| Max capacity | 20 Liters |
| Temperature control | RT + 5℃ to 400℃ |
| Over temperature protection | ≤450 |
| Heating mode | Heating tube |
| Noise dB | ≤27 |
| Shell Material | Outside the steel plate spray |
| Working Plate Material | Aluminum die-cast ceramic coating |
| Speed Range | 0 to 2000 rpm |
| Stirring bars range | 20 to 80 mm |
| Control Mode | Double knob |
| Display mode | Graduated Scale |
| Operation Mode | Continuously |
| Motor type | DC brushless motor |
| Standard bar | C type |
| Ambient Temperature | 5 to 40℃ |
| Ambient Humidity | 80% |
| Working Plate Diameter(L×B×H) | φ 145 mm |
| Instrument Dimension(L×B×H) | 165 × 280 × 105 mm |
| Packing Dimension(L×B×H) | 425 × 390 × 200 mm |
| Heating power | 850 W |
| Whole motor Power | 900 W |
| Output Power | 15 W |
| Power Supply | 220 to 50 V/60 HZ |
| Net Weight | 4 kg |
| Gross Weight | 5.2 kg |
Our Hotplate Magnetic Stirrer ADHMS-507 is commonly used in pharmaceutical industry for preparing cell culture media and drug formulations.
1. What safety features does the Hotplate Magnetic Stirrer ADHMS-509 include?
Hotplate Magnetic Stirrer ADHMS-509 includes an over-heating protection system to prevent damage or accidents caused by excessive temperatures. It also features a hot surface indicator that warns users when the plate is too hot to touch safely. These safety mechanisms ensure reliable operation during prolonged use.
2. What safety features are built into the Hotplate Magnetic Stirrer ADHMS-507?
The Hotplate Magnetic Stirrer ADHMS-507 is equipped with multiple safety features to ensure reliable operation. It includes dual heating circuits, so the system maintains temperature stability even if one circuit fails. Adjustable safe temperature limits help prevent overheating, protecting both the sample and equipment. Additionally, the operation lock function prevents accidental changes during use, enhancing lab safety.
3. Can the Hotplate Magnetic Stirrer ADHMS-507 operate continuously for long durations?
Yes, the Hotplate Magnetic Stirrer ADHMS-507 is built for continuous, long-duration operation without compromising performance. Its durable components and efficient heat management ensure consistent stirring and heating over extended periods. This makes it ideal for time-intensive experiments and overnight procedures in research and industrial labs.
4. What is the stirring speed range of the Hotplate Magnetic Stirrer ADHMS-507?
The Hotplate Magnetic Stirrer ADHMS-507 offers a stirring speed range of 0 to 2000 rpm, allowing precise control based on sample type and application. Speed is easily adjusted using the dedicated control knob, ensuring accurate and consistent mixing. This wide range supports both gentle stirring and vigorous agitation as needed.
5. What type of temperature sensor does Hotplate Magnetic Stirrer ADHMS-507 use?
The Hotplate Magnetic Stirrer ADHMS-507 uses a PT1000 temperature sensor, known for its high accuracy and stability in temperature measurement. This sensor ensures precise control and reliable monitoring, making it suitable for sensitive experiments that require consistent thermal conditions.
6. What is the material of the Hotplate Magnetic Stirrer ADHMS-507 stirring plate?
The Hotplate Magnetic Stirrer ADHMS-507 stirring plate is made of aluminum diecast with a ceramic coating, providing excellent durability, heat resistance, and chemical corrosion protection. This material ensures uniform heat distribution and a long service life, even under demanding lab conditions.
7. What safety features are included with the Hotplate Magnetic Stirrer?
Safety features of Hotplate Magnetic Stirrer typically include overheat protection, temperature limit controls, non-slip feet to prevent the unit from shifting, and a thermal shut-off to protect against overheating. Always ensure to operate the unit according to the instructions and use appropriate safety gear, such as heat-resistant gloves and eye protection.
8. What are the advantages of using a Hotplate Magnetic Stirrer?
The advantages of using a Hotplate Magnetic Stirrer include its ability to heat and stir liquids simultaneously, offering precise temperature control and uniform mixing. It reduces the risk of contamination due to its non-contact stirring mechanism, making it ideal for sensitive applications. The device is compact, energy-efficient, and low-maintenance, with easy-to-use controls and built-in safety features such as overheat protection.
9. Can a Hotplate Magnetic Stirrer be used for precise temperature control?
Yes, our Hotplate Magnetic Stirrers come with built-in temperature control features, including temperature probes for accurate measurement and control of the heating element. This allows for precise temperature regulation, making the device suitable for experiments that require specific thermal conditions, such as enzyme reactions or solvent evaporation. Our Advanced models also feature digital displays and programmable settings for enhanced accuracy and repeatability.
| Temperature Setting Range | 0℃ to 350℃ |
| Temperature Control Range | RT.+5℃ to 350℃ |
| Timing Range | 1min to 99h59min /infinite |
| Temperature | R.T. +5°C to 340°C |
| Temperature Calibration Range | 0°C to 340°C |
| Speed Range | 100 to 1500 rpm |
| Max capacity | 20 Liters |
| Temperature control | RT + 5℃ to 400℃ |
| Temperature control accuracy | ±1℃ |
| Work Plate Dimension | 254 x 254 mm (10 inch) |
| Work Plate Material | Glass ceramic |
| Max. Stirring Quantity | 30L |
| Capacity: | 5L |
| Speed Range : | 50 to 1800 rpm |
| Frequency : | 50 to 60 Hz |
| Capacity: | 10L |
| Frequency: | 50 to 60 Hz |
| Time Range : | 0 to 99 hr 59 min |
| Capacity: | 20 L |
| Frequency: | 50 to 60 Hz |
| Speed Range : | 100 to 1600 rpm |
| Capacity : | 10L |
| Speed Range : | 50 to 1800 rpm |
| Frequency : | 50 to 60 Hz |
| Capacity: | 5L |
| Frequency: | 50 to 60 Hz |
| Speed Range : | 50 to 1800 rpm |
| Capacity: | 120 L |
| Frequency: | 50 to 60 Hz |
| Speed Range : | 100 to 1200 rpm |
| Capacity: | 80 L |
| Frequency: | 50 to 60 Hz |
| Speed Range : | 100 to 1600 rpm |
| Capacity: | 40 L |
| Frequency: | 50 to 60 Hz |
| Speed Range : | 100 to 1600 rpm |
| Capacity: | 150 L |
| Frequency: | 50 to 60 Hz |
| Speed Range : | 100 to 1200 rpm |
| Mixing Capacity: | 1000×6 ml |
| Frequency: | 50 to 60 Hz |
| Noise db: | ≤27 |
| Mixing Capacity: | 1000×4 ml |
| Frequency: | 50 to 60 Hz |
| Noise db: | ≤27 |
| Mixing Capacity: | 1000×4 ml |
| Frequency: | 50 to 60 Hz |
| Noise db: | ≤27 |
| Mixing Capacity: | 1000×8 ml |
| Frequency: | 50 to 60 Hz |
| Noise db: | ≤27 |
| Mixing Capacity: | 1000×6 ml |
| Frequency: | 50 to 60 Hz |
| Noise db: | ≤27 |
| Mixing Capacity: | 1000×2 ml |
| Frequency: | 50 to 60 Hz |
| Noise db: | ≤27 |
| Mixing Capacity: | 1000×8 ml |
| Frequency: | 50 to 60 Hz |
| Noise db: | ≤27 |
| Mixing Capacity: | 1000×12 ml |
| Frequency: | 50 to 60 Hz |
| Noise db: | ≤27 |
| Mixing Capacity: | 10 liters |
| Temperature control: | RT + 5℃ to 160℃ |
| Temperature control accuracy: | ±1℃ |
| Mixing Capacity: | 10 liters |
| Temperature control: | RT + 5℃ to 160℃ |
| Temperature control accuracy: | ±1℃ |
| Capacity: | 2000 ml x 4 |
| Speed range: | 50-1500rpm |
| Temp of working disc: | RT-310℃ |
| Mixing Capacity: | 10 liters |
| Temperature control: | RT + 5℃ to 160℃ |
| Temperature control accuracy: | ±1℃ |