| Mixing Capacity | 1000×6 ml |
| Frequency | 50 to 60 Hz |
| Noise db | ≤27 |
| Display Mode | LCD |
| Mixing Point | 6 |
| Shell Material | 316 Stainless Steel |
| Working Plate Material | 316 Stainless Steel |
| Working Distance | 115mm |
| Speed Range | 200 to 2200 rpm |
| Timing Range | 0-9999 min |
| Protection Level | IP64 |
| Stirrer Range | ≤20 mm |
| Control Mode | Double Knob |
| Operation Mode | Synchronize |
| Drive | Motor Drive |
| Ambient Temperature | 5 to 40℃ |
| Ambient Humidity | 80 % |
| Working Plate Diameter(L×B×H) | 405×240 mm |
| Instrument Dimension(L×B×H) | 465× 240 × 75 mm |
| Packing Dimension(L×B×H) | 600 × 405 × 170 mm |
| Whole Power | 25W |
| Power supply | 100 to 240 V |
| Net Weight | 5.5 kg |
| Gross Weight | 7.2 kg |
Our multi position magnetic stirrer is used in environmental laboratories to simultaneously agitate various samples like water, soil, and air for efficient contaminant analysis over a period of time.
1. How many stirring positions does the Multi Position Magnetic Stirrer ADMMS-502 support?
This Multi Position Magnetic Stirrer ADMMS-502 supports four independent stirring positions. Each position can be controlled separately, allowing multiple samples to be mixed simultaneously at different speeds. This enhances efficiency by enabling parallel sample processing.
2. Does the Multi Position Magnetic Stirrer ADMMS-502 have any indicators to monitor?
Our Multi Position Magnetic Stirrer ADMMS-502 features LED indicators for each position. These lights clearly show whether a position is actively stirring or idle. This helps users monitor multiple samples quickly and reduces errors during experiments. The visual feedback improves overall workflow management. It’s designed for easy supervision in busy labs.
3. Is the Multi Position Magnetic Stirrer ADMMS-502 easy to clean and maintain?
This Multi Position Magnetic Stirrer ADMMS-502 is designed with a corrosion-resistant surface for easy cleaning. Its smooth top plate resists chemical spills and stains, supporting laboratory hygiene. Routine maintenance is simple, helping to ensure long-term durability. The sturdy construction minimizes downtime and repair needs.
4. Can the Multi Position Magnetic Stirrer ADMMS-502 be used for temperature-sensitive?
Our Multi Position Magnetic Stirrer ADMMS-502 primarily focuses on stirring but can be used with external temperature controls. Its precise speed adjustment allows gentle mixing of temperature-sensitive samples without causing damage. When combined with temperature-controlled environments, it ensures safe handling of delicate compounds.
5. What kind of maintenance is required for the Multi Position Magnetic Stirrer ADMMS-502?
This Multi Position Magnetic Stirrer ADMMS-502 requires minimal maintenance thanks to its robust design and corrosion-resistant surface. Regular cleaning of the top plate with a soft cloth is recommended to prevent build-up of residues. Periodic checks of electrical connections and controls ensure safe operation.
6. What is the ideal use of the Multi Position Magnetic Stirrer in laboratory settings?
The Multi Position Magnetic Stirrer is ideal for laboratories that need to mix multiple samples simultaneously. It helps save time by handling several reactions at once. The device ensures consistent stirring for uniform sample preparation. It is especially useful in chemical and pharmaceutical research labs. The Multi Position Magnetic Stirrer supports efficient workflow in busy lab environments.
7. How does the Multi Position Magnetic Stirrer help in improving sample preparation?
The Multi Position Magnetic Stirrer provides even and consistent agitation across all positions. This uniform stirring results in reliable and reproducible sample preparation. The device minimizes human error by automating the mixing process. It supports a wide range of sample volumes and vessel types. The Multi Position Magnetic Stirrer enhances the quality and accuracy of experimental results.
8. Is the Multi Position Magnetic Stirrer suitable for limited bench space?
The Multi Position Magnetic Stirrer has a compact footprint designed to save valuable bench space. It allows placement of multiple samples without overcrowding the workspace. The lightweight design makes it easy to move and reposition as needed. Despite its small size, it offers stable and efficient stirring performance. The Multi Position Magnetic Stirrer is a practical solution for labs with space constraints.
| Mixing Capacity | 1000×8 ml |
| Frequency | 50 to 60 Hz |
| Noise db | ≤27 |
| Mixing Capacity | 1000×6 ml |
| Frequency | 50 to 60 Hz |
| Noise db | ≤27 |
| Mixing Capacity | 1000×4 ml |
| Frequency | 50 to 60 Hz |
| Noise db | ≤27 |
| Mixing Capacity | 1000×4 ml |
| Frequency | 50 to 60 Hz |
| Noise db | ≤27 |
| Temperature: | R.T. +5°C to 340°C |
| Temperature Calibration Range: | 0°C to 340°C |
| Speed Range: | 100 to 1500 rpm |
| Work Plate Dimension: | 254 x 254 mm (10 inch) |
| Work Plate Material: | Glass ceramic |
| Max. Stirring Quantity: | 30L |
| Max capacity: | 20 Liters |
| Temperature control: | RT + 5℃ to 400℃ |
| Temperature control accuracy: | ±1℃ |
| Max capacity: | 10 Liters |
| Temperature control: | RT + 5℃ to 160℃ |
| Noise dB: | ≤27 |
| Max capacity: | 20 Liters |
| Temperature control: | RT + 5℃ to 400℃ |
| Over temperature protection: | ≤450 |
| Temperature Setting Range: | 0℃ to 350℃ |
| Temperature Control Range: | RT.+5℃ to 350℃ |
| Timing Range: | 1min to 99h59min /infinite |
| Max capacity: | 20 Liters |
| Temperature control: | RT + 5℃ to 350℃ |
| Temperature control accuracy: | ±1℃ |
| Max capacity: | 3 Liters |
| Temperature control: | RT + 5℃ to 200℃ |
| Temperature control accuracy: | ±1℃ |
| Max capacity: | 20 Liters |
| Temperature control: | RT + 5℃ to 350℃ |
| Over temperature protection: | ≤420 |
| Capacity: | 5L |
| Frequency: | 50 to 60 Hz |
| Speed Range : | 50 to 1800 rpm |
| Capacity : | 10L |
| Speed Range : | 50 to 1800 rpm |
| Frequency : | 50 to 60 Hz |
| Capacity: | 10L |
| Frequency: | 50 to 60 Hz |
| Time Range : | 0 to 99 hr 59 min |
| Capacity: | 20 L |
| Frequency: | 50 to 60 Hz |
| Speed Range : | 100 to 1600 rpm |
| Capacity: | 5L |
| Speed Range : | 50 to 1800 rpm |
| Frequency : | 50 to 60 Hz |
| Capacity: | 80 L |
| Frequency: | 50 to 60 Hz |
| Speed Range : | 100 to 1600 rpm |
| Capacity: | 150 L |
| Frequency: | 50 to 60 Hz |
| Speed Range : | 100 to 1200 rpm |
| Capacity: | 40 L |
| Frequency: | 50 to 60 Hz |
| Speed Range : | 100 to 1600 rpm |
| Capacity: | 120 L |
| Frequency: | 50 to 60 Hz |
| Speed Range : | 100 to 1200 rpm |
| Capacity: | 2000 ml x 4 |
| Speed range: | 50-1500rpm |
| Temp of working disc: | RT-310℃ |
| Mixing Capacity: | 10 liters |
| Temperature control: | RT + 5℃ to 160℃ |
| Temperature control accuracy: | ±1℃ |
| Mixing Capacity: | 10 liters |
| Temperature control: | RT + 5℃ to 160℃ |
| Temperature control accuracy: | ±1℃ |
| Mixing Capacity: | 10 liters |
| Temperature control: | RT + 5℃ to 160℃ |
| Temperature control accuracy: | ±1℃ |