| External Dimension (L×B×H) | 500×575×580 mm |
| Internal Dimension (L×B×H) | 490×530×400 mm |
| Surface Wind Speed | 0.5 m/h |
| Frequency | 50 to 60 Hz |
| Air Treatment | 230 m³/h |
| Noise | 50 db |
| Electric Current | 10 A |
| Type of Filter | H14 |
| Fan Power | 48 W to 110 W |
| Clean Cabinet | MPPS test shows 99.995% filtration efficiency for particles ≥0.3 microns. |
| Work Top | 1.25 mm stainless steel worktop; non-conductive and corrosion resistant. |
| High-Efficiency Particle Filter | HEPA H14 filter ensures 99.995% efficiency for particles ≥0.3 µm. |
| Pre particle Filter | 40% filtration efficiency for particles >0.3 µm. |
| Power Supply | 110 to 240 V |
Our Vertical Laminar Airflow Cabinet ADVL-501 is used in forensic science, academic institutions and quality control testing to ensure a sterile and controlled environment for contamination-sensitive tasks.
1. What is the purpose of the Vertical Laminar Air Flow Cabinet ADVL-501?
The Vertical Laminar Air Flow Cabinet ADVL-501 is designed to provide a sterile, particle-free working environment using vertical HEPA-filtered airflow. It protects sensitive samples and processes from airborne contaminants. This unit is commonly used in microbiology, biotechnology, and electronics. The vertical airflow design ensures contaminants are pushed downward and away from the workspace. It is ideal for operations requiring Class 100 (ISO 5) clean air conditions.
2. What type of filtration does the Vertical Laminar Air Flow Cabinet ADVL-501 use?
The cabinet is equipped with a high-efficiency HEPA H14 filter, which removes 99.995% of airborne particles ?0.3 microns. This ensures a clean and sterile workspace for sensitive procedures. It also often includes a pre-filter to trap larger particles and extend the HEPA filter's life. The filtered air flows vertically from top to bottom, reducing the risk of cross-contamination. This filtration setup complies with international cleanroom standards.
3. Is the Vertical Laminar Air Flow Cabinet ADVL-501 safe for handling hazardous substances?
No, the Vertical Laminar Air Flow Cabinet ADVL-501 is not designed for handling hazardous chemicals, toxic fumes, or biohazards. It is meant to protect the product—not the user or environment. Operators should not use volatile or flammable substances inside this cabinet. For hazardous material handling, a biosafety cabinet or fume hood is more appropriate. Always refer to the safety guidelines provided with the equipment.
4. What are the power and airflow specifications of the Vertical Laminar Air Flow Cabinet ADVL-501?
The Vertical Laminar Air Flow Cabinet ADVL-501 typically operates with a fan power ranging from 48 W to 110 W and delivers a consistent air velocity of about 0.45 to 0.6 m/s. It ensures uniform airflow across the entire workspace. The airflow rate and velocity can sometimes be adjusted depending on the model and application. This balance maintains cleanliness while conserving energy. The cabinet also operates with low noise and vibration levels for user comfort.
5. What maintenance does the Vertical Laminar Air Flow Cabinet ADVL-501 require?
Regular maintenance includes cleaning the surfaces with disinfectants, checking airflow using anemometers, and replacing filters as needed. The pre-filter should be checked monthly and replaced if clogged. HEPA filters generally need replacement every 6 to 12 months based on usage. UV lamp (if equipped) should also be checked regularly for effectiveness. Proper maintenance ensures optimal performance and contamination control.
| External Dimension (L×B×H) | 1200×550×1600 mm |
| Internal Dimension (L×B×H) | 1150×500×460 mm |
| Surface Wind Speed | 0.5 m/h |
| External Dimension (L×B×H) | 800×575×580 mm |
| Internal Dimension (L×B×H) | 790×530×400 mm |
| Surface Wind Speed | 0.5 m/h |
| External Dimension (L×B×H) | 1200×575×580 mm |
| Internal Dimension (L×B×H) | 1190×530×400 mm |
| Surface Wind Speed | 0.5 m/h |
| External Dimension (L×B×H) | 1000×550×1600 mm |
| Internal Dimension (L×B×H) | 950×500×460 mm |
| Surface Wind Speed | 0.5 m/h |
| Velocity: | 0.3 to 0.6 m/s |
| Half Peak Amplitude: | ≤ 3µm |
| Number of Colonies: | ≤ 0.5 dish/hr |
| Velocity: | 0.3 to 0.6 m/s |
| Half Peak Amplitude: | ≤ 3µm |
| Number of Colonies: | ≤ 0.5 dish/hr |
| Internal Dimensions (W×D×H): | 1570×480×570 mm |
| Exterior Dimensions (W×D×H): | 1570×790×1380 mm |
| Airflow Direction: | Horizontal |
| Velocity: | 0.3 to 0.6 m/s |
| Half Peak Amplitude: | ≤ 3µm |
| Number of Colonies: | ≤ 0.5 dish/hr |
| Internal Dimensions (W×D×H): | 910×480×570 mm |
| Exterior Dimensions (W×D×H): | 910×790×1380 mm |
| Airflow Direction: | Horizontal |
| Velocity: | 0.3 to 0.6 m/s |
| Half Peak Amplitude: | ≤ 3µm |
| Number of Colonies: | ≤ 0.5 dish/hr |