Multi-Channel Pipette ADMCP-511

Multi-Channel Pipette ADMCP-511

Multi-Channel Pipette ADMCP-511 comes with a volume range of 10 to 100 µl for handling very small liquid capacity with high precision. It is compatible with standard universal tips, allowing for cost-effective operation. This unit allows for uniform sample processing, making it ideal for time-sensitive assays. The smooth operation and reliable sealing enhance reproducibility across repeated tasks. Our Multi-Channel Pipette is used in life sciences and clinical fields for microplate filling and high-throughput screening. 

USD 350.00
Volume Range 10 to 100 µl
Increment 1 µl
Test Volume 100 µl
50 µl
2 µl
Accuracy 0.80 % at 100 µl
1.00 % at 100 µl
3.00 % at 100 µl
Precision 0.15 % at 100 µl
0.40 % at 100 µl
1.50 % at 100 µl
Channel 12
Gross Weight 17 Kg
Dimensions (L×B×H) 0.56×0.36×0.28 m³
  • Volume lock mechanism
  • Autoclavable components
  • Easy tip ejection
  • Ergonomic design
  • User-friendly

Our Multi-Channel Pipette ADMCP-511 is used in clinical diagnostics for immunoassays, pharmaceutical research for high-throughput screening and biotechnology for protein analysis.

Frequently Asked Questions of Multi-Channel Pipette ADMCP-511

1. What are the advantages of using a Multi-channel pipette in a lab?

Multi-channel pipette drastically improve productivity by enabling fast and accurate pipetting across multiple samples. It reduces hand fatigue and the risk of repetitive strain injuries during large-scale experiments. This pipette ensure uniform sample volumes across wells, enhancing experimental reliability. It is ideal for plate-based assays like microplate readings, where uniformity is critical. Overall, it streamline workflows in high-throughput environments.

2. What is a Multi-Channel Pipette and how does it differ from a Single-Channel Pipette?

A Multi-Channel Pipette is a laboratory instrument that allows simultaneous dispensing or aspiration of liquids using multiple channels, typically 8 or 12. Unlike a Single-Channel Pipette, which handles one sample at a time, Multi-Channel Pipette increase throughput by working with multiple wells simultaneously, such as in a 96-well plate. It is commonly used in ELISA, PCR, and high-throughput screening.

3. How to calibrate a Multi-Channel Pipette?

Calibration of a Multi-Channel Pipette involves checking each channel for volume accuracy and precision using gravimetric or photometric methods. Each channel must be tested individually to ensure consistent performance across all tips. If deviations are found, adjustments are made following the manufacturer’s guidelines. Calibration should be performed regularly, especially in GLP-compliant labs.

4. What are common errors while using a Multi-Channel Pipette and how to avoid them?

Common errors include uneven tip loading, misalignment with well plates, and applying inconsistent pipetting force. To avoid these, ensure tips are firmly and evenly attached, use proper pipetting techniques, and practice consistent vertical positioning over wells. Also, pre-wet the tips to reduce volume inconsistencies. Avoid tilting the pipette while aspirating or dispensing to maintain accuracy.

5. What types of lab applications commonly use Multi-Channel Pipette?

Multi-Channel Pipette is widely used in applications like ELISA, qPCR, cell culture, drug screening, and DNA/RNA extraction. These tasks often involve 96- or 384-well microplates, where processing multiple samples quickly and uniformly is essential. The pipette speeds up repetitive liquid handling while maintaining precision. This makes it indispensable in research, clinical diagnostics, and pharmaceutical labs.

Similar Products of Multi-Channel Pipette

Volume Range 0.5 to 10 µl
Increment 0.1 µl
Test Volume 10 µl
5 µl
1 µl

USD 350.00

Volume Range 50 to 300 µl
Increment 5 µl
Test Volume 300 µl
150 µl
50 µl

USD 340.00

Volume Range 10 to 100 µl
Increment 1 µl
Test Volume 100 µl
50 µl
10 µl

USD 340.00

Volume Range 20 to 200 µl
Increment 1 µl
Test Volume 200 µl
100 µl
20 µl

USD 340.00

Electronic Pipette

Electronic Pipette ADEP-504
Volume Range:50-1000µl
Increment:1.00µl
Test Volume:100µl<br/> 500µl<br/> 1000µl

USD 700.00

Electronic Pipette ADEP-503
Volume Range:10 to 300µl
Increment:0.20µl
Test Volume:30µl<br>150µl<br>300µl

USD 700.00

Electronic Pipette ADEP-506
Volume Range:500 to 10000 µl
Increment:10.00 µl
Test Volume:10000 µl <br/> 5000 µl <br/> 1000 µl

USD 700.00

Electronic Pipette ADEP-505
Volume Range:100to5000µl
Increment:5.00µl
Test Volume:5000µl<br/> 2500µl<br/> 500µl

USD 630.00

Electronic Pipette ADEP-501
Volume Range:0.1 to 10 µl
Increment:0.01 µl
Test Volume:10 µl <br/> 5 µl <br/> 1 µl

USD 700.00

Electronic Pipette ADEP-502
Volume Range:5 to 120µl
Increment:0.10 µl
Test Volume:12 µl<br/> 60 µl<br/> 120 µl

USD 700.00

Mini Fixed Volume Pipette

Mini Fixed Volume Pipette ADFVP-505
Volume Range:50µl
Accuracy:±1% at 50µl
Precision:±0.4% at 50µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-507
Volume Range:100µl
Accuracy:±0.8% at 100µl
Precision:±0.3% at 100µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-509
Volume Range:300µl
Accuracy:±0.8% at 300µl
Precision:±0.3% at 300µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-503
Volume Range:20µl
Accuracy:±1.0% at 20µl
Precision:±0.5% at 20µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-506
Volume Range:75µl
Accuracy:±0.8% at 75µl
Precision :±0.3% at 75µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-501
Volume Range:5µl
Accuracy:±2.5% at 5µl
Precision :±1.5% at 5µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-508
Volume Range:200µl
Accuracy:±0.8% at 200µl
Precision:±0.3% at 200µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-502
Volume Range:10µl
Accuracy:±1.2% at 10µl
Precision:±0.8% at 10µl

USD 310.00

Mini Fixed Volume Pipette ADFVP-504
Volume Range:30µl
Accuracy:±1.0% at 30µl
Precision :±0.4% at 30µl

USD 310.00

Single Channel Variable Pipette

Single Channel Variable Pipette ADCVP-514
Volume Range:10 to 100 µl
Increment:0.2 µl
Test Volume:10 µl<br/> 50 µl<br/> 100 µl

USD 510.00

Single Channel Variable Pipette ADCVP-515
Volume Range:20 to 200 µl
Increment:0.2 µl
Test Volume:20 µl<br/> 100 µl<br/> 200 µl

USD 510.00

Single Channel Variable Pipette ADCVP-512
Volume Range:0.5 to 10 µl
Increment:0.02 µl
Test Volume:1 µl<br/> 5µl<br/> 10 µl

USD 510.00

Single Channel Variable Pipette ADCVP-517
Volume Range:0.5 to 5 µl
Increment:20 µl
Test Volume:1000 µl<br/> 2500 µl<br/> 5000 µl

USD 510.00

Single Channel Variable Pipette ADCVP-505
Volume Range:10 to 100 µl
Increment:1 µl
Test Volume:100 µl<br/> 50 µl<br/> 10 µl

USD 310.00

Single Channel Variable Pipette ADCVP-509
Volume Range:1 to 5 µl
Increment:0.05 µl
Test Volume:5 µl<br/> 2.5µl<br/> 1 µl

USD 310.00

Single Channel Variable Pipette ADCVP-518
Volume Range:1 to 10 µl
Increment:20 µl
Test Volume:1 µl<br/> 5µl<br/> 10 µl

USD 510.00

Single Channel Variable Pipette ADCVP-513
Volume Range:2 to 20 µl
Increment:0.02 µl
Test Volume:2 µl<br/> 10 µl<br/> 20 µl

USD 510.00

Single Channel Variable Pipette ADCVP-516
Volume Range:100 to 1000 µl
Increment:2 µl
Test Volume:100µl<br/> 500µl<br/> 1000 µl

USD 510.00

Single Channel Variable Pipette ADCVP-506
Volume Range:20 to 200 µl
Increment:1 µl
Test Volume:200µl<br/> 100µl<br/> 20 µl

USD 310.00

Single Channel Variable Pipette ADCVP-503
Volume Range:2to 20 µl
Increment:0.5 µl
Test Volume:20 µl<br/> 10 µl<br/> 2 µl

USD 310.00

Single Channel Variable Pipette ADCVP-502
Volume Range:0.5 to 10 µl
Increment:0.1 µl
Test Volume:1 µl<br/> 5µl<br/> 1 µl

USD 310.00

Single Channel Variable Pipette ADCVP-504
Volume Range:5 to 50 µl
Increment:0.5 µl
Test Volume:50 µl<br/> 25 µl<br/> 5 µl

USD 310.00

Single Channel Variable Pipette ADCVP-510
Volume Range:1 to 10 µl
Increment:0.1 µl
Test Volume:10 µl<br/> 5µl<br/> 1 µl

USD 310.00

Single Channel Variable Pipette ADCVP-508
Volume Range:100 to 1000 µl
Increment:5 µl
Test Volume:1000 µl<br/> 500µl<br/> 100 µl

USD 310.00

Single Channel Variable Pipette ADCVP-507
Volume Range:30to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 30 µl

USD 310.00

Single Channel Variable Pipette ADCVP-511
Volume Range:0.2 to 2 µl
Increment:0.002 µl
Test Volume:0.2 µl<br/> 0.5µl<br/> 2 µl

USD 510.00

Single Channel Variable Pipette ADCVP-501
Volume Range:0.1 to 2.5 µl
Increment:0.05 µl
Test Volume:0.25 µl<br/> 1.25 µl<br/> 2.5 µl

USD 310.00

Pipette With Switch

Pipette With Switch ADPWS-505
Volume Range:20 to 200µl
Increment:1µl
Test Volume:200µl <br/> 100µl <br/> 20µl

USD 590.00

Pipette With Switch ADPWS-504
Volume Range:10 to 100µl
Increment:1µl
Test Volume:100µl <br/> 50µl <br/> 10µl

USD 590.00

Pipette With Switch ADPWS-506
Volume Range:10 to 1000µl
Increment:5µl
Test Volume:1000µl <br/> 500µl <br/> 100µl

USD 590.00

Pipette With Switch ADPWS-503
Volume Range:5 to 50µl
Increment:0.5µl
Test Volume:50µl <br/> 25µl <br/> 5µl

USD 590.00

Pipette With Switch ADPWS-501
Volume Range:0.5 to 10µl
Increment:0.1µl
Test Volume:10µl <br/> 5µl <br/> 1µl

USD 590.00

Pipette With Switch ADPWS-507
Volume Range:1 to 5µl
Increment:50µl
Test Volume:5000µl <br/> 2500µl <br/> 1000µl

USD 590.00

Pipette With Switch ADPWS-502
Volume Range:2 to 20µl
Increment:0.5µl
Test Volume:20µl <br/> 10µl <br/> 2µl

USD 590.00

Fixed Volume Pipette

Fixed Volume Pipette ADFPT-503
Volume:20µl
Accuracy:±3.00µl
Precision:≤1.50µl

USD 240.00

Fixed Volume Pipette ADFPT-505
Volume:50µl
Accuracy:±3.00µl
Precision:≤1.50µl

USD 240.00

Fixed Volume Pipette ADFPT-504
Volume:25µl
Accuracy:±3.00µl
Precision:≤1.50µl

USD 240.00

Fixed Volume Pipette ADFPT-506
Volume:100µl
Accuracy:±2.00µl
Precision:≤1.00µl

USD 240.00

Fixed Volume Pipette ADFPT-502
Volume:10µl
Accuracy:±4.80µl
Precision:≤2.50µl

USD 240.00

Fixed Volume Pipette ADFPT-501
Volume:5µl
Accuracy:±8.00µl
Precision:≤5.00µl

USD 240.00