Automatic Slide Stainer ADAS-504

Automatic Slide Stainer ADAS-504

Automatic Slide Stainer ADAS-504 handles 62 slides per cycle, supporting fast and large-volume workflows. It offers flexible program settings, allowing technicians to define conditions according to laboratory protocols. Each unit supports adjustable duration control, providing adaptability across various staining techniques. The system features an intelligent self-check and reset's function, delivering stable and trouble-free operation. Designed for histology and diagnostic centers, it ensures precise slide processing for accurate microscopic evaluation.


Loading Capacity 62 samples per run
Single Cylinder Capacity 1000 mL
Cylinder Positions 14 in total, 1 washing cylinder (first) and 1 drying cylinder (last)
Programmable Settings Up to 16 editable programs, freely configurable
Processing Time Adjustable from 0 to 99 minutes 99 seconds
Drying Temperature Adjustable from 0 to 85 °C
Shaking Function Cylinder shaking time adjustable
Stirring Function Stirring times adjustable
Drip Residence Time Adjustable from 0 to 300 seconds
Packaging Each unit packed in a wooden case
Power Consumption <300 W
Power Supply 220 V, 50 Hz 10%
Packaging Dimensions (W × D × H) 1310 × 660 × 700 mm
Gross Weight 110 kg
  • Color touch display
  • ATM-style operation
  • Auto water level
  • Cylinder lock protection
  • Belt drive system

The Automatic Slide Stainer ADAS-504 is built for histopathology and clinical labs, offering fast tissue slide staining with reliable consistency to support precise microscopic evaluations.

Automatic Slide Stainer ADAS-504 | Loading Capacity 62 samples per run | Single Cylinder Capacity 1000 mL
Automatic Slide Stainer ADAS-504 | Color touch display | ATM-style operation

Frequently Asked Questions of Automatic Slide Stainer ADAS-504

1. What is the slide handling capacity of the Automatic Slide Stainer ADAS-504?

Automatic Slide Stainer ADAS-504 can manage 62 slides in a single run, supporting laboratories with heavy workloads. This feature ensures efficient use of time by processing multiple samples together without compromising quality. By accommodating such a large volume, the unit helps laboratories meet daily staining demands with ease. Its design allows smooth transitions between batches for uninterrupted workflow.

2. How does the color touch display benefit the user of the Automatic Slide Stainer ADAS-504?

Automatic Slide Stainer ADAS-504 is equipped with a full-color touch screen, making operation clear and straightforward. The display ensures quick access to functions, minimizing errors during program selection. With its intuitive design, both new and experienced users can navigate settings without difficulty. This modern interface shortens training time while increasing efficiency in day-to-day tasks.

3. What is the purpose of the ATM-style operation mode in the Automatic Slide Stainer ADAS-504?

Automatic Slide Stainer ADAS-504 uses an ATM-style interface for enhanced usability. This familiar system simplifies programming, making it approachable for users at any skill level. By reducing complexity, it ensures consistent operation across various staining tasks. The design minimizes the learning curve, allowing laboratories to start using the equipment quickly.

4. How does the automatic water level control work in the Automatic Slide Stainer ADAS-504?

Automatic Slide Stainer ADAS-504 features an advanced automatic water level regulation system. It automatically fills the washing tank when required, preventing manual adjustments. Once the washing cycle is complete, the system drains the tank to maintain cleanliness. This feature guarantees consistent washing results for every batch of slides.

5. What makes the belt drive system advantageous in the Automatic Slide Stainer ADAS-504?

Automatic Slide Stainer ADAS-504 integrates a synchronous toothed belt drive for superior performance. This mechanism reduces noise, creating a quieter laboratory environment. Its robust design withstands both high temperatures and corrosive conditions. The belt ensures accurate, long-lasting operation while minimizing maintenance needs.

6. What are Automatic Slide Stainers?

Automatic Slide Stainers are lab equipment designed to process multiple glass slides simultaneously, applying reagents and stains in a controlled and consistent manner. They streamline the staining process, reduce manual handling, and improve efficiency in high-volume laboratories. These units help maintain uniform staining quality across all slides in a batch.

7. What are the applications of Automatic Slide Stainers?

Automatic Slide Stainers are widely used in pathology, histopathology, and clinical laboratories for the preparation of tissue and cell slides. They support a variety of staining techniques to ensure accurate microscopic analysis. These systems are ideal for laboratories that require high throughput slide processing with reliable and reproducible results.

Similar Products of Automatic Slide Stainer

Dyeing Frame Capacity 30 glass slides
Reagent Sites 26
Washing Sites 5
Capacity 12 slides, up to 180/hour
Sample Tray Capacity 1 to 12 / 16 / 24 slides depending on configuration
Solution Efficiency 600 to 1000 slides
Slide Rack Capacity >75 slides
Reagent Tanks 18 cylinders
Tank Volume 1000 ml
Specimen Slide Throughput 400 slides per hour
Sample Capacity 30 slides per rack
Rack Capacity 11 slide racks

Mini Slide Stainer

Mini Slide Stainer ADMSS-501
Number of Cylinders:15
Cylinder Details :1 starting protection <br> 5 cleaning <br> 1 hematoxylin <br> 1 differentiation <br> 1 eosin <br> 1 Blue Back <br> 4 gradient alcohol <br> 1 ending
Cylinder Arrangement :2nd, 4th, 6th, 8th, 10th: cleaning <br> 3rd: hematoxylin <br> 5th: differentiation <br> 7th: Blue Back <br> 9th: eosin <br> 11th to 14th: gradient alcohol <br> 15th: ending