Glass Bead Sterilizer ADGBS-502

Glass Bead Sterilizer ADGBS-502

Advalab Glass Bead Sterilizer ADGBS-502 holds 300 g of glass beads in a stainless steel inner container for small metal laboratory tools, and the beads are supplied with the unit. Easy operation starts with setting the glass bead sterilizer temperature from 100 to 300°C on the heating device with thermostat control, then following the real-time temperature display and countdown. Built-in over-temperature protection keeps this laboratory glass bead sterilizer from overheating. Once the beads reach the set temperature, this hot bead sterilizer is ready as a dry glass bead sterilizer.


Temperature control range 100 to 300 C
Temperature accuracy within 5 C
Heating time (room temperature to 300 C) up to 25 min
Voltage AC 100 to 120 V / 200 to 240 V, 50 to 60 Hz
Maximum power 250 W
Container size diameter 40 x 140 mm
Glass bead capacity 300 g
Glass bead diameter 3.0 mm
Exterior dimensions 135 x 130 x 225 mm
Packing dimensions 260 x 235 x 320 mm
Net weight 2.5 kg
Gross weight 3.8 kg

Frequently Asked Questions of Glass Bead Sterilizer ADGBS-502

1. What is a Glass Bead Sterilizer?

A Glass Bead Sterilizer is a device used to quickly and effectively sterilize small metal instruments by heating glass beads. The sterilizer generates a sterile environment by applying dry heat, which is transferred from the heated beads to the surface of the instruments. This process ensures the instruments are free from bacteria, viruses, and other harmful microorganisms.

2. What are the advantages of using a Glass Bead Sterilizer?

Advantages of using a Glass Bead Sterilizer: • Speed: Sterilization is fast, often requiring only seconds. • No Chemicals: No need for chemical disinfectants, making it environmentally friendly and safe. • Cost-Effective: It is affordable and require minimal maintenance. • Portable: It is compact and easy to transport.

3. How long does it take to sterilize instruments with a Glass Bead Sterilizer?

Sterilizing instruments in a Glass Bead Sterilizer usually takes between 5 to 10 seconds, as the heat from the beads rapidly transfers to the instrument. The time may vary depending on the size and material of the tool, with larger or denser items requiring slightly more time. The temperature of the beads, typically ranging from 100°C to 300°C, affects the sterilization time, with higher temperatures speeding up the process.

4. How do I maintain a Glass Bead Sterilizer?

• Clean the Beads Regularly: Remove any debris from the glass beads to ensure efficient sterilization. • Check Temperature: Regularly check the temperature settings to ensure they are functioning properly. • Replace the Beads if Necessary: Over time, the glass beads may wear down or become dirty. If this happens, they should be replaced to ensure the sterilizer works effectively.

5. Are Glass Bead Sterilizers safe to use?

Yes, Glass Bead Sterilizers are safe when used correctly. They should be placed on a stable, heat-resistant surface. Never open the sterilizer while it's in operation to avoid exposure to high heat. Always ensure the device is properly maintained, cleaned, and that it’s used in a well-ventilated area to prevent overheating. Keep the sterilizer away from flammable materials, and ensure it's turned off and cooled down after each use to avoid burns or other injuries.

Similar Products of Glass Bead Sterilizer

Temperature Range 100℃ to 300℃
Temperature Accuracy ± 5℃
Display Accuracy 1℃
Temperature control range 100 to 300 C
Temperature accuracy within 5 C
Heating time (room temperature to 300 C) up to 25 min
Temperature Range 100℃ to 300℃
Temperature Accuracy ± 5℃
Display Accuracy 1℃

Electric Heated Sterilizer

Electric Heated Sterilizer ADEH-502
Capacity:50 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-504
Capacity:100 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-505
Capacity:120 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-503
Capacity:75 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-506
Capacity:150 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa
Electric Heated Sterilizer ADEH-501
Capacity:35 L
Temperature Range:105 ºC to 134 ºC
Pressure:0.23 Mpa

Horizontal Pressure Sterilizer

Horizontal Pressure Sterilizer ADHP-502
Capacity:200 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 60 min
Horizontal Pressure Sterilizer ADHP-501
Capacity:150 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 60 min
Horizontal Pressure Sterilizer ADHP-503
Capacity:280 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 60 min

Horizontal Sterilizer

Horizontal Sterilizer ADHR-503
Capacity:280 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 99 min
Horizontal Sterilizer ADHR-501
Capacity:150 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 99 min
Horizontal Sterilizer ADHR-502
Capacity:200 L
Temperature Range:40 ºC to 134 ºC
Dry Timer:0 to 99 min

Bacti-Cinerator Sterilizer

Bacti-Cinerator Sterilizer ADBCS-501
Central High Temperature:800℃ ± 50℃
Standby Temperature:400℃ ± 50℃
Heater Head Angle:21°
Bacti-Cinerator Sterilizer ADBCS-503
Central Temperature:825°C ± 25°C
Maximum Outside Diameter of Sterilized Items:ɸ15mm
Heating Zone Length:140 mm
Bacti-Cinerator Sterilizer ADBCS-502
Central High Temperature:800℃ ± 50℃
Standby Temperature:400℃ ± 50℃
Heater Head Angle:21°
Bacti-Cinerator Sterilizer ADBCS-504
Central Temperature:825°C ± 25°C
Maximum Outside Diameter of Sterilized Items:ɸ35mm
Heating Zone Length:100 mm

Hot Air Sterilizer

Hot Air Sterilizer ADSH-502
Volume:129 L
Temperature Range:5 to 300°C
Temperature Resolution:0.1°C
Hot Air Sterilizer ADSH-504
Volume:284 L
Temperature Range:5 to 300°C
Temperature Resolution:0.1°C
Hot Air Sterilizer ADSH-505
Volume:452 L
Temperature Range:5 to 300°C
Temperature Resolution:0.1°C
Hot Air Sterilizer ADSH-501
Volume:64 L
Temperature Range:5 to 300°C
Temperature Resolution:0.1°C
Hot Air Sterilizer ADSH-503
Volume:210 L
Temperature Range:5 to 300°C
Temperature Resolution:0.1°C