| Temperature Setting Range | 0℃ to 100℃ |
| Temperature Control Range | RT. -20℃ to 100℃ |
| Speed Range | 200 to 1500 rpm |
| Temperature Accuracy | ≤ ± 0.3℃ |
| Temperature Uniformity | ≤ ± 0.3℃ |
| Orbit | 3 mm |
| Heating Time | ≤ 15 min (from 25℃ to 100℃) |
| Cooling Time |
≤ 10min (from 100℃ to 25℃) |
| Timing Range | 1min to 99min59sec / infinite |
| Display Accuracy | 0.1 ℃ |
| Multi-point Running | Maximum 5 points |
| Multi-cycle | Maximum 99 times |
| Auto-heating | Yes |
| Auto-resume | Yes |
| Storage at 4℃ | Yes |
| Power Consumption | AC220V or AC110V, 50/60Hz, 150W |
| Dimension (W × D × H) | 260 × 195 × 150 mm |
| Packing Dimension (W × D × H) | 400 × 300 × 300 mm |
| Net Weight | 7.5 kg |
| Gross Weight | 10 kg |
Thermo-Shaker Incubator ADTSI-504 is ideal for maintaining precise temperatures required for ligation reactions and storing sensitive biological samples. It is also used for field heating, enzyme reactions, deactivation, and PCR preparation.
| Blocks | Description
| Speed Range | Quantity |
| Block 01 | 0.2ml x 96
| 200 to 1500 rpm | 1 Pc |
| Block 02 | 0.5 ml x 54
| 200 to 1500 rpm | 1 Pc |
| Block 03 | 1.5 ml x 35
| 200 to 1500 rpm | 1 Pc |
| Block 04 | 2.0 ml x 35
| 200 to 1500 rpm | 1 Pc |
| Block 05 | 0.5 ml x 15 + 1.5 ml x 20
| 200 to 1800 rpm | 1 Pc |
| Block 06 | 0.2 ml x 96 (ELISA Plate)
| 200 to 1500 rpm | 1 Pc |
| Block 07 | 5 ml x 24
| 200 to 1000 rpm | 1 Pc |
| Block 08 | 10 ml x 15
| 200 to 1000 rpm | 1 Pc |
| Block 09 | 15 ml x 12
| 200 to 800 rpm | 1 Pc |
| Block 10 | Round 50 ml x 6
| 200 to 800 rpm | 1 Pc |
| Block 11 | Conical 50 ml x 6
| 200 to 800 rpm | 1 Pc |
1. What temperature range does the Thermo-Shaker Incubator ADTSI-504 support?
Thermo-Shaker Incubator ADTSI-504 allows temperature settings from 0? up to 100?, providing a wide range suitable for various laboratory processes. This flexibility enables precise control for heating and cooling needs across different applications. It ensures samples are maintained at optimal temperatures for accurate and reliable results.
2. How does the Thermo-Shaker Incubator ADTSI-504 ensure user safety during operation?
Thermo-Shaker Incubator ADTSI-504 includes several safety features. Those are automatic fault detection, a buzzer alarm, and integral over-temperature protection. This system work together to prevent overheating, alert users to potential issues, and maintain safe operation throughout experiments.
3. Is the shaking speed adjustable, and what range does Thermo-Shaker Incubator ADTSI-504 cover?
Thermo-Shaker Incubator ADTSI-504 is fully adjustable, covering a range from 200 to 1500 rpm. This allows users to customize the mixing intensity based on their specific sample requirements. The wide speed range ensures compatibility with different protocols and sample types. It helps achieve optimal mixing and reaction conditions in various laboratory applications.
4. Is maintenance required for the brushless motor in Thermo-Shaker Incubator ADTSI-504?
The brushless motor in the Thermo-Shaker Incubator ADTSI-504 is designed for durability and long service life, requiring minimal maintenance. Unlike traditional motors, it operates quietly and efficiently without the need for regular brush replacements. This reduces downtime and lowers overall maintenance costs. As a result, the unit remains reliable and easy to use for extended periods in busy laboratory environments.
5. Can the Thermo-Shaker Incubator ADTSI-504 resume operation after a power failure?
Thermo-Shaker Incubator ADTSI-504 features an auto-resume function that allows it to continue operation from the last settings after a power failure. This ensures that ongoing experiments are not interrupted or compromised. The unit saves programmed parameters, making recovery seamless and reliable. This feature is especially valuable for long or critical laboratory processes.
6. What is a Thermo-Shaker Incubator used for?
A Thermo-Shaker Incubator is used for simultaneous heating, cooling, and mixing of samples, making it ideal for applications like enzyme reactions, nucleic acid hybridization, cell lysis, and DNA/RNA extraction. It ensures uniform temperature distribution and consistent agitation, improving reaction efficiency and reproducibility. This makes it an essential tool for molecular biology, biochemistry, and clinical laboratories.
7. What are the advantages of using Thermo-Shaker Incubator?
The advantages of using a Thermo-Shaker Incubator include combining precise temperature control with adjustable shaking to ensure uniform mixing and consistent incubation conditions, thereby enhancing reaction efficiency and reproducibility. Its versatile design supports a wide range of sample types through interchangeable blocks, increasing flexibility for various applications.
| Temperature Setting Range | 0℃ to 100℃ |
| Temperature Control Range | RT. +5℃ to 100℃ |
| Speed Range | 200 to 1800 rpm |
| Temperature Control Range | RT +5℃ to 100℃ |
| Speed Range | 300 to 2000 rpm |
| Amplitude | 2 mm, Horizontal rotation |
| Temperature Control Range | RT -20℃ to 100℃ |
| Speed Range | 300 to 1500 rpm |
| Amplitude | 2 mm, Horizontal rotation |
| Capacity: | 2 enzyme standard plates or deep-well plates |
| Speed Range: | 100 to 1600 |
| Temperature Control Range : | RT +5 to 70 °C |
| Capacity: | 2 microplates or culture plates |
| Speed Range: | 200 to 1600 rpm |
| Temperature Control Range: | RT +5°C to 80°C |
| Capacity: | 4 microplates or deep well plates |
| Speed Range: | 300 to 1350 rpm |
| Orbit: | 3mm |
| Capacity: | 4 enzyme standard plates or deep-well plates. |
| Speed Range : | 100 to 1600 |
| Temperature Control Range: | RT +5 to 70 °C |
| Temperature Setting Range: | 0℃ to 100℃ |
| Temperature Control Range: | RT +5℃ to 100℃ |
| Shaking Speed: | 200 to 1600 rpm |
| Speed Range: | 200 to 1500 rpm |
| Amplitude: | 2 mm, Horizontal rotation |
| Temperature Control Range: | RT+5 to 80℃ |
| Temperature Setting Range: | 0℃ to 100℃ |
| Temperature Control Range: | RT. -5℃ to 100℃ |
| Speed Range: | 200 to 2000 rpm |