pH Tester ADPH-501
pH Tester ADPH-501-front view
pH Tester ADPH-501-Left side view
pH Tester ADPH-501-Right side view
pH Tester ADPH-501- Slightly Left side view

pH Tester ADPH-501

pH Tester ADPH-501 offers a pH measuring range of -2 to 16 pH with a high resolution of 0.1pH. It also measures ORP over a wide range, making it suitable for various applications. Featuring a digital display, this unit provides clear readings, enhancing user convenience. A battery life of 500 hours ensures an extended and reliable operation. Our pH Tester is versatile and delivers accurate results in chemical, biological, environmental and pharmaceutical research laboratories.

pH Measuring Range -2 to 16 pH
pH resolution 0.1pH
pH indication error ±0.2% F.S.
ORP Measuring Range -2000 to 2000 mV
ORP resolution 1 mV
ORP indication error ±0.2% F.S.
Temperature Measuring Range -10⁰C
Temperature resolution 0.1⁰C
Temperature indication error ±0.2⁰C
Power Supply 4 AAA batteries or transformer 100 to 220V
Battery Life More than 500 hours
First Group Calibration 1.68, 4.00, 6.86, 9.18, 12.46
Second Group Calibration 1.68, 4.00, 7.00, 10.01, 12.46
Operating Temperature -5⁰C to 60⁰C
Operating Humidity Relative humidity <90%
Data Storage 256 sets of measurement
Dimensions (L×B×H) 150×200×60 mm
Weight 650 g
  • Backlit LCD display
  • 5-point calibration
  • Compact design
  • Anti-interference performance
  • Low maintenance

Our pH Meters are used in chemical, biological, environmental, food and pharmaceutical research laboratories to provide accurate and reliable pH readings.

COD Analyzer

COD Analyzer ADCOD-501
COD Range:0 to 10000 mg/L (Customized)
Principle:UV 254
Resolution:0.01 mg/L

Multi Parameter Water Quality Analyzer

Multi Parameter Water Quality Analyzer ADMWA-503
COD Detection Method:Potassium dichromate method<br/> Potassium permanganate method
COD Measuring Range:10 to 15000 mg/L
COD Lower Limit of Measurement:3 mg/L
Multi Parameter Water Quality Analyzer ADMWA-504
Absorbance Detection Range:0 to 3Abs
Optical Path Stability:≤±0.005Abs/30min
Absorbance Resolution:0.001Abs
Multi Parameter Water Quality Analyzer ADMWA-502
COD Test Method:Potassium dichromate method<br/> Alkaline potassium permanganate
COD Measuring Range:10 to 15000mg/L<br/> 0.5 to 25mg/L
COD Test Limit:10mg/L<br/> 0.5mg/L
Multi Parameter Water Quality Analyzer ADMWA-501
Indication Error:≤±5%
Repeatability:0.03
COD Detection Method:Potassium dichromate method, Potassium permanganate method

Portable Dissolved Oxygen Meter

Portable Dissolved Oxygen Meter ADPOM-501
Dissolved Oxygen Concentration Measuring Range:0 to 20 mg/L
Dissolved Oxygen Concentration Resolution:0.01 mg/L
Dissolved Oxygen Concentration Accuracy:≤±0.30 mg/L
Portable Dissolved Oxygen Meter ADPOM-503
Dissolved Oxygen Measuring Range:0 to 20mg/L;0 to 200%
Resolution Ratio:0.01mg/L;0.1%
Measurement Accuracy:0.05mg/L;0.5%
Portable Dissolved Oxygen Meter ADPOM-502
Dissolved Oxygen Measuring Range:0 to 20 mg/L
Saturation Measuring Range:0 to 200%
Temperature Measuring Range:0 to 50℃

Portable Water Quality Analyzer

Portable Water Quality Analyzer ADPWA-504
Test Parameter:Ozone
Measuring Range:0.05 to 2.5mg/L
Wavelength:520 nm
Portable Water Quality Analyzer ADPWA-502
Test Parameter:Total Chlorine
Measuring Range:0.05 to 10 mg/L
Wavelength:520 nm
Portable Water Quality Analyzer ADPWA-503
Test Parameter:Chlorine dioxide
Measuring Range:0.1 to 5 mg/L
Wavelength:520 nm
Portable Water Quality Analyzer ADPWA-501
Test Parameter:Residual Chlorine
Measuring Range:0.05 to 10 mg/L
Wavelength:520 nm
Portable Water Quality Analyzer ADPWA-505
Test Parameter:Ammonia nitrogen
Measuring Range:0.01 to 10mg/L
Wavelength:420 nm

Turbidity Meter

Turbidity Meter ADTM-501
Measuring Range:0 to 1000 NTU (Selectable ranges: 0 to 20 NTU, 0 to 200 NTU, 0 to 1000 NTU)
Accuracy:±0.1NTU or ±5%<br/> ±0.3NTU or ±8%
Repeatability:≤±0.1NTU at<10NTU<br/> ≤±1% at ≥10NTU

TSS Meter

TSS Meter ADTSS-501
TSS Measuring Range:0 to 1000mg/L
TSS Accuracy:±0.3mg/L or ±8%
TSS Repeatability:<10mg/L: ≤±0.1mg/L <br/> ≥10mg/L: ≤±1%

TDS Meter

TDS Meter ADTDS-501
TDS Range:0 to 9999 ppm
Conductivity Range:0 to 9999 μS/cm
Temperature Range:0 to 80℃ or 32 to 176℃

Salinity Tester

Salinity Tester ADSTR-501
Measuring Range:0 to 10%
Measuring Temperature Range:0 to 99℃
Resolution:0.01%,0.1℃

Thermoreactor

Thermoreactor ADTR-501
Temperature Control Range:Room temperature to 180℃
Digestion Temperature Range:50 to 180℃
Temperature Control Accuracy:±0.1℃
Thermoreactor ADTR-502
Temperature Control Range:45 to 180℃
Digestion Temperature:45 to 180℃
Temperature Control Accuracy:±0.1℃

ORP Meter

ORP Meter ADOR-501
ORP Measuring Range:-1000mV to 1000mV
ORP Resolution:1 mV
ORP measurement Accuracy:±0.5% F.S.

PH/ORP Meter

PH/ORP Meter ADPO-501
pH Measuring Range:0 to 14pH
pH Resolution:0.01pH
pH Measuring Accuracy:±0.01pH
PH/ORP Meter ADPO-502
pH Measuring Range:0 to 14 pH
pH Resolution:0.041 pH
pH Indication Error:±0.02 pH