Single Channel Variable Pipette ADCVP-501
Single Channel Variable Pipette ADCVP-501(Front View)
Single Channel Variable Pipette ADCVP-501(Front View)

Single Channel Variable Pipette ADCVP-501

Single Channel Variable Pipette ADCVP-501 comes with a volume range of 0.1 to 2.5 µl for handling very small liquid capacity with high precision. The pipette features a digital display, enabling accurate and easy-to-read volume settings. It includes a smooth plunger mechanism to ensure the exact dispensing of liquids. This unit comes with autoclavable components, allowing for sterilization and safe use in sensitive environments. Our Single Channel Variable Pipette is used in diagnostics, pharmaceuticals, and research labs for liquid handling.

Volume Range 0.1 to 2.5 µl
Increment 0.05 µl
Test Volume 0.25 µl
1.25 µl
2.5 µl
Accuracy ±2.50% at 2.5 µl
±3.00% at 2.5 µl
±12.00% at 2.5 µl
Precision ±2.00% at 2.5 µl
±3.00% at 2.5 µl
±6.00%
Channel 1
Dimensions (L×B×H) 490×400×290 mm
  • Adjustable volume control
  • Single channel design
  • Ejector mechanism
  • Autoclavable components
  • Calibration adjustment

Our Single Channel Variable Pipette ADCVP-501 is used in biotechnology diagnostics, and research for precise liquid handling in sample preparation, reagent dispensing, and DNA/RNA work.

Frequently Asked Questions of Single Channel Variable Pipette ADCVP-501

1. What is a Single Channel Variable Pipette?

A single channel variable pipette is a precision laboratory instrument used to accurately measure and transfer a specific volume of liquid, typically in the microliter (µL) range. "Single channel" means it dispenses through one nozzle, and "variable" indicates the volume can be adjusted within a specified range (e.g., 10–100 µL). It is commonly used in biology, chemistry, and clinical labs.

2. How to set the desired volume on a Single Channel Variable Pipette?

To set the desired volume, rotate the volume adjustment knob or plunger top until the digital readout displays the required value. Ensure the pipette is within its specified volume range (e.g., do not set a 10–100 µL pipette to 150 µL). Always approach the final setting from a higher value to reduce mechanical backlash and improve accuracy.

3. How to calibrate a Single Channel Variable Pipette?

Pipette calibration typically involves gravimetric testing, where known volumes of water are dispensed and weighed on an analytical balance. The weight is converted to volume (considering water density and temperature), and the accuracy/precision is calculated. Any deviation beyond tolerance requires adjustment or servicing.

4. What maintenance is required for a Single Channel Variable Pipette?

Routine maintenance includes cleaning the exterior, checking the piston and seal for wear, autoclaving the lower part (if autoclavable), lubricating internal parts if necessary, and recalibrating regularly. Maintenance ensures reliable performance and prolongs pipette life.

5. What is the proper way to hold a Single Channel Variable Pipette?

Hold the Single Channel Variable Pipette vertically when aspirating and at a slight angle (10–45°) when dispensing close to the vessel wall. The thumb should control the plunger, and the hand should remain relaxed to avoid fatigue during repetitive use. A good grip minimizes hand strain and improves control.

Similar Products of Single Channel Variable Pipette

Volume Range 0.2 to 2 µl
Increment 0.002 µl
Test Volume 0.2 µl
0.5µl
2 µl
Volume Range 2 to 20 µl
Increment 0.02 µl
Test Volume 2 µl
10 µl
20 µl
Volume Range 5 to 50 µl
Increment 0.5 µl
Test Volume 50 µl
25 µl
5 µl
Volume Range 0.5 to 10 µl
Increment 0.02 µl
Test Volume 1 µl
5µl
10 µl

Electronic Pipette

Electronic Pipette ADEP-503
Volume Range:10 to 300µl
Increment:0.20µl
Test Volume:30µl<br>150µl<br>300µl
Electronic Pipette ADEP-505
Volume Range:100to5000µl
Increment:5.00µl
Test Volume:5000µl<br/> 2500µl<br/> 500µl
Electronic Pipette ADEP-501
Volume Range:0.1 to 10 µl
Increment:0.01 µl
Test Volume:10 µl <br/> 5 µl <br/> 1 µl
Electronic Pipette ADEP-502
Volume Range:5 to 120µl
Increment:0.10 µl
Test Volume:12 µl<br/> 60 µl<br/> 120 µl
Electronic Pipette ADEP-504
Volume Range:50-1000µl
Increment:1.00µl
Test Volume:100µl<br/> 500µl<br/> 1000µl
Electronic Pipette ADEP-506
Volume Range:500 to 10000 µl
Increment:10.00 µl
Test Volume:10000 µl <br/> 5000 µl <br/> 1000 µl

Mini Fixed Volume Pipette

Mini Fixed Volume Pipette ADFVP-508
Volume Range:200µl
Accuracy:±0.8% at 200µl
Precision:±0.3% at 200µl
Mini Fixed Volume Pipette ADFVP-507
Volume Range:100µl
Accuracy:±0.8% at 100µl
Precision:±0.3% at 100µl
Mini Fixed Volume Pipette ADFVP-509
Volume Range:300µl
Accuracy:±0.8% at 300µl
Precision:±0.3% at 300µl
Mini Fixed Volume Pipette ADFVP-506
Volume Range:75µl
Accuracy:±0.8% at 75µl
Precision :±0.3% at 75µl
Mini Fixed Volume Pipette ADFVP-501
Volume Range:5µl
Accuracy:±2.5% at 5µl
Precision :±1.5% at 5µl
Mini Fixed Volume Pipette ADFVP-504
Volume Range:30µl
Accuracy:±1.0% at 30µl
Precision :±0.4% at 30µl
Mini Fixed Volume Pipette ADFVP-503
Volume Range:20µl
Accuracy:±1.0% at 20µl
Precision:±0.5% at 20µl
Mini Fixed Volume Pipette ADFVP-502
Volume Range:10µl
Accuracy:±1.2% at 10µl
Precision:±0.8% at 10µl
Mini Fixed Volume Pipette ADFVP-505
Volume Range:50µl
Accuracy:±1% at 50µl
Precision:±0.4% at 50µl

Multi-Channel Pipette

Multi-Channel Pipette ADMCP-511
Volume Range:10 to 100 µl
Increment:1 µl
Test Volume:100 µl<br/> 50 µl<br/> 2 µl
Multi-Channel Pipette ADMCP-512
Volume Range:20 to 200 µl
Increment:1 µl
Test Volume:200 µl<br/> 100 µl<br/> 10µl
Multi-Channel Pipette ADMCP-503
Volume Range:5 to 50 µl
Increment:0.5 µl
Test Volume:50 µl<br/> 25 µl<br/> 5 µl
Multi-Channel Pipette ADMCP-502
Volume Range:2 to 20 µl
Increment:0.5 µl
Test Volume:20 µl<br/> 10 µl<br/> 2 µl
Multi-Channel Pipette ADMCP-513
Volume Range:30 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 30µl
Multi-Channel Pipette ADMCP-505
Volume Range:20 to 200 µl
Increment:1 µl
Test Volume:200 µl<br/> 100 µl<br/> 20 µl
Multi-Channel Pipette ADMCP-504
Volume Range:10 to 100 µl
Increment:1 µl
Test Volume:100 µl<br/> 50 µl<br/> 10 µl
Multi-Channel Pipette ADMCP-508
Volume Range:0.5 to 10 µl
Increment:0.1 µl
Test Volume:10 µl<br/> 5 µl<br/> 1 µl
Multi-Channel Pipette ADMCP-507
Volume Range:50 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 50 µl
Multi-Channel Pipette ADMCP-514
Volume Range:50 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 50µl
Multi-Channel Pipette ADMCP-509
Volume Range:2 to 20 µl
Increment:0.5 µl
Test Volume:20 µl<br/> 10 µl<br/> 2 µl
Multi-Channel Pipette ADMCP-510
Volume Range:5 to 50 µl
Increment:0.5 µl
Test Volume:50 µl<br/> 25 µl<br/> 5 µl
Multi-Channel Pipette ADMCP-501
Volume Range:0.5 to 10 µl
Increment:0.1 µl
Test Volume:10 µl<br/> 5 µl<br/> 1 µl
Multi-Channel Pipette ADMCP-506
Volume Range:30 to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 30 µl

Pipette With Switch

Pipette With Switch ADPWS-505
Volume Range:20 to 200µl
Increment:1µl
Test Volume:200µl <br/> 100µl <br/> 20µl
Pipette With Switch ADPWS-501
Volume Range:0.5 to 10µl
Increment:0.1µl
Test Volume:10µl <br/> 5µl <br/> 1µl
Pipette With Switch ADPWS-507
Volume Range:1 to 5µl
Increment:50µl
Test Volume:5000µl <br/> 2500µl <br/> 1000µl
Pipette With Switch ADPWS-503
Volume Range:5 to 50µl
Increment:0.5µl
Test Volume:50µl <br/> 25µl <br/> 5µl
Pipette With Switch ADPWS-506
Volume Range:10 to 1000µl
Increment:5µl
Test Volume:1000µl <br/> 500µl <br/> 100µl
Pipette With Switch ADPWS-504
Volume Range:10 to 100µl
Increment:1µl
Test Volume:100µl <br/> 50µl <br/> 10µl
Pipette With Switch ADPWS-502
Volume Range:2 to 20µl
Increment:0.5µl
Test Volume:20µl <br/> 10µl <br/> 2µl

Fixed Volume Pipette

Fixed Volume Pipette ADFPT-502
Volume:10µl
Accuracy:±4.80µl
Precision:≤2.50µl
Fixed Volume Pipette ADFPT-505
Volume:50µl
Accuracy:±3.00µl
Precision:≤1.50µl
Fixed Volume Pipette ADFPT-506
Volume:100µl
Accuracy:±2.00µl
Precision:≤1.00µl
Fixed Volume Pipette ADFPT-503
Volume:20µl
Accuracy:±3.00µl
Precision:≤1.50µl
Fixed Volume Pipette ADFPT-504
Volume:25µl
Accuracy:±3.00µl
Precision:≤1.50µl
Fixed Volume Pipette ADFPT-501
Volume:5µl
Accuracy:±8.00µl
Precision:≤5.00µl