Portable Dissolved Oxygen Meter ADPOM-503 detects dissolved oxygen levels from 0 to 20 mg/L with 0.05mg/L accuracy. Its wide temperature measuring range enables enhanced versatility for diverse applications. With 0 to 40g/L salinity compensation, this unit ensures accurate assessment for various samples. A multiline LCD display provides clear and easily visible readings. Ideal for use in aquaculture, water treatment plants and agriculture, our Dissolved Oxygen Tester ensures effective measurements and reliable results.
Dissolved Oxygen Measuring Range | 0 to 20mg/L;0 to 200% |
Resolution Ratio | 0.01mg/L;0.1% |
Measurement Accuracy | 0.05mg/L;0.5% |
Temperature Measurement Range | 0 to 100℃/32 to 212℉ |
Operating Temperature Range | 0 to 60℃/32 to 140℉ |
Automatic Temperature Compensation | 0 to 60℃ |
Temperature Resolution | 0.1℃/1℉ |
Temperature Accuracy | 0.2℃ (0 to 60℃) |
Calibration | 1 point/2 point (0% anaerobic / 100% saturated oxygen) |
Salinity Compensation | 0 to 40 g/L |
Atmospheric Pressure Compensation | 700 to 1400 mbar |
Display Screen | 20×30 mm multiline LCD display |
Protection Level | IP65 |
Auto Backlight | 1 minute |
Auto Shut Off | 20 minutes |
Power Supply | 1×1.5V AAA |
Dimensions (L×W×H) | 185×40×48mm |
Weight | 95g |
Portable Dissolved Oxygen Meter ADPOM-503 monitors oxygen levels in water samples from wastewater treatment plants, aquaculture, industries and research laboratories.
Dissolved Oxygen Concentration Measuring Range | 0 to 20 mg/L |
Dissolved Oxygen Concentration Resolution | 0.01 mg/L |
Dissolved Oxygen Concentration Accuracy | ≤±0.30 mg/L |
Dissolved Oxygen Measuring Range | 0 to 20 mg/L |
Saturation Measuring Range | 0 to 200% |
Temperature Measuring Range | 0 to 50℃ |
COD Range: | 0 to 10000 mg/L (Customized) |
Principle: | UV 254 |
Resolution: | 0.01 mg/L |
Absorbance Detection Range: | 0 to 3Abs |
Optical Path Stability: | ≤±0.005Abs/30min |
Absorbance Resolution: | 0.001Abs |
COD Test Method: | Potassium dichromate method<br/> Alkaline potassium permanganate |
COD Measuring Range: | 10 to 15000mg/L<br/> 0.5 to 25mg/L |
COD Test Limit: | 10mg/L<br/> 0.5mg/L |
Indication Error: | ≤±5% |
Repeatability: | 0.03 |
COD Detection Method: | Potassium dichromate method, Potassium permanganate method |
COD Detection Method: | Potassium dichromate method<br/> Potassium permanganate method |
COD Measuring Range: | 10 to 15000 mg/L |
COD Lower Limit of Measurement: | 3 mg/L |
Test Parameter: | Ozone |
Measuring Range: | 0.05 to 2.5mg/L |
Wavelength: | 520 nm |
Test Parameter: | Ammonia nitrogen |
Measuring Range: | 0.01 to 10mg/L |
Wavelength: | 420 nm |
Test Parameter: | Residual Chlorine |
Measuring Range: | 0.05 to 10 mg/L |
Wavelength: | 520 nm |
Test Parameter: | Total Chlorine |
Measuring Range: | 0.05 to 10 mg/L |
Wavelength: | 520 nm |
Test Parameter: | Chlorine dioxide |
Measuring Range: | 0.1 to 5 mg/L |
Wavelength: | 520 nm |
Measuring Range: | 0 to 1000 NTU (Selectable ranges: 0 to 20 NTU, 0 to 200 NTU, 0 to 1000 NTU) |
Accuracy: | ±0.1NTU or ±5%<br/> ±0.3NTU or ±8% |
Repeatability: | ≤±0.1NTU at<10NTU<br/> ≤±1% at ≥10NTU |
TSS Measuring Range: | 0 to 1000mg/L |
TSS Accuracy: | ±0.3mg/L or ±8% |
TSS Repeatability: | <10mg/L: ≤±0.1mg/L <br/> ≥10mg/L: ≤±1% |
TDS Range: | 0 to 9999 ppm |
Conductivity Range: | 0 to 9999 μS/cm |
Temperature Range: | 0 to 80℃ or 32 to 176℃ |
Measuring Range: | 0 to 10% |
Measuring Temperature Range: | 0 to 99℃ |
Resolution: | 0.01%,0.1℃ |
Temperature Control Range: | 45 to 180℃ |
Digestion Temperature: | 45 to 180℃ |
Temperature Control Accuracy: | ±0.1℃ |
Temperature Control Range: | Room temperature to 180℃ |
Digestion Temperature Range: | 50 to 180℃ |
Temperature Control Accuracy: | ±0.1℃ |
pH Measuring Range: | -2 to 16 pH |
pH resolution: | 0.1pH |
pH indication error: | ±0.2% F.S. |
ORP Measuring Range: | -1000mV to 1000mV |
ORP Resolution: | 1 mV |
ORP measurement Accuracy: | ±0.5% F.S. |
pH Measuring Range: | 0 to 14pH |
pH Resolution: | 0.01pH |
pH Measuring Accuracy: | ±0.01pH |
pH Measuring Range: | 0 to 14 pH |
pH Resolution: | 0.041 pH |
pH Indication Error: | ±0.02 pH |