| Temperature Setting Range | 0℃ to 100℃ |
| Temperature Control Range | RT. +5℃ to 100℃ |
| Speed Range | 200 to 1800 rpm |
| Temperature Accuracy | ≤ ± 0.3℃ |
| Temperature Uniformity | ≤ ± 0.3℃ |
| Orbit | 3 mm |
| Heating Time | ≤ 12min (from 25℃ to 100℃) |
| Timing Range | 1min to 99min59sec / infinite |
| Display Accuracy | 0.1 ℃ |
| Power Consumption | AC220V or AC110V, 50/60 Hz, 150W |
| Dimension (W × D × H) | 260 × 195 × 150 mm |
| Packing Dimension (W × D × H) | 400 × 300 × 300 mm |
| Net Weight | 7.0 kg |
| Gross Weight | 10 kg |
Thermo-Shaker Incubator ADTSI-503 is ideal for storing samples at ice bucket temperatures and keeping enzymes or DNA libraries stable at the workstation. It enables efficient preparation of PCR samples through precise temperature management.
| Blocks | Description
| Speed Range | Quantity |
| Block 01 | 0.2ml x 96
| 200 to 1800 rpm | 1 Pc |
| Block 02 | 0.5 ml x 54
| 200 to 1800 rpm | 1 Pc |
| Block 03 | 1.5 ml x 35
| 200 to 1800 rpm | 1 Pc |
| Block 04 | 2.0 ml x 35
| 200 to 1800 rpm | 1 Pc |
| Block 05 | 0.5 ml x 15 + 1.5 ml x 20
| 200 to 1800 rpm | 1 Pc |
| Block 06 | 0.2 ml x 96 (ELISA Plate)
| 200 to 1800 rpm | 1 Pc |
| Block 07 | 5 ml x 24
| 200 to 1000 rpm | 1 Pc |
| Block 08 | 10 ml x 15
| 200 to 1000 rpm | 1 Pc |
| Block 09 | 15 ml x 12
| 200 to 1000 rpm | 1 Pc |
| Block 10 | Round 50 ml x 6
| 200 to 800 rpm | 1 Pc |
| Block 11 | Conical 50 ml x 6
| 200 to 800 rpm | 1 Pc |
1. What types of samples can the Thermo-Shaker Incubator ADTSI-503 accommodate?
Thermo-Shaker Incubator ADTSI-503 can accommodate a variety of sample types thanks to its interchangeable block system. It supports microtubes of different volumes, PCR plates, Falcon tubes, and even cuvettes or cryotubes. This versatility makes it suitable for diverse laboratory applications. Users can easily switch blocks to match their specific sample format requirements.
2. How does the Thermo-Shaker Incubator ADTSI-503 ensure temperature accuracy and uniformity?
Thermo-Shaker Incubator ADTSI-503 ensures temperature accuracy and uniformity through precise heating elements combined with high-quality temperature sensors. These components monitor and adjust the temperature in real time, maintaining a stable environment across the entire block. The unit has a design that minimizes heat loss and promotes even distribution. This results in consistent conditions for all samples during operation.
3. Is the Thermo-Shaker Incubator ADTSI-503 safe for long-term use?
Thermo-Shaker Incubator ADTSI-503 is designed for safe long-term use with built-in safety features such as over-temperature protection and sensor diagnostics. These safeguards prevent overheating and detect any malfunctions early. The brushless motor also ensures reliable and quiet operation over extended periods. Together, these features help maintain consistent performance and protect both the device and samples.
4. Can the temperature and shaking speed be adjusted during operation in Thermo-Shaker Incubator ADTSI-503?
Thermo-Shaker Incubator ADTSI-503 allows users to adjust both temperature and shaking speed during operation without stopping the device. This real-time control provides flexibility to optimize experimental conditions as needed. The intuitive digital interface makes these adjustments quick and easy. This feature helps maintain precise and consistent sample processing throughout the run.
5. What is the maximum shaking speed of the Thermo-Shaker Incubator ADTSI-503?
Thermo-Shaker Incubator ADTSI-503 offers 200 to 1800 rpm speed range that can be adjusted to suit different sample mixing needs. It provides a smooth and stable orbital motion even at high speeds, ensuring efficient agitation. This range allows users to select gentle or vigorous shaking based on their protocols. The precise control helps maintain sample integrity throughout the process.
6. What is a Thermo-Shaker Incubator used for?
A Thermo-Shaker Incubator is used for simultaneous heating, cooling, and mixing of samples, making it ideal for applications like enzyme reactions, nucleic acid hybridization, cell lysis, and DNA/RNA extraction. It ensures uniform temperature distribution and consistent agitation, improving reaction efficiency and reproducibility. This makes it an essential tool for molecular biology, biochemistry, and clinical laboratories.
7. What are the advantages of using Thermo-Shaker Incubator?
The advantages of using a Thermo-Shaker Incubator include combining precise temperature control with adjustable shaking to ensure uniform mixing and consistent incubation conditions, thereby enhancing reaction efficiency and reproducibility. Its versatile design supports a wide range of sample types through interchangeable blocks, increasing flexibility for various applications.
| Temperature Control Range | RT -20℃ to 100℃ |
| Speed Range | 300 to 1500 rpm |
| Amplitude | 2 mm, Horizontal rotation |
| Temperature Setting Range | 0℃ to 100℃ |
| Temperature Control Range | RT. -20℃ to 100℃ |
| Speed Range | 200 to 1500 rpm |
| Temperature Control Range | RT +5℃ to 100℃ |
| Speed Range | 300 to 2000 rpm |
| Amplitude | 2 mm, Horizontal rotation |
| Speed Range: | 200 to 1500 rpm |
| Amplitude: | 2 mm, Horizontal rotation |
| Temperature Control Range: | RT+5 to 80℃ |
| Capacity: | 2 microplates or culture plates |
| Speed Range: | 200 to 1600 rpm |
| Temperature Control Range: | RT +5°C to 80°C |
| Temperature Setting Range: | 0℃ to 100℃ |
| Temperature Control Range: | RT +5℃ to 100℃ |
| Shaking Speed: | 200 to 1600 rpm |
| Capacity: | 4 enzyme standard plates or deep-well plates. |
| Speed Range : | 100 to 1600 |
| Temperature Control Range: | RT +5 to 70 °C |
| Capacity: | 4 microplates or deep well plates |
| Speed Range: | 300 to 1350 rpm |
| Orbit: | 3mm |
| Capacity: | 2 enzyme standard plates or deep-well plates |
| Speed Range: | 100 to 1600 |
| Temperature Control Range : | RT +5 to 70 °C |
| Temperature Setting Range: | 0℃ to 100℃ |
| Temperature Control Range: | RT. -5℃ to 100℃ |
| Speed Range: | 200 to 2000 rpm |