Horizontal Pressure Sterilizer ADHP-501

Horizontal Pressure Sterilizer ADHP-501

Horizontal Pressure Sterilizer ADHP-501 is a robust and cylindrical sterilizer with a capacity of 150 L operated within the 40 °C to 134 ° C temperature range, designed with stainless steel chamber to ensure long-lasting reliability, durability, and high corrosion resistance. Equipped with safety features like automatic shutoff preventing overload, auto-protection making a safe and user-friendly device.


Capacity 150 L
Temperature Range 40 ºC to 134 ºC
Dry Timer 0 to 60 min
Working Pressure 0.22 Mpa
Temperature 134 ºC
Time Range 0 to 60 min
Heat Average ≤ ± 2 ° C
Power AC380V50Hz/9 KW
Packaging Size 155 × 75 × 185 mm
Dimensions (L×W × H) 140 × 60 × 130 mm
Gross Weight 320 Kg
Net Weight 240 Kg

Horizontal Pressure Sterilizer is widely used in hospitals, research labs, clinics, and laboratories and is also used for sterilizing surgical and dental instruments, glassware, and culture medium.

Similar Products of Horizontal Pressure Sterilizer

Capacity 280 L
Temperature Range 40 ºC to 134 ºC
Dry Timer 0 to 60 min
Capacity 200 L
Temperature Range 40 ºC to 134 ºC
Dry Timer 0 to 60 min

Electric Heated Sterilizer

Electric Heated Sterilizer ADEH-503
Capacity:75 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-505
Capacity:120 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-504
Capacity:100 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-502
Capacity:50 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-501
Capacity:35 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-506
Capacity:150 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa

Horizontal Sterilizer

Horizontal Sterilizer ADHR-503
Capacity:280 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 99 min
Horizontal Sterilizer ADHR-501
Capacity:150 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 99 min
Horizontal Sterilizer ADHR-502
Capacity:200 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 99 min

Glass Bead Sterilizer

Glass Bead Sterilizer ADGBS-504
Temperature Range:100℃ to 300℃
Temperature Accuracy:± 5℃
Display Accuracy:1℃
Glass Bead Sterilizer ADGBS-502
Temperature control range:100 to 300 C
Temperature accuracy:within 5 C
Heating time (room temperature to 300 C):up to 25 min
Glass Bead Sterilizer ADGBS-501
Temperature control range:100 to 300 C
Temperature accuracy:within 5 C
Heating time (room temperature to 300 C):up to 25 min
Glass Bead Sterilizer ADGBS-503
Temperature Range:100℃ to 300℃
Temperature Accuracy:± 5℃
Display Accuracy:1℃

Bacti-Cinerator Sterilizer

Bacti-Cinerator Sterilizer ADBCS-501
Central High Temperature:800℃ ± 50℃
Standby Temperature:400℃ ± 50℃
Heater Head Angle:21°
Bacti-Cinerator Sterilizer ADBCS-503
Central Temperature:825°C ± 25°C
Maximum Outside Diameter of Sterilized Items:ɸ15mm
Heating Zone Length:140 mm
Bacti-Cinerator Sterilizer ADBCS-504
Central Temperature:825°C ± 25°C
Maximum Outside Diameter of Sterilized Items:ɸ35mm
Heating Zone Length:100 mm
Bacti-Cinerator Sterilizer ADBCS-502
Central High Temperature:800℃ ± 50℃
Standby Temperature:400℃ ± 50℃
Heater Head Angle:21°

Hot Air Sterilizer

Hot Air Sterilizer ADSH-502
Volume:129 L
Temperature Range:5 to 300°C
Temperature Resolution:0.1°C
Hot Air Sterilizer ADSH-504
Volume:284 L
Temperature Range:5 to 300°C
Temperature Resolution:0.1°C
Hot Air Sterilizer ADSH-503
Volume:210 L
Temperature Range:5 to 300°C
Temperature Resolution:0.1°C
Hot Air Sterilizer ADSH-501
Volume:64 L
Temperature Range:5 to 300°C
Temperature Resolution:0.1°C
Hot Air Sterilizer ADSH-505
Volume:452 L
Temperature Range:5 to 300°C
Temperature Resolution:0.1°C