Portable Water Quality Analyzer ADPWA-504 offers a wavelength of 520 nm for accurate measurement of ozone levels. It uses DPD photometric method, providing a precise and reliable detection. This unit measures ozone from 0.05 to 2.5mg/L, accommodating both low and high concentrations. Equipped with an LED light emitting diode, it ensures a long term, stable performance. Ideal for use in water treatment plants and various industries, our Water Quality Analyzer offers real time monitoring and analysis of water quality.
Test Parameter | Ozone |
Measuring Range | 0.05 to 2.5mg/L |
Wavelength | 520 nm |
Principle | DPD photometric method |
Accuracy | <1.0 mg/L, ≤±0.05mg/, ≥1.0 mg/L, ≤±5% |
Light Source | LED light emitting diode |
Battery Life | More than 24 hours (without shutdown) |
Dimension (L×W×H) | 128×70×48 mm |
Weight | 188 g |
Our Portable Water Quality Analyzer optimally measures ozone and offers real time analysis of water samples, enabling accurate monitoring of the water treatment processes. It is extensively used in environmental monitoring, industrial processing, wastewater treatment plants and research laboratories.
Test Parameter | Ammonia nitrogen |
Measuring Range | 0.01 to 10mg/L |
Wavelength | 420 nm |
Test Parameter | Chlorine dioxide |
Measuring Range | 0.1 to 5 mg/L |
Wavelength | 520 nm |
Test Parameter | Total Chlorine |
Measuring Range | 0.05 to 10 mg/L |
Wavelength | 520 nm |
Test Parameter | Residual Chlorine |
Measuring Range | 0.05 to 10 mg/L |
Wavelength | 520 nm |
COD Range: | 0 to 10000 mg/L (Customized) |
Principle: | UV 254 |
Resolution: | 0.01 mg/L |
Indication Error: | ≤±5% |
Repeatability: | 0.03 |
COD Detection Method: | Potassium dichromate method, Potassium permanganate method |
COD Test Method: | Potassium dichromate method<br/> Alkaline potassium permanganate |
COD Measuring Range: | 10 to 15000mg/L<br/> 0.5 to 25mg/L |
COD Test Limit: | 10mg/L<br/> 0.5mg/L |
COD Detection Method: | Potassium dichromate method<br/> Potassium permanganate method |
COD Measuring Range: | 10 to 15000 mg/L |
COD Lower Limit of Measurement: | 3 mg/L |
Absorbance Detection Range: | 0 to 3Abs |
Optical Path Stability: | ≤±0.005Abs/30min |
Absorbance Resolution: | 0.001Abs |
Dissolved Oxygen Measuring Range: | 0 to 20mg/L;0 to 200% |
Resolution Ratio: | 0.01mg/L;0.1% |
Measurement Accuracy: | 0.05mg/L;0.5% |
Dissolved Oxygen Concentration Measuring Range: | 0 to 20 mg/L |
Dissolved Oxygen Concentration Resolution: | 0.01 mg/L |
Dissolved Oxygen Concentration Accuracy: | ≤±0.30 mg/L |
Dissolved Oxygen Measuring Range: | 0 to 20 mg/L |
Saturation Measuring Range: | 0 to 200% |
Temperature Measuring Range: | 0 to 50℃ |
Measuring Range: | 0 to 1000 NTU (Selectable ranges: 0 to 20 NTU, 0 to 200 NTU, 0 to 1000 NTU) |
Accuracy: | ±0.1NTU or ±5%<br/> ±0.3NTU or ±8% |
Repeatability: | ≤±0.1NTU at<10NTU<br/> ≤±1% at ≥10NTU |
TSS Measuring Range: | 0 to 1000mg/L |
TSS Accuracy: | ±0.3mg/L or ±8% |
TSS Repeatability: | <10mg/L: ≤±0.1mg/L <br/> ≥10mg/L: ≤±1% |
TDS Range: | 0 to 9999 ppm |
Conductivity Range: | 0 to 9999 μS/cm |
Temperature Range: | 0 to 80℃ or 32 to 176℃ |
Measuring Range: | 0 to 10% |
Measuring Temperature Range: | 0 to 99℃ |
Resolution: | 0.01%,0.1℃ |
Temperature Control Range: | 45 to 180℃ |
Digestion Temperature: | 45 to 180℃ |
Temperature Control Accuracy: | ±0.1℃ |
Temperature Control Range: | Room temperature to 180℃ |
Digestion Temperature Range: | 50 to 180℃ |
Temperature Control Accuracy: | ±0.1℃ |
pH Measuring Range: | -2 to 16 pH |
pH resolution: | 0.1pH |
pH indication error: | ±0.2% F.S. |
ORP Measuring Range: | -1000mV to 1000mV |
ORP Resolution: | 1 mV |
ORP measurement Accuracy: | ±0.5% F.S. |
pH Measuring Range: | 0 to 14 pH |
pH Resolution: | 0.041 pH |
pH Indication Error: | ±0.02 pH |
pH Measuring Range: | 0 to 14pH |
pH Resolution: | 0.01pH |
pH Measuring Accuracy: | ±0.01pH |