| Temperature Range | 100℃ to 300℃ |
| Temperature Accuracy | ± 5℃ |
| Display Accuracy | 1℃ |
| Time Range | 1min to 99h59min / infinite |
| Heating Time | ≤ 25min (RT. to 300℃) |
| Voltage | AC 110V or 220V, 50/60Hz |
| Maximum Power | 250 W |
| Chamber Volume (diameter x depth) | Φ 40 x 140 mm |
| Glass Beads Capacity | 300 g |
| Dimensions (W x D x H) | 176 x 135 x 249.5 mm |
| Weight | 3.3 kg |
Glass Bead Sterilizer ADGBS-504 is used for the rapid sterilization of small surgical instruments such as forceps, scissors, and needles. Its compact design and chemical-free operation make it ideal for use in medical, dental, and laboratory environments.
1. What is the primary use of the Glass Bead Sterilizer ADGBS-504?
Glass Bead Sterilizer ADGBS-504 is to sterilize small surgical and laboratory instruments quickly and effectively. It is ideal for tools like forceps, scissors, and needles. This unit uses high-temperature glass beads to eliminate microorganisms without chemicals. This makes it suitable for medical, dental, and research environments.
2. Does Glass Bead Sterilizer ADGBS-504 require chemicals or gas?
Glass Bead Sterilizer ADGBS-504 does not require any chemicals or gas for operation. It uses high-temperature glass beads to sterilize instruments through dry heat. This method is clean, safe, and environmentally friendly. The absence of open flames or toxic substances makes it ideal for enclosed spaces like laminar flow hoods. It ensures effective sterilization while maintaining a hazard-free working environment.
3. Are the glass beads of Glass Bead Sterilizer ADGBS-504 reusable?
Glass Beads used in Glass Bead Sterilizer ADGBS-504 are reusable. They are made from heat-resistant materials suitable for repeated sterilization cycles. Regular cleaning is recommended to maintain their effectiveness. Over time, beads may need replacement if they show signs of wear or discoloration. Proper maintenance ensures consistent sterilization performance and extends bead lifespan.
4. How long does Glass Bead Sterilizer ADGBS-504 take to heat up to sterilization temperature?
Glass Bead Sterilizer ADGBS-504 is designed for efficient and quick heating. It takes 25 minutes or less to reach 300°C from room temperature. This fast-heating time ensures minimal waiting before sterilization can begin. The efficient thermal system supports consistent and uniform temperature buildup. It enhances workflow efficiency in labs and clinical settings.
5. How often should the Glass Bead Sterilizer ADGBS-504 be maintained?
Glass Bead Sterilizer ADGBS-504 requires minimal but regular maintenance to ensure optimal performance. The glass beads should be cleaned every couple of weeks and replaced every 3 to 6 months, depending on usage. The inner chamber should be kept free from debris or residue. Always allow the unit to cool before cleaning or handling the beads. Routine maintenance extends its lifespan and maintains effective sterilization.
| Temperature Range | 100 to 300℃ |
| Temperature Accuracy | ≤ 5℃ |
| Heating Rate | ≤ 25 min, Room temperature to 300℃ |
| Temperature Range | 100 to 300℃ |
| Temperature Accuracy | ≤ 5℃ |
| Heating Rate | ≤ 25 min ,Room temperature to 300℃ |
| Temperature Range | 100℃ to 300℃ |
| Temperature Accuracy | ± 5℃ |
| Display Accuracy | 1℃ |
| Capacity: | 120 L |
| Temperature Range: | 105 ºC to 134 ºC |
| Pressure: | 0.23 Mpa |
| Capacity: | 35 L |
| Temperature Range: | 105 ºC to 134 ºC |
| Pressure: | 0.23 Mpa |
| Capacity: | 100 L |
| Temperature Range: | 105 ºC to 134 ºC |
| Pressure: | 0.23 Mpa |
| Capacity: | 150 L |
| Temperature Range: | 105 ºC to 134 ºC |
| Pressure: | 0.23 Mpa |
| Capacity: | 75 L |
| Temperature Range: | 105 ºC to 134 ºC |
| Pressure: | 0.23 Mpa |
| Capacity: | 50 L |
| Temperature Range: | 105 ºC to 134 ºC |
| Pressure: | 0.23 Mpa |
| Capacity: | 150 L |
| Temperature Range: | 40 ºC to 134 ºC |
| Dry Timer: | 0 to 60 min |
| Capacity: | 200 L |
| Temperature Range: | 40 ºC to 134 ºC |
| Dry Timer: | 0 to 60 min |
| Capacity: | 280 L |
| Temperature Range: | 40 ºC to 134 ºC |
| Dry Timer: | 0 to 60 min |
| Capacity: | 280 L |
| Temperature Range: | 40 ºC to 134 ºC |
| Dry Timer: | 0 to 99 min |
| Capacity: | 200 L |
| Temperature Range: | 40 ºC to 134 ºC |
| Dry Timer: | 0 to 99 min |
| Capacity: | 150 L |
| Temperature Range: | 40 ºC to 134 ºC |
| Dry Timer: | 0 to 99 min |
| Central Temperature: | 825°C ± 25°C |
| Maximum Outside Diameter of Sterilized Items: | ɸ35mm |
| Heating Zone Length: | 100 mm |
| Central High Temperature: | 800℃ ± 50℃ |
| Standby Temperature: | 400℃ ± 50℃ |
| Heater Head Angle: | 21° |
| Central Temperature: | 825°C ± 25°C |
| Maximum Outside Diameter of Sterilized Items: | ɸ15mm |
| Heating Zone Length: | 140 mm |
| Central High Temperature: | 800℃ ± 50℃ |
| Standby Temperature: | 400℃ ± 50℃ |
| Heater Head Angle: | 21° |
| Volume: | 284 L |
| Temperature Range: | 5 to 300°C |
| Temperature Resolution: | 0.1°C |
| Volume: | 64 L |
| Temperature Range: | 5 to 300°C |
| Temperature Resolution: | 0.1°C |
| Volume: | 452 L |
| Temperature Range: | 5 to 300°C |
| Temperature Resolution: | 0.1°C |
| Volume: | 210 L |
| Temperature Range: | 5 to 300°C |
| Temperature Resolution: | 0.1°C |
| Volume: | 129 L |
| Temperature Range: | 5 to 300°C |
| Temperature Resolution: | 0.1°C |