| Capacity | 5L |
| Frequency | 50 to 60 Hz |
| Speed Range | 50 to 1800 rpm |
| Time Range | 0-99 hr,59 min |
| Speed Display | LCD |
| Adjust Mode | Knob |
| Motor Type | Brushless |
| Motor Power | 5 W |
| Shell Material | Stainless steel |
| Working Plate Material | Stainless steel |
| Ambient Temperature | 5 to 35℃ |
| Ambient Humidity | 80 % |
| Exterior Dimension(L×B×H) | 204 × 118 × 75 mm |
| Packing Dimension(L×B×H) | 320× 275 × 180 mm |
| Net Weight | 1.6kg |
| Gross Weight | 2 kg |
Our Mini Magnetic Stirrer facilitates precise sample dilution for analytical experiments without the risk of contamination. Its consistent agitation enhances quality and ensures reproducible data integrity.
1. What is the speed range of the Mini Magnetic Stirrer ADHMA-502?
This Mini Magnetic Stirrer ADHMA-502 offers a speed range of 50 to 1800 rpm, suitable for various laboratory mixing tasks. It allows smooth speed control for both low and high agitation needs. This wide range ensures flexibility for different sample types. The adjustable stirring speed enhances precision in lab operations.
2. Can the Mini Magnetic Stirrer ADHMA-502 be used in humid environments?
Yes, Our Mini Magnetic Stirrer ADHMA-502 is designed to operate efficiently in ambient humidity levels of up to 80%. Its sealed construction protects internal components from moisture-related issues. This makes it reliable for use in laboratories with higher humidity levels in environment.
3. Does the Mini Magnetic Stirrer ADHMA-502 support wide voltage input?
This Mini Magnetic Stirrer ADHMA-502 is compatible with a wide voltage range from 100 to 240V, enabling stable performance in various regions. It automatically adjusts to voltage fluctuations, preventing interruptions or damage. This makes it suitable for international laboratories and environments with unstable power supply.
4. Is the Mini Magnetic Stirrer ADHMA-502 easy to move and store?
Yes, Our Mini Magnetic Stirrer ADHMA-502 features a compact and lightweight structure, making it easy to carry and relocate within lab spaces. Its space-saving design is ideal for benchtops with limited area. The unit can be stored conveniently when not in use. Despite its small size, it maintains strong stirring power and stability.
5. What type of user interface does the Mini Magnetic Stirrer ADHMA-502 offer?
This Mini Magnetic Stirrer ADHMA-502 comes with a touch control interface that provides smooth and precise operation. Users can easily adjust the stirring speed with a simple touch. The interface is easy to clean and reduces the risk of contamination. Unlike mechanical buttons, it is more durable and user-friendly.
6. How does the Mini Magnetic Stirrer ensure precise speed control for delicate sample mixing?
The Mini Magnetic Stirrer features digitally adjustable speed control that allows users to set exact stirring speeds. This precision prevents damage to delicate samples by providing smooth and uniform mixing. Its gradual ramp-up function avoids sudden jolts, ensuring consistent agitation. These features make the Mini Magnetic Stirrer ideal for sensitive biological and chemical samples.
7. What advanced safety features are integrated into the Mini Magnetic Stirrer for laboratory?
The Mini Magnetic Stirrer includes overheat protection and automatic shut-off to safeguard users during extended use. An anti-corrosion coating protects against chemical spills, enhancing device durability. Its compact design reduces vibration and noise, creating a safer and quieter lab environment. These safety features make the Mini Magnetic Stirrer a dependable tool for rigorous laboratory applications.
8. In what ways does the Mini Magnetic Stirrer improve workflow efficiency in research laboratories?
The Mini Magnetic Stirrer offers rapid start-up and stable agitation, cutting down sample preparation time. Its quiet motor supports continuous operation without disturbing other lab activities. The lightweight and compact design allows easy relocation between workstations. Low maintenance requirements due to its robust build enhance lab productivity. Overall, the researchers focus more on experiments and less on equipment.
| Capacity | 10L |
| Speed Range | 50 to 1800 rpm |
| Frequency | 50 to 60 Hz |
| Capacity | 5L |
| Speed Range | 50 to 1800 rpm |
| Frequency | 50 to 60 Hz |
| Capacity | 10L |
| Frequency | 50 to 60 Hz |
| Time Range | 0 to 99 hr 59 min |
| Capacity | 20 L |
| Frequency | 50 to 60 Hz |
| Speed Range | 100 to 1600 rpm |
| Max capacity: | 20 Liters |
| Temperature control: | RT + 5℃ to 350℃ |
| Over temperature protection: | ≤420 |
| Temperature Setting Range: | 0℃ to 350℃ |
| Temperature Control Range: | RT.+5℃ to 350℃ |
| Timing Range: | 1min to 99h59min /infinite |
| Work Plate Dimension: | 254 x 254 mm (10 inch) |
| Work Plate Material: | Glass ceramic |
| Max. Stirring Quantity: | 30L |
| Max capacity: | 10 Liters |
| Temperature control: | RT + 5℃ to 160℃ |
| Noise dB: | ≤27 |
| Temperature: | R.T. +5°C to 340°C |
| Temperature Calibration Range: | 0°C to 340°C |
| Speed Range: | 100 to 1500 rpm |
| Max capacity: | 3 Liters |
| Temperature control: | RT + 5℃ to 200℃ |
| Temperature control accuracy: | ±1℃ |
| Max capacity: | 20 Liters |
| Temperature control: | RT + 5℃ to 400℃ |
| Over temperature protection: | ≤450 |
| Max capacity: | 20 Liters |
| Temperature control: | RT + 5℃ to 400℃ |
| Temperature control accuracy: | ±1℃ |
| Max capacity: | 20 Liters |
| Temperature control: | RT + 5℃ to 350℃ |
| Temperature control accuracy: | ±1℃ |
| Capacity: | 120 L |
| Frequency: | 50 to 60 Hz |
| Speed Range : | 100 to 1200 rpm |
| Capacity: | 40 L |
| Frequency: | 50 to 60 Hz |
| Speed Range : | 100 to 1600 rpm |
| Capacity: | 150 L |
| Frequency: | 50 to 60 Hz |
| Speed Range : | 100 to 1200 rpm |
| Capacity: | 80 L |
| Frequency: | 50 to 60 Hz |
| Speed Range : | 100 to 1600 rpm |
| Mixing Capacity: | 1000×4 ml |
| Frequency: | 50 to 60 Hz |
| Noise db: | ≤27 |
| Mixing Capacity: | 1000×4 ml |
| Frequency: | 50 to 60 Hz |
| Noise db: | ≤27 |
| Mixing Capacity: | 1000×6 ml |
| Frequency: | 50 to 60 Hz |
| Noise db: | ≤27 |
| Mixing Capacity: | 1000×8 ml |
| Frequency: | 50 to 60 Hz |
| Noise db: | ≤27 |
| Mixing Capacity: | 1000×8 ml |
| Frequency: | 50 to 60 Hz |
| Noise db: | ≤27 |
| Mixing Capacity: | 1000×12 ml |
| Frequency: | 50 to 60 Hz |
| Noise db: | ≤27 |
| Mixing Capacity: | 1000×6 ml |
| Frequency: | 50 to 60 Hz |
| Noise db: | ≤27 |
| Mixing Capacity: | 1000×2 ml |
| Frequency: | 50 to 60 Hz |
| Noise db: | ≤27 |
| Mixing Capacity: | 10 liters |
| Temperature control: | RT + 5℃ to 160℃ |
| Temperature control accuracy: | ±1℃ |
| Mixing Capacity: | 10 liters |
| Temperature control: | RT + 5℃ to 160℃ |
| Temperature control accuracy: | ±1℃ |
| Mixing Capacity: | 10 liters |
| Temperature control: | RT + 5℃ to 160℃ |
| Temperature control accuracy: | ±1℃ |
| Capacity: | 2000 ml x 4 |
| Speed range: | 50-1500rpm |
| Temp of working disc: | RT-310℃ |