Multi-Channel Pipette ADMCP-513

Multi-Channel Pipette ADMCP-513

Multi-Channel Pipette ADMCP-513 has an accuracy of ±1.50 % at 300 µl for ensuring precise and reproducible results in laboratory experiments. It offers accurate liquid handling with digital volume adjustment for enhanced reproducibility. This unit includes a user-friendly tip ejector system for quick disposal of used tips. The ergonomic design of this pipette reduces strain during prolonged use. Our Multi-Channel Pipette is used in pharmaceuticals and academic research for accurate liquid handling. 


Volume Range 30 to 300 µl
Increment 5 µl
Test Volume 300 µl
150 µl
30µl
Accuracy 0.70 % at 300 µl
1.00 % at 300 µl
1.50 % at 300 µl
Precision 0.25 % at 300 µl
0.50 % at 300 µl
0.80 % at 300 µl
Channel 12
Gross Weight 18 Kg
Dimensions (L×B×H) 0.56×0.36×0.28 m³
  • Calibration and adjustment
  • Tip ejection system
  • User-friendly
  • Autoclavability 
  • Volume control and accuracy

Our Multi-Channel Pipette ADMCP-513 is used in various fields, including clinical diagnostics, forensic science, and education, for accurate liquid handling and precise measurements. 

Multi-Channel Pipette ADMCP-513|Channel:12|Increment:5 µl
Multi-Channel Pipette ADMCP-513|User-friendly|Tip ejection system

Frequently Asked Questions of Multi-Channel Pipette ADMCP-513

1. What is a Multi-Channel Pipette and where is it commonly used?

A Multi-Channel Pipette is a laboratory instrument designed to simultaneously aspirate and dispense liquids using multiple channels, typically 8 or 12. It is widely used in applications like ELISA, PCR, and high-throughput screening. This tool increases efficiency by allowing simultaneous processing of multiple wells in microplates. It reduces repetitive strain and time spent compared to single-channel pipettes. Multi-Channel Pipette is essential in molecular biology and clinical diagnostics labs.

2. How to ensure accuracy when using a Multi Channel Pipette?

To ensure accuracy, regularly calibrate the pipette and use compatible tips that fit tightly. Pre-wet the tips before use and maintain a consistent pipetting angle. Avoid touching the sidewalls of wells during aspiration or dispensing. Practice smooth and consistent plunger movement. Always inspect the tips for even liquid uptake before dispensing.

3. What are the advantages of using a Multi-Channel Pipette over a Single-Channel Pipette?

Multi-Channel Pipette significantly reduce pipetting time by allowing multiple wells to be filled or emptied at once. It help maintain consistency across samples in microplate formats. It also reduces repetitive strain injuries from excessive hand movements. Using them improves productivity and throughput in high-volume labs. It is ideal for tasks that require uniform sample handling across wells.

4. What types of errors can occur when using a Multi-Channel Pipette, and how can they be prevented?

Errors like uneven liquid aspiration, cross-contamination, and tip leakage can occur. These can be prevented by using high-quality, compatible tips and ensuring all tips are securely attached. Proper technique, such as vertical pipetting and avoiding air bubbles, is critical. Regular maintenance and cleaning also help reduce performance issues. Training users on correct handling techniques can greatly minimize such errors.

5. Can you use a Multi-Channel Pipette for viscous liquids? Why or why not?

While Multi-Channel Pipette can handle viscous liquids, it is not always ideal for this purpose. Viscous samples can cause inconsistent aspiration across channels due to their resistance. If used, pre-wetting the tips and slower aspiration/dispensing speeds are recommended. Positive displacement pipettes are usually better suited for such liquids. Still, careful technique and adjustments can make Multi-Channel Pipette usable with viscous solutions.

Similar Products of Multi-Channel Pipette

Volume Range 50 to 300 µl
Increment 5 µl
Test Volume 300 µl
150 µl
50 µl
Volume Range 5 to 50 µl
Increment 0.5 µl
Test Volume 50 µl
25 µl
5 µl
Volume Range 20 to 200 µl
Increment 1 µl
Test Volume 200 µl
100 µl
20 µl
Volume Range 20 to 200 µl
Increment 1 µl
Test Volume 200 µl
100 µl
10µl

Electronic Pipette

Electronic Pipette ADEP-502
Volume Range:5 to 120µl
Increment:0.10 µl
Test Volume:12 µl<br/> 60 µl<br/> 120 µl
Electronic Pipette ADEP-501
Volume Range:0.1 to 10 µl
Increment:0.01 µl
Test Volume:10 µl <br/> 5 µl <br/> 1 µl
Electronic Pipette ADEP-503
Volume Range:10 to 300µl
Increment:0.20µl
Test Volume:30µl<br>150µl<br>300µl
Electronic Pipette ADEP-506
Volume Range:500 to 10000 µl
Increment:10.00 µl
Test Volume:10000 µl <br/> 5000 µl <br/> 1000 µl
Electronic Pipette ADEP-504
Volume Range:50-1000µl
Increment:1.00µl
Test Volume:100µl<br/> 500µl<br/> 1000µl
Electronic Pipette ADEP-505
Volume Range:100to5000µl
Increment:5.00µl
Test Volume:5000µl<br/> 2500µl<br/> 500µl

Mini Fixed Volume Pipette

Mini Fixed Volume Pipette ADFVP-508
Volume Range:200µl
Accuracy:±0.8% at 200µl
Precision:±0.3% at 200µl
Mini Fixed Volume Pipette ADFVP-506
Volume Range:75µl
Accuracy:±0.8% at 75µl
Precision :±0.3% at 75µl
Mini Fixed Volume Pipette ADFVP-502
Volume Range:10µl
Accuracy:±1.2% at 10µl
Precision:±0.8% at 10µl
Mini Fixed Volume Pipette ADFVP-501
Volume Range:5µl
Accuracy:±2.5% at 5µl
Precision :±1.5% at 5µl
Mini Fixed Volume Pipette ADFVP-504
Volume Range:30µl
Accuracy:±1.0% at 30µl
Precision :±0.4% at 30µl
Mini Fixed Volume Pipette ADFVP-505
Volume Range:50µl
Accuracy:±1% at 50µl
Precision:±0.4% at 50µl
Mini Fixed Volume Pipette ADFVP-509
Volume Range:300µl
Accuracy:±0.8% at 300µl
Precision:±0.3% at 300µl
Mini Fixed Volume Pipette ADFVP-503
Volume Range:20µl
Accuracy:±1.0% at 20µl
Precision:±0.5% at 20µl
Mini Fixed Volume Pipette ADFVP-507
Volume Range:100µl
Accuracy:±0.8% at 100µl
Precision:±0.3% at 100µl

Single Channel Variable Pipette

Single Channel Variable Pipette ADCVP-511
Volume Range:0.2 to 2 µl
Increment:0.002 µl
Test Volume:0.2 µl<br/> 0.5µl<br/> 2 µl
Single Channel Variable Pipette ADCVP-509
Volume Range:1 to 5 µl
Increment:0.05 µl
Test Volume:5 µl<br/> 2.5µl<br/> 1 µl
Single Channel Variable Pipette ADCVP-502
Volume Range:0.5 to 10 µl
Increment:0.1 µl
Test Volume:1 µl<br/> 5µl<br/> 1 µl
Single Channel Variable Pipette ADCVP-504
Volume Range:5 to 50 µl
Increment:0.5 µl
Test Volume:50 µl<br/> 25 µl<br/> 5 µl
Single Channel Variable Pipette ADCVP-506
Volume Range:20 to 200 µl
Increment:1 µl
Test Volume:200µl<br/> 100µl<br/> 20 µl
Single Channel Variable Pipette ADCVP-512
Volume Range:0.5 to 10 µl
Increment:0.02 µl
Test Volume:1 µl<br/> 5µl<br/> 10 µl
Single Channel Variable Pipette ADCVP-510
Volume Range:1 to 10 µl
Increment:0.1 µl
Test Volume:10 µl<br/> 5µl<br/> 1 µl
Single Channel Variable Pipette ADCVP-515
Volume Range:20 to 200 µl
Increment:0.2 µl
Test Volume:20 µl<br/> 100 µl<br/> 200 µl
Single Channel Variable Pipette ADCVP-516
Volume Range:100 to 1000 µl
Increment:2 µl
Test Volume:100µl<br/> 500µl<br/> 1000 µl
Single Channel Variable Pipette ADCVP-517
Volume Range:0.5 to 5 µl
Increment:20 µl
Test Volume:1000 µl<br/> 2500 µl<br/> 5000 µl
Single Channel Variable Pipette ADCVP-503
Volume Range:2to 20 µl
Increment:0.5 µl
Test Volume:20 µl<br/> 10 µl<br/> 2 µl
Single Channel Variable Pipette ADCVP-513
Volume Range:2 to 20 µl
Increment:0.02 µl
Test Volume:2 µl<br/> 10 µl<br/> 20 µl
Single Channel Variable Pipette ADCVP-508
Volume Range:100 to 1000 µl
Increment:5 µl
Test Volume:1000 µl<br/> 500µl<br/> 100 µl
Single Channel Variable Pipette ADCVP-507
Volume Range:30to 300 µl
Increment:5 µl
Test Volume:300 µl<br/> 150 µl<br/> 30 µl
Single Channel Variable Pipette ADCVP-514
Volume Range:10 to 100 µl
Increment:0.2 µl
Test Volume:10 µl<br/> 50 µl<br/> 100 µl
Single Channel Variable Pipette ADCVP-501
Volume Range:0.1 to 2.5 µl
Increment:0.05 µl
Test Volume:0.25 µl<br/> 1.25 µl<br/> 2.5 µl
Single Channel Variable Pipette ADCVP-518
Volume Range:1 to 10 µl
Increment:20 µl
Test Volume:1 µl<br/> 5µl<br/> 10 µl
Single Channel Variable Pipette ADCVP-505
Volume Range:10 to 100 µl
Increment:1 µl
Test Volume:100 µl<br/> 50 µl<br/> 10 µl

Pipette With Switch

Pipette With Switch ADPWS-503
Volume Range:5 to 50µl
Increment:0.5µl
Test Volume:50µl <br/> 25µl <br/> 5µl
Pipette With Switch ADPWS-505
Volume Range:20 to 200µl
Increment:1µl
Test Volume:200µl <br/> 100µl <br/> 20µl
Pipette With Switch ADPWS-502
Volume Range:2 to 20µl
Increment:0.5µl
Test Volume:20µl <br/> 10µl <br/> 2µl
Pipette With Switch ADPWS-506
Volume Range:10 to 1000µl
Increment:5µl
Test Volume:1000µl <br/> 500µl <br/> 100µl
Pipette With Switch ADPWS-504
Volume Range:10 to 100µl
Increment:1µl
Test Volume:100µl <br/> 50µl <br/> 10µl
Pipette With Switch ADPWS-501
Volume Range:0.5 to 10µl
Increment:0.1µl
Test Volume:10µl <br/> 5µl <br/> 1µl
Pipette With Switch ADPWS-507
Volume Range:1 to 5µl
Increment:50µl
Test Volume:5000µl <br/> 2500µl <br/> 1000µl

Fixed Volume Pipette

Fixed Volume Pipette ADFPT-503
Volume:20µl
Accuracy:±3.00µl
Precision:≤1.50µl
Fixed Volume Pipette ADFPT-501
Volume:5µl
Accuracy:±8.00µl
Precision:≤5.00µl
Fixed Volume Pipette ADFPT-506
Volume:100µl
Accuracy:±2.00µl
Precision:≤1.00µl
Fixed Volume Pipette ADFPT-502
Volume:10µl
Accuracy:±4.80µl
Precision:≤2.50µl
Fixed Volume Pipette ADFPT-505
Volume:50µl
Accuracy:±3.00µl
Precision:≤1.50µl
Fixed Volume Pipette ADFPT-504
Volume:25µl
Accuracy:±3.00µl