Multi-Channel Pipette ADMCP-504

Multi-Channel Pipette ADMCP-504

Multi-Channel Pipette ADMCP-504 comes with a volume range of 10 to 100 µl for handling very small liquid capacity with high precision. It includes a smooth plunger mechanism to ensure the exact dispensing of liquids The pipette features a digital display, enabling accurate and easy-to-read volume settings. This unit comes with autoclavable components, allowing for sterilization and safe use in sensitive environments. Our Multi-Channel Pipette is used in diagnostics, pharmaceuticals, and research labs for liquid handling.

USD 340.00
Volume Range 10 to 100 µl
Increment 1 µl
Test Volume 100 µl
50 µl
10 µl
Accuracy 0.80 % at 100 µl
1.00 % at 100 µl
3.00 % at 100 µl
Precision 0.15 % at 100 µl
0.40 % at 100 µl
1.50 % at 100 µl
Channel 8
Gross Weight 16 Kg
Dimensions (L×B×H) 0.56×0.36×0.28 m³
  • Adjustable volume
  • Maintenance friendly
  • Multiple channels
  • Reduced strain
  • Tip ejection system

Our Multi-Channel Pipette ADMCP-504 is widely used for high-throughput liquid handling in applications such as microplate filling, serial dilutions and molecular biology assays.

Frequently Asked Questions of Multi-Channel Pipette ADMCP-504

1. How do you prevent cross-contamination when using a Multi-Channel Pipette?

To prevent cross-contamination, always use sterile, filtered, and disposable tips. Never reuse tips across different reagents or samples. Avoid touching the tips to non-sterile surfaces. Perform regular decontamination of the pipette, especially if working with nucleic acids or proteins. Use proper pipetting technique to avoid aerosols or dripping. Employ reverse pipetting when dealing with viscous or volatile liquids.

2. Why is it important to pre-wet pipette tips when using a Multi-Channel Pipette?

Pre-wetting tips involves aspirating and dispensing the liquid once or twice before the actual measurement. This step conditions the inside of the tip, saturating it with the liquid’s vapor and reducing surface tension effects. It improves accuracy and consistency, especially for small volumes or volatile solvents. In Multi-Channel Pipette, pre-wetting helps ensure that all channels aspirate an equal volume, minimizing variability across wells.

3. What is a Multi-Channel Pipette and how does it differ from a Single-Channel Pipette?

A Multi-Channel Pipette is a laboratory instrument that allows simultaneous dispensing of liquids into multiple wells, typically 8 or 12 at a time, making it ideal for use with microplates such as 96-well or 384-well plates. Unlike a Single-Channel Pipette that transfers liquid into one tube or well at a time, a Multi-Channel Pipette increases throughput and ensures consistency across samples, which is crucial for high-throughput screening, ELISA, and PCR applications.

4. What are the advantages of using a Multi-Channel Pipette in ELISA or PCR workflows?

Multi-Channel Pipette greatly enhance the efficiency and accuracy of ELISA and PCR workflows by allowing simultaneous liquid transfer into multiple wells of a microplate. This reduces hands-on time and ensures uniform handling of reagents across wells, which is essential for reproducible results. In ELISA, consistent reagent delivery minimizes variability in optical density readings. In PCR, even loading of master mixes ensures uniform amplification.

5. How to calibrate a Multi-Channel Pipette?

Calibration of a Multi-Channel Pipette involves checking the volume accuracy and precision of each channel. This is typically done gravimetrically by dispensing water into a weighing boat on an analytical balance and recording the weight to infer volume (assuming the density of water). Each channel should be tested individually to ensure uniform performance. The pipette should meet manufacturer-defined accuracy and precision specifications.

Similar Products of Multi-Channel Pipette

Volume Range 0.5 to 10 µl
Increment 0.1 µl
Test Volume 10 µl
5 µl
1 µl

USD 350.00

Volume Range 30 to 300 µl
Increment 5 µl
Test Volume 300 µl
150 µl
30 µl

USD 340.00

Volume Range 20 to 200 µl
Increment 1 µl
Test Volume 200 µl
100 µl
20 µl

USD 340.00

Volume Range 2 to 20 µl
Increment 0.5 µl
Test Volume 20 µl
10 µl
2 µl

USD 350.00

Electronic Pipette

Electronic Pipette ADEP-502
Volume Range:5 to 120µl
Increment:0.10 µl
Test Volume:12 µl<br/> 60 µl<br/> 120 µl

USD 700.00

Electronic Pipette ADEP-505
Volume Range:100to5000µl
Increment:5.00µl
Test Volume:5000µl<br/> 2500µl<br/> 500µl

USD 630.00

Electronic Pipette ADEP-501
Volume Range:0.1 to 10 µl
Increment:0.01 µl
Test Volume:10 µl <br/> 5 µl <br/> 1 µl

USD 700.00

Electronic Pipette ADEP-506
Volume Range:500 to 10000 µl
Increment:10.00 µl
Test Volume:10000 µl <br/> 5000 µl <br/> 1000 µl

USD 700.00

Electronic Pipette ADEP-503
Volume Range:10 to 300µl
Increment:0.20µl
Test Volume:30µl<br>150µl<br>300µl

USD 700.00

Electronic Pipette ADEP-504
Volume Range:50-1000µl
Increment:1.00µl
Test Volume:100µl<br/> 500µl<br/> 1000µl

USD 700.00

Mini Fixed Volume Pipette

Mini Fixed Volume Pipette ADFVP-502
Volume Range:10µl
Accuracy:±1.2% at 10µl
Precision:±0.8% at 10µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-501
Volume Range:5µl
Accuracy:±2.5% at 5µl
Precision :±1.5% at 5µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-507
Volume Range:100µl
Accuracy:±0.8% at 100µl
Precision:±0.3% at 100µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-506
Volume Range:75µl
Accuracy:±0.8% at 75µl
Precision :±0.3% at 75µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-509
Volume Range:300µl
Accuracy:±0.8% at 300µl
Precision:±0.3% at 300µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-508
Volume Range:200µl
Accuracy:±0.8% at 200µl
Precision:±0.3% at 200µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-505
Volume Range:50µl
Accuracy:±1% at 50µl
Precision:±0.4% at 50µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-503
Volume Range:20µl
Accuracy:±1.0% at 20µl
Precision:±0.5% at 20µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-504
Volume Range:30µl
Accuracy:±1.0% at 30µl
Precision :±0.4% at 30µl

USD 310.00

Single Channel Variable Pipette

Single Channel Variable Pipette ADCVP-512
Volume Range:0.5 to 10 µl
Increment:0.02 µl
Test Volume:1 µl<br/> 5µl<br/> 10 µl

USD 510.00

Single Channel Variable Pipette ADCVP-515
Volume Range:20 to 200 µl
Increment:0.2 µl
Test Volume:20 µl<br/> 100 µl<br/> 200 µl

USD 510.00

Single Channel Variable Pipette ADCVP-506
Volume Range:20 to 200 µl
Increment:1 µl
Test Volume:200µl<br/> 100µl<br/> 20 µl

USD 310.00

Single Channel Variable Pipette ADCVP-516
Volume Range:100 to 1000 µl
Increment:2 µl
Test Volume:100µl<br/> 500µl<br/> 1000 µl

USD 510.00

Single Channel Variable Pipette ADCVP-510
Volume Range:1 to 10 µl
Increment:0.1 µl
Test Volume:10 µl<br/> 5µl<br/> 1 µl

USD 310.00

Single Channel Variable Pipette ADCVP-518
Volume Range:1 to 10 µl
Increment:20 µl
Test Volume:1 µl<br/> 5µl<br/> 10 µl

USD 510.00

Single Channel Variable Pipette ADCVP-517
Volume Range:0.5 to 5 µl
Increment:20 µl
Test Volume:1000 µl<br/> 2500 µl<br/> 5000 µl

USD 510.00

Single Channel Variable Pipette ADCVP-514
Volume Range:10 to 100 µl
Increment:0.2 µl
Test Volume:10 µl<br/> 50 µl<br/> 100 µl

USD 510.00

Single Channel Variable Pipette ADCVP-511
Volume Range:0.2 to 2 µl
Increment:0.002 µl
Test Volume:0.2 µl<br/> 0.5µl<br/> 2 µl

USD 510.00

Single Channel Variable Pipette ADCVP-508
Volume Range:100 to 1000 µl
Increment:5 µl
Test Volume:1000 µl<br/> 500µl<br/> 100 µl

USD 310.00

Single Channel Variable Pipette ADCVP-501
Volume Range:0.1 to 2.5 µl
Increment:0.05 µl
Test Volume:0.25 µl<br/> 1.25 µl<br/> 2.5 µl

USD 310.00

Single Channel Variable Pipette ADCVP-504
Volume Range:5 to 50 µl
Increment:0.5 µl
Test Volume:50 µl<br/> 25 µl<br/> 5 µl

USD 310.00

Single Channel Variable Pipette ADCVP-505
Volume Range:10 to 100 µl
Increment:1 µl
Test Volume:100 µl<br/> 50 µl<br/> 10 µl

USD 310.00

Single Channel Variable Pipette ADCVP-507
Volume Range:30to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 30 µl

USD 310.00

Single Channel Variable Pipette ADCVP-502
Volume Range:0.5 to 10 µl
Increment:0.1 µl
Test Volume:1 µl<br/> 5µl<br/> 1 µl

USD 310.00

Single Channel Variable Pipette ADCVP-509
Volume Range:1 to 5 µl
Increment:0.05 µl
Test Volume:5 µl<br/> 2.5µl<br/> 1 µl

USD 310.00

Single Channel Variable Pipette ADCVP-513
Volume Range:2 to 20 µl
Increment:0.02 µl
Test Volume:2 µl<br/> 10 µl<br/> 20 µl

USD 510.00

Single Channel Variable Pipette ADCVP-503
Volume Range:2to 20 µl
Increment:0.5 µl
Test Volume:20 µl<br/> 10 µl<br/> 2 µl

USD 310.00

Pipette With Switch

Pipette With Switch ADPWS-507
Volume Range:1 to 5µl
Increment:50µl
Test Volume:5000µl <br/> 2500µl <br/> 1000µl

USD 590.00

Pipette With Switch ADPWS-506
Volume Range:10 to 1000µl
Increment:5µl
Test Volume:1000µl <br/> 500µl <br/> 100µl

USD 590.00

Pipette With Switch ADPWS-503
Volume Range:5 to 50µl
Increment:0.5µl
Test Volume:50µl <br/> 25µl <br/> 5µl

USD 590.00

Pipette With Switch ADPWS-505
Volume Range:20 to 200µl
Increment:1µl
Test Volume:200µl <br/> 100µl <br/> 20µl

USD 590.00

Pipette With Switch ADPWS-502
Volume Range:2 to 20µl
Increment:0.5µl
Test Volume:20µl <br/> 10µl <br/> 2µl

USD 590.00

Pipette With Switch ADPWS-504
Volume Range:10 to 100µl
Increment:1µl
Test Volume:100µl <br/> 50µl <br/> 10µl

USD 590.00

Pipette With Switch ADPWS-501
Volume Range:0.5 to 10µl
Increment:0.1µl
Test Volume:10µl <br/> 5µl <br/> 1µl

USD 590.00

Fixed Volume Pipette

Fixed Volume Pipette ADFPT-504
Volume:25µl
Accuracy:±3.00µl
Precision:≤1.50µl

USD 240.00

Fixed Volume Pipette ADFPT-505
Volume:50µl
Accuracy:±3.00µl
Precision:≤1.50µl

USD 240.00

Fixed Volume Pipette ADFPT-501
Volume:5µl
Accuracy:±8.00µl
Precision:≤5.00µl

USD 240.00

Fixed Volume Pipette ADFPT-503
Volume:20µl
Accuracy:±3.00µl
Precision:≤1.50µl

USD 240.00

Fixed Volume Pipette ADFPT-506
Volume:100µl
Accuracy:±2.00µl
Precision:≤1.00µl

USD 240.00

Fixed Volume Pipette ADFPT-502
Volume:10µl
Accuracy:±4.80µl
Precision:≤2.50µl

USD 240.00