume | 452 L |
| Temperature Range | 5 to 300°C |
| Temperature Resolution | 0.1°C |
| Temperature Fluctuation | 0.5°C |
| Temperature Uniformity | 2.5°C |
| Heating Up Time | 22 min |
| Timer Range | 0 to 9999 min |
| Reservation Range | 0 to 9999 min |
| Number of Shelves | 4/13 pc |
| Load per Shelf | 20 kg |
| Power Consumption | 3500 W |
| Power Supply | 220±10 V, 50/60 Hz |
| Internal Dimensions [W×D×H] | 600×580×1300 mm |
| Housing Dimensions [W×D×H] | 774×845×1704 mm |
| Package Dimensions [W×D×H] | 894×1005×1854 mm |
| Net Weight | 145 kg |
| Gross Weight | 176 kg |
Our Hot Air Sterilizer ADSH-505 is used in research laboratories, and pharmaceutical industries for sterilizing instruments, media, ensuring safe conditions.
Universal external printer × 1 pc
1. Can a Hot Air Sterilizer be used for reusable syringes?
Yes, a Hot Air Sterilizer can be used for glass reusable syringes, but not for plastic ones. The Hot Air Sterilizer should only be used with items that can tolerate temperatures of 160°C or higher.
2. How does a Hot Air Sterilizer compare with gas sterilizers?
A Hot Air Sterilizer is safer and more environmentally friendly than gas sterilizers since it doesn’t use toxic chemicals. However, the Hot Air Sterilizer generally takes longer and requires higher temperatures.
3. What is a Hot Air Sterilizer and how does it work?
A Hot Air Sterilizer is a dry heat sterilization device used to sterilize items by circulating hot air. The Hot Air Sterilizer works by raising temperatures to 160°C–180°C for a set time. It kills microorganisms through oxidation without using moisture. It is ideal for glassware, metal, and powders.
4. What materials can be sterilized in a Hot Air Sterilizer?
A Hot Air Sterilizer can sterilize metal instruments, glassware, powders, and oils that withstand dry heat. Materials placed in the Hot Air Sterilizer must be moisture-sensitive and heat-stable.
5. Is a Hot Air Sterilizer safe for sterilizing wrapped instruments?
Yes, a Hot Air Sterilizer can sterilize wrapped instruments if the wrapping is heat-resistant. The Hot Air Sterilizer maintains sterility during storage if the wrapping remains intact. Only use wraps approved for dry heat. Improper wrapping may lead to contamination or melting.
| Volume | 210 L |
| Temperature Range | 5 to 300°C |
| Temperature Resolution | 0.1°C |
| Volume | 284 L |
| Temperature Range | 5 to 300°C |
| Temperature Resolution | 0.1°C |
| Volume | 64 L |
| Temperature Range | 5 to 300°C |
| Temperature Resolution | 0.1°C |
| Volume | 129 L |
| Temperature Range | 5 to 300°C |
| Temperature Resolution | 0.1°C |
| Capacity: | 120 L |
| Temperature Range: | 105 ºC to 134 ºC |
| Pressure: | 0.23 Mpa |
| Capacity: | 100 L |
| Temperature Range: | 105 ºC to 134 ºC |
| Pressure: | 0.23 Mpa |
| Capacity: | 75 L |
| Temperature Range: | 105 ºC to 134 ºC |
| Pressure: | 0.23 Mpa |
| Capacity: | 150 L |
| Temperature Range: | 105 ºC to 134 ºC |
| Pressure: | 0.23 Mpa |
| Capacity: | 35 L |
| Temperature Range: | 105 ºC to 134 ºC |
| Pressure: | 0.23 Mpa |
| Capacity: | 50 L |
| Temperature Range: | 105 ºC to 134 ºC |
| Pressure: | 0.23 Mpa |
| Capacity: | 200 L |
| Temperature Range: | 40 ºC to 134 ºC |
| Dry Timer: | 0 to 60 min |
| Capacity: | 280 L |
| Temperature Range: | 40 ºC to 134 ºC |
| Dry Timer: | 0 to 60 min |
| Capacity: | 150 L |
| Temperature Range: | 40 ºC to 134 ºC |
| Dry Timer: | 0 to 60 min |
| Capacity: | 280 L |
| Temperature Range: | 40 ºC to 134 ºC |
| Dry Timer: | 0 to 99 min |
| Capacity: | 200 L |
| Temperature Range: | 40 ºC to 134 ºC |
| Dry Timer: | 0 to 99 min |
| Capacity: | 150 L |
| Temperature Range: | 40 ºC to 134 ºC |
| Dry Timer: | 0 to 99 min |
| Temperature Range: | 100 to 300℃ |
| Temperature Accuracy: | ≤ 5℃ |
| Heating Rate: | ≤ 25 min, Room temperature to 300℃ |
| Temperature Range: | 100 to 300℃ |
| Temperature Accuracy: | ≤ 5℃ |
| Heating Rate: | ≤ 25 min ,Room temperature to 300℃ |
| Temperature Range: | 100℃ to 300℃ |
| Temperature Accuracy: | ± 5℃ |
| Display Accuracy: | 1℃ |
| Temperature Range: | 100℃ to 300℃ |
| Temperature Accuracy: | ± 5℃ |
| Display Accuracy: | 1℃ |
| Central High Temperature: | 800℃ ± 50℃ |
| Standby Temperature: | 400℃ ± 50℃ |
| Heater Head Angle: | 21° |
| Central High Temperature: | 800℃ ± 50℃ |
| Standby Temperature: | 400℃ ± 50℃ |
| Heater Head Angle: | 21° |
| Central Temperature: | 825°C ± 25°C |
| Maximum Outside Diameter of Sterilized Items: | ɸ35mm |
| Heating Zone Length: | 100 mm |
| Central Temperature: | 825°C ± 25°C |
| Maximum Outside Diameter of Sterilized Items: | ɸ15mm |
| Heating Zone Length: | 140 mm |