Thermo-Shaker Incubator ADTSI-503

Thermo-Shaker Incubator ADTSI-503

Thermo-Shaker Incubator ADTSI-503 allows temperature settings ranging from 0℃ to 100℃ for precise thermal regulation. It has modular block design that supports a variety of tube types, enhancing versatility. This system uses a brushless motor for quiet and reliable performance. Designed to enhance operational safety, it includes automatic fault detection with a buzzer alarm function. Our Thermo-Shaker Incubator is used for precise heating and mixing of biological and chemical samples in laboratories.


Temperature Setting Range 0℃ to 100℃
Temperature Control Range RT. +5℃ to 100℃
Speed Range 200 to 1800 rpm
Temperature Accuracy ≤ ± 0.3℃
Temperature Uniformity ≤ ± 0.3℃
Orbit 3 mm
Heating Time ≤ 12min (from 25℃ to 100℃)
Timing Range 1min to 99min59sec / infinite
Display Accuracy 0.1 ℃
Power Consumption AC220V or AC110V, 50/60 Hz, 150W
Dimension (W × D × H) 260 × 195 × 150 mm
Packing Dimension (W × D × H) 400 × 300 × 300 mm
Net Weight 7.0 kg
Gross Weight 10 kg

Thermo-Shaker Incubator ADTSI-503 is ideal for storing samples at ice bucket temperatures and keeping enzymes or DNA libraries stable at the workstation. It enables efficient preparation of PCR samples through precise temperature management.

Blocks

Description

 

Speed RangeQuantity
Block 01

0.2ml x 96

 

200 to 1800 rpm1 Pc
Block 02

0.5 ml x 54

 

200 to 1800 rpm1 Pc
Block 03

1.5 ml x 35

 

200 to 1800 rpm1 Pc
Block 04

2.0 ml x 35

 

200 to 1800 rpm1 Pc
Block 05

0.5 ml x 15 + 1.5 ml x 20

 

200 to 1800 rpm1 Pc
Block 06

0.2 ml x 96 (ELISA Plate)

 

200 to 1800 rpm1 Pc
Block 07

5 ml x 24

 

200 to 1000 rpm1 Pc
Block 08

10 ml x 15

 

200 to 1000 rpm1 Pc
Block 09

15 ml x 12

 

200 to 1000 rpm1 Pc
Block 10

Round 50 ml x 6

 

200 to 800 rpm1 Pc
Block 11

Conical 50 ml x 6

 

200 to 800 rpm1 Pc

Frequently Asked Questions of Thermo-Shaker Incubator ADTSI-503

1. What types of samples can the Thermo-Shaker Incubator ADTSI-503 accommodate?

Thermo-Shaker Incubator ADTSI-503 can accommodate a variety of sample types thanks to its interchangeable block system. It supports microtubes of different volumes, PCR plates, Falcon tubes, and even cuvettes or cryotubes. This versatility makes it suitable for diverse laboratory applications. Users can easily switch blocks to match their specific sample format requirements.

2. How does the Thermo-Shaker Incubator ADTSI-503 ensure temperature accuracy and uniformity?

Thermo-Shaker Incubator ADTSI-503 ensures temperature accuracy and uniformity through precise heating elements combined with high-quality temperature sensors. These components monitor and adjust the temperature in real time, maintaining a stable environment across the entire block. The unit has a design that minimizes heat loss and promotes even distribution. This results in consistent conditions for all samples during operation.

3. Is the Thermo-Shaker Incubator ADTSI-503 safe for long-term use?

Thermo-Shaker Incubator ADTSI-503 is designed for safe long-term use with built-in safety features such as over-temperature protection and sensor diagnostics. These safeguards prevent overheating and detect any malfunctions early. The brushless motor also ensures reliable and quiet operation over extended periods. Together, these features help maintain consistent performance and protect both the device and samples.

4. Can the temperature and shaking speed be adjusted during operation in Thermo-Shaker Incubator ADTSI-503?

Thermo-Shaker Incubator ADTSI-503 allows users to adjust both temperature and shaking speed during operation without stopping the device. This real-time control provides flexibility to optimize experimental conditions as needed. The intuitive digital interface makes these adjustments quick and easy. This feature helps maintain precise and consistent sample processing throughout the run.

5. What is the maximum shaking speed of the Thermo-Shaker Incubator ADTSI-503?

Thermo-Shaker Incubator ADTSI-503 offers 200 to 1800 rpm speed range that can be adjusted to suit different sample mixing needs. It provides a smooth and stable orbital motion even at high speeds, ensuring efficient agitation. This range allows users to select gentle or vigorous shaking based on their protocols. The precise control helps maintain sample integrity throughout the process.

6. What is a Thermo-Shaker Incubator used for?

A Thermo-Shaker Incubator is used for simultaneous heating, cooling, and mixing of samples, making it ideal for applications like enzyme reactions, nucleic acid hybridization, cell lysis, and DNA/RNA extraction. It ensures uniform temperature distribution and consistent agitation, improving reaction efficiency and reproducibility. This makes it an essential tool for molecular biology, biochemistry, and clinical laboratories.

7. What are the advantages of using Thermo-Shaker Incubator?

The advantages of using a Thermo-Shaker Incubator include combining precise temperature control with adjustable shaking to ensure uniform mixing and consistent incubation conditions, thereby enhancing reaction efficiency and reproducibility. Its versatile design supports a wide range of sample types through interchangeable blocks, increasing flexibility for various applications.

Similar Products of Thermo-Shaker Incubator

Temperature Control Range RT -20℃ to 100℃
Speed Range 300 to 1500 rpm
Amplitude 2 mm, Horizontal rotation
Temperature Setting Range 0℃ to 100℃
Temperature Control Range RT. -20℃ to 100℃
Speed Range 200 to 1500 rpm
Temperature Control Range RT +5℃ to 100℃
Speed Range 300 to 2000 rpm
Amplitude 2 mm, Horizontal rotation

Microplate Thermo-Shaker

Microplate Thermo-Shaker ADMTS-501
Speed Range:200 to 1500 rpm
Amplitude: 2 mm, Horizontal rotation
Temperature Control Range:RT+5 to 80℃
Microplate Thermo-Shaker ADMTS-504
Capacity:2 microplates or culture plates
Speed Range:200 to 1600 rpm
Temperature Control Range:RT +5°C to 80°C
Microplate Thermo-Shaker ADMTS-506
Temperature Setting Range:0℃ to 100℃
Temperature Control Range:RT +5℃ to 100℃
Shaking Speed:200 to 1600 rpm
Microplate Thermo-Shaker ADMTS-503
Capacity:4 enzyme standard plates or deep-well plates.
Speed Range :100 to 1600
Temperature Control Range:RT +5 to 70 °C
Microplate Thermo-Shaker ADMTS-505
Capacity:4 microplates or deep well plates
Speed Range:300 to 1350 rpm
Orbit:3mm
Microplate Thermo-Shaker ADMTS-502
Capacity:2 enzyme standard plates or deep-well plates
Speed Range:100 to 1600
Temperature Control Range :RT +5 to 70 °C

Heating Lid Thermo-Shaker

Heating Lid Thermo-Shaker ADHLT-502
Temperature Setting Range:0℃ to 100℃
Temperature Control Range:RT. -5℃ to 100℃
Speed Range:200 to 2000 rpm