Multi-Channel Pipette ADMCP-511 comes with a volume range of 10 to 100 µl for handling very small liquid capacity with high precision. It is compatible with standard universal tips, allowing for cost-effective operation. This unit allows for uniform sample processing, making it ideal for time-sensitive assays. The smooth operation and reliable sealing enhance reproducibility across repeated tasks. Our Multi-Channel Pipette is used in life sciences and clinical fields for microplate filling and high-throughput screening.
Volume Range | 10 to 100 µl |
Increment | 1 µl |
Test Volume |
100 µl 50 µl 2 µl |
Accuracy |
0.80 % at 100 µl 1.00 % at 100 µl 3.00 % at 100 µl |
Precision |
0.15 % at 100 µl 0.40 % at 100 µl 1.50 % at 100 µl |
Channel | 12 |
Gross Weight | 17 Kg |
Dimensions (L×B×H) | 0.56×0.36×0.28 m³ |
Our Multi-Channel Pipette ADMCP-511 is used in clinical diagnostics for immunoassays, pharmaceutical research for high-throughput screening and biotechnology for protein analysis.
1. What are the advantages of using a Multi-channel pipette in a lab?
Multi-channel pipette drastically improve productivity by enabling fast and accurate pipetting across multiple samples. It reduces hand fatigue and the risk of repetitive strain injuries during large-scale experiments. This pipette ensure uniform sample volumes across wells, enhancing experimental reliability. It is ideal for plate-based assays like microplate readings, where uniformity is critical. Overall, it streamline workflows in high-throughput environments.
2. What is a Multi-Channel Pipette and how does it differ from a Single-Channel Pipette?
A Multi-Channel Pipette is a laboratory instrument that allows simultaneous dispensing or aspiration of liquids using multiple channels, typically 8 or 12. Unlike a Single-Channel Pipette, which handles one sample at a time, Multi-Channel Pipette increase throughput by working with multiple wells simultaneously, such as in a 96-well plate. It is commonly used in ELISA, PCR, and high-throughput screening.
3. How to calibrate a Multi-Channel Pipette?
Calibration of a Multi-Channel Pipette involves checking each channel for volume accuracy and precision using gravimetric or photometric methods. Each channel must be tested individually to ensure consistent performance across all tips. If deviations are found, adjustments are made following the manufacturer’s guidelines. Calibration should be performed regularly, especially in GLP-compliant labs.
4. What are common errors while using a Multi-Channel Pipette and how to avoid them?
Common errors include uneven tip loading, misalignment with well plates, and applying inconsistent pipetting force. To avoid these, ensure tips are firmly and evenly attached, use proper pipetting techniques, and practice consistent vertical positioning over wells. Also, pre-wet the tips to reduce volume inconsistencies. Avoid tilting the pipette while aspirating or dispensing to maintain accuracy.
5. What types of lab applications commonly use Multi-Channel Pipette?
Multi-Channel Pipette is widely used in applications like ELISA, qPCR, cell culture, drug screening, and DNA/RNA extraction. These tasks often involve 96- or 384-well microplates, where processing multiple samples quickly and uniformly is essential. The pipette speeds up repetitive liquid handling while maintaining precision. This makes it indispensable in research, clinical diagnostics, and pharmaceutical labs.
Volume Range | 0.5 to 10 µl |
Increment | 0.1 µl |
Test Volume |
10 µl 5 µl 1 µl |
USD 350.00
Volume Range | 50 to 300 µl |
Increment | 5 µl |
Test Volume |
300 µl 150 µl 50 µl |
USD 340.00
Volume Range | 10 to 100 µl |
Increment | 1 µl |
Test Volume |
100 µl 50 µl 10 µl |
USD 340.00
Volume Range | 20 to 200 µl |
Increment | 1 µl |
Test Volume |
200 µl 100 µl 20 µl |
USD 340.00
Volume Range: | 50-1000µl |
Increment: | 1.00µl |
Test Volume: | 100µl<br/> 500µl<br/> 1000µl |
USD 700.00
Volume Range: | 10 to 300µl |
Increment: | 0.20µl |
Test Volume: | 30µl<br>150µl<br>300µl |
USD 700.00
Volume Range: | 500 to 10000 µl |
Increment: | 10.00 µl |
Test Volume: | 10000 µl <br/> 5000 µl <br/> 1000 µl |
USD 700.00
Volume Range: | 100to5000µl |
Increment: | 5.00µl |
Test Volume: | 5000µl<br/> 2500µl<br/> 500µl |
USD 630.00
Volume Range: | 0.1 to 10 µl |
Increment: | 0.01 µl |
Test Volume: | 10 µl <br/> 5 µl <br/> 1 µl |
USD 700.00
Volume Range: | 5 to 120µl |
Increment: | 0.10 µl |
Test Volume: | 12 µl<br/> 60 µl<br/> 120 µl |
USD 700.00
Volume Range: | 50µl |
Accuracy: | ±1% at 50µl |
Precision: | ±0.4% at 50µl |
USD 310.00
Volume Range: | 100µl |
Accuracy: | ±0.8% at 100µl |
Precision: | ±0.3% at 100µl |
USD 310.00
Volume Range: | 300µl |
Accuracy: | ±0.8% at 300µl |
Precision: | ±0.3% at 300µl |
USD 310.00
Volume Range: | 20µl |
Accuracy: | ±1.0% at 20µl |
Precision: | ±0.5% at 20µl |
USD 310.00
Volume Range: | 75µl |
Accuracy: | ±0.8% at 75µl |
Precision : | ±0.3% at 75µl |
USD 310.00
Volume Range: | 5µl |
Accuracy: | ±2.5% at 5µl |
Precision : | ±1.5% at 5µl |
USD 310.00
Volume Range: | 200µl |
Accuracy: | ±0.8% at 200µl |
Precision: | ±0.3% at 200µl |
USD 310.00
Volume Range: | 10µl |
Accuracy: | ±1.2% at 10µl |
Precision: | ±0.8% at 10µl |
USD 310.00
Volume Range: | 30µl |
Accuracy: | ±1.0% at 30µl |
Precision : | ±0.4% at 30µl |
USD 310.00
Volume Range: | 10 to 100 µl |
Increment: | 0.2 µl |
Test Volume: | 10 µl<br/> 50 µl<br/> 100 µl |
USD 510.00
Volume Range: | 20 to 200 µl |
Increment: | 0.2 µl |
Test Volume: | 20 µl<br/> 100 µl<br/> 200 µl |
USD 510.00
Volume Range: | 0.5 to 10 µl |
Increment: | 0.02 µl |
Test Volume: | 1 µl<br/> 5µl<br/> 10 µl |
USD 510.00
Volume Range: | 0.5 to 5 µl |
Increment: | 20 µl |
Test Volume: | 1000 µl<br/> 2500 µl<br/> 5000 µl |
USD 510.00
Volume Range: | 10 to 100 µl |
Increment: | 1 µl |
Test Volume: | 100 µl<br/> 50 µl<br/> 10 µl |
USD 310.00
Volume Range: | 1 to 5 µl |
Increment: | 0.05 µl |
Test Volume: | 5 µl<br/> 2.5µl<br/> 1 µl |
USD 310.00
Volume Range: | 1 to 10 µl |
Increment: | 20 µl |
Test Volume: | 1 µl<br/> 5µl<br/> 10 µl |
USD 510.00
Volume Range: | 2 to 20 µl |
Increment: | 0.02 µl |
Test Volume: | 2 µl<br/> 10 µl<br/> 20 µl |
USD 510.00
Volume Range: | 100 to 1000 µl |
Increment: | 2 µl |
Test Volume: | 100µl<br/> 500µl<br/> 1000 µl |
USD 510.00
Volume Range: | 20 to 200 µl |
Increment: | 1 µl |
Test Volume: | 200µl<br/> 100µl<br/> 20 µl |
USD 310.00
Volume Range: | 2to 20 µl |
Increment: | 0.5 µl |
Test Volume: | 20 µl<br/> 10 µl<br/> 2 µl |
USD 310.00
Volume Range: | 0.5 to 10 µl |
Increment: | 0.1 µl |
Test Volume: | 1 µl<br/> 5µl<br/> 1 µl |
USD 310.00
Volume Range: | 5 to 50 µl |
Increment: | 0.5 µl |
Test Volume: | 50 µl<br/> 25 µl<br/> 5 µl |
USD 310.00
Volume Range: | 1 to 10 µl |
Increment: | 0.1 µl |
Test Volume: | 10 µl<br/> 5µl<br/> 1 µl |
USD 310.00
Volume Range: | 100 to 1000 µl |
Increment: | 5 µl |
Test Volume: | 1000 µl<br/> 500µl<br/> 100 µl |
USD 310.00
Volume Range: | 30to 300 µl |
Increment: | 5 µl |
Test Volume: | 300 µl<br/> 150 µl<br/> 30 µl |
USD 310.00
Volume Range: | 0.2 to 2 µl |
Increment: | 0.002 µl |
Test Volume: | 0.2 µl<br/> 0.5µl<br/> 2 µl |
USD 510.00
Volume Range: | 0.1 to 2.5 µl |
Increment: | 0.05 µl |
Test Volume: | 0.25 µl<br/> 1.25 µl<br/> 2.5 µl |
USD 310.00
Volume Range: | 20 to 200µl |
Increment: | 1µl |
Test Volume: | 200µl <br/> 100µl <br/> 20µl |
USD 590.00
Volume Range: | 10 to 100µl |
Increment: | 1µl |
Test Volume: | 100µl <br/> 50µl <br/> 10µl |
USD 590.00
Volume Range: | 10 to 1000µl |
Increment: | 5µl |
Test Volume: | 1000µl <br/> 500µl <br/> 100µl |
USD 590.00
Volume Range: | 5 to 50µl |
Increment: | 0.5µl |
Test Volume: | 50µl <br/> 25µl <br/> 5µl |
USD 590.00
Volume Range: | 0.5 to 10µl |
Increment: | 0.1µl |
Test Volume: | 10µl <br/> 5µl <br/> 1µl |
USD 590.00
Volume Range: | 1 to 5µl |
Increment: | 50µl |
Test Volume: | 5000µl <br/> 2500µl <br/> 1000µl |
USD 590.00
Volume Range: | 2 to 20µl |
Increment: | 0.5µl |
Test Volume: | 20µl <br/> 10µl <br/> 2µl |
USD 590.00