| Temperature Control Range | RT +5℃ to 100℃ |
| Speed Range | 300 to 2000 rpm |
| Amplitude | 2 mm, Horizontal rotation |
| Timer | 1 min to 99 h 59 min / 0: infinite time |
| Temperature Accuracy | ±0.3℃ |
| Temperature Stability |
±0.3℃ at 40℃ ±0.3℃ at 100℃ |
| Temperature Control Mode | Heating membrane |
| Heating Up Rate | < 15 min, 25℃ to 100℃ |
| Temperature Set Range | 5 to 100°C |
| Display Accuracy | 0.1℃ |
| Power Consumption | 180 W |
| Dimension (W×D×H) | 220×300×170 mm |
| Packing Dimension (W × D × H) | 400 × 300 × 300 mm |
| Net Weight | 8.3 kg |
| Gross Weight | 11 kg |
Our Thermo-Shaker Incubator ADTSI-502 is well-suited for sample incubation, catalysis, mixing, and preservation in molecular biology workflows.
Accessory | Description | Maximum Temperature | Maximum Speed | Quantity |
Block 01 | 96 × 0.2ml PCR plate (φ6.7×16) | 100℃ | 2000 rpm | 1 Pc |
Block 02 | 54 × 0.5ml tubes (φ8×23) | 100℃ | 2000 rpm | 1 Pc |
Block 03 | 35 × 1.5ml tubes (φ10.8×31) | 100℃ | 2000 rpm | 1 Pc |
Block 04 | 35 × 2.0ml tubes (φ10.8×31) | 100℃ | 2000 rpm | 1 Pc |
Block 05 | 20 × 0.5ml + 15 × 1.5ml tubes | 100℃ | 2000 rpm | 1 Pc |
Block 06 | 24 × φ12mm × 30 tubes | 100℃ | 2000 rpm | 1 Pc |
Block 07 | 32 × 0.2ml + 25 × 1.5ml tubes | 100℃ | 2000 rpm | 1 Pc |
Block 08 | 32 × 0.2ml + 10 × 0.5ml + 15 × 1.5ml tubes | 100℃ | 2000 rpm | 1 Pc |
Block 09 | 32 × 0.2ml + 10 × 0.5ml + 15 × 2.0ml tubes | 100℃ | 2000 rpm | 1 Pc |
Block 10 | 103 × 67 × 30 (water tank) | 100℃ | 2000 rpm | 1 Pc |
Block 11 | 96 × 0.2ml Elisa (Flat bottom) | 100℃ | 2000 rpm | 1 Pc |
Block 12 | 24 × 5ml (φ13.5×30) | 100℃ | 2000 rpm | 1 Pc |
Block 13 | 12 × 15ml (φ16.9×98) | 100℃ | 700 rpm | 1 Pc |
Block 14 | 6 × 50ml (φ29.5×90) | 100℃ | 700 rpm | 1 Pc |
Block 15 | 12 × 10ml (φ15.9×65) | 100℃ | 700 rpm | 1 Pc |
Lid A | 152 × 113 × 45 | - | - | 1 Pc |
Lid B | 145 × 105 × 62.5 | - | - | 1 Pc |
Lid C | 145 × 105 × 122.5 | - | - | 1 Pc |
1. Which temperature control technology is employed by the Thermo-Shaker Incubator?
This Thermo-Shaker Incubator uses heating membrane technology for precise and stable temperature control. This advanced system enables rapid temperature adjustments and maintains consistent performance during experiments.
2. What is the horizontal rotation amplitude of the Thermo-Shaker Incubator?
Our Thermo-Shaker Incubator features a 2 mm horizontal rotation amplitude, promoting consistent and efficient sample mixing. This precise movement ensures uniform treatment of samples, enhancing experimental accuracy. The gentle rotation reduces sample disturbance and prevents spillage.
3. Does the Thermo-Shaker Incubator include various interchangeable blocks?
Yes, it includes a variety of interchangeable blocks designed for easy swapping, enhancing versatility and adaptability for different sample types. These blocks allow users to customize the unit to fit specific experimental needs. Their quick interchangeability also helps save time and increase lab efficiency.
4. Is the Thermo-Shaker Incubator portable?
Yes, our Thermo-Shaker Incubator is designed to be portable, allowing easy transport and convenient use across different laboratory settings. Its compact and lightweight design ensures it fits comfortably on benchtops without occupying much space. This portability enhances flexibility in lab workflows and facilitates experiments in various locations.
5. Does the Thermo-Shaker Incubator feature a digital display?
Yes, our Thermo-Shaker Incubator is equipped with an advanced digital display, allowing easy monitoring and precise control of operational settings. This user-friendly interface enhances accuracy and simplifies experiment management.
6. What is a Thermo-Shaker Incubator used for?
A Thermo-Shaker Incubator is used for simultaneous heating, cooling, and mixing of samples, making it ideal for applications like enzyme reactions, nucleic acid hybridization, cell lysis, and DNA/RNA extraction. It ensures uniform temperature distribution and consistent agitation, improving reaction efficiency and reproducibility. This makes it an essential tool for molecular biology, biochemistry, and clinical laboratories.
7. What are the advantages of using Thermo-Shaker Incubator?
The advantages of using a Thermo-Shaker Incubator include combining precise temperature control with adjustable shaking to ensure uniform mixing and consistent incubation conditions, thereby enhancing reaction efficiency and reproducibility. Its versatile design supports a wide range of sample types through interchangeable blocks, increasing flexibility for various applications.
| Temperature Setting Range | 0℃ to 100℃ |
| Temperature Control Range | RT. +5℃ to 100℃ |
| Speed Range | 200 to 1800 rpm |
| Temperature Control Range | RT -20℃ to 100℃ |
| Speed Range | 300 to 1500 rpm |
| Amplitude | 2 mm, Horizontal rotation |
| Temperature Setting Range | 0℃ to 100℃ |
| Temperature Control Range | RT. -20℃ to 100℃ |
| Speed Range | 200 to 1500 rpm |
| Speed Range: | 200 to 1500 rpm |
| Amplitude: | 2 mm, Horizontal rotation |
| Temperature Control Range: | RT+5 to 80℃ |
| Capacity: | 2 enzyme standard plates or deep-well plates |
| Speed Range: | 100 to 1600 |
| Temperature Control Range : | RT +5 to 70 °C |
| Temperature Setting Range: | 0℃ to 100℃ |
| Temperature Control Range: | RT +5℃ to 100℃ |
| Shaking Speed: | 200 to 1600 rpm |
| Capacity: | 2 microplates or culture plates |
| Speed Range: | 200 to 1600 rpm |
| Temperature Control Range: | RT +5°C to 80°C |
| Capacity: | 4 microplates or deep well plates |
| Speed Range: | 300 to 1350 rpm |
| Orbit: | 3mm |
| Capacity: | 4 enzyme standard plates or deep-well plates. |
| Speed Range : | 100 to 1600 |
| Temperature Control Range: | RT +5 to 70 °C |
| Temperature Setting Range: | 0℃ to 100℃ |
| Temperature Control Range: | RT. -5℃ to 100℃ |
| Speed Range: | 200 to 2000 rpm |