Refrigerated Low-Speed Centrifuge ADRLC-502 offers a maximum speed of 5,000 rpm, providing efficient and reliable sample processing. Our centrifuge accommodates up to 4 containers each with a 750 ml capacity for high-volume samples. It features a 316 stainless steel chamber with a Teflon coating for enhanced corrosion resistance. Our centrifuge offers customizable programs for 1,000 user-defined settings and tracking up to 100,000 run histories.
Max Speed | 5000 rpm |
Max RCF | 5201× g |
Max Capacity | 4x750 ml |
Speed Accuracy | ±10 rpm |
Temperature Range | -20°C to +40°C |
Temperature Accuracy | ±1℃ |
Time Setting | 1s to 99h59m59s |
Noise | ≤56 dB(A) |
Power Consumption | 1500W |
Dimension | 600x680x420 mm |
Weight | 108 kg |
Refrigerated Low-Speed Centrifuge ADRLC-502 is used for sample separation and is widely used in Clinical Laboratories, Research Institutions, Pharmaceutical and Biotech Labs, Universities, and Educational Labs.
Refrigerated Low-Speed Centrifuge ADRLC-502 is used for sample separation and is widely used in Clinical Laboratories, Research Institutions, Pharmaceutical and Biotech Labs, Universities, and Educational Labs.
Rotor Type | Capacity | Max Speed (rpm) | Max RCF (×g) |
Swing-out Rotor 01 | 4×100ml | 5000rpm | 4650×g |
Swing-out Rotor 02 | 4×50ml | 5000rpm | 4650×g |
Swing-out Rotor 03 | 32×15ml | 4000rpm | 2980×g |
Swing-out Rotor 04 | 8×50ml | 4000rpm | 2980×g |
Swing-out Rotor 05 | 8×100ml | 4000rpm | 2980×g |
Swing-out Rotor 06 | 48×2~7ml blood tube | 4000rpm | 3100×g |
Swing-out Rotor 07 | 64×2~7ml blood tube | 4000rpm | 3100×g |
Swing-out Rotor 08 (with lid) | 4×250ml | 5000rpm | 5201×g |
Swing-out Rotor 09 | 4×500ml | 4200rpm | 3551×g |
Swing-Bucket Rotor 01 | 20×50ml | 4200rpm | 3551×g |
Swing-Bucket Rotor 02 | 40×15ml | 4200rpm | 3551×g |
Swing-Bucket Rotor 03 | 80×10ml blood tube | 4200rpm | 3551×g |
Swing-Bucket Rotor 04 | 112×2 to 7ml blood tube | 4200rpm | 3551×g |
Swing-Bucket Rotor 05 | 100×1.5ml | 4200rpm | 3551×g |
Swing-out Rotor 10 | 4×750ml | 4000rpm | 3500×g |
Swing-out Rotor 11 | 6×250ml | 4000rpm | 3581×g |
Swing-out Rotor 12 | 148×5ml RIA tube | 4200rpm | 3551×g |
Swing-out Rotor 13 | 96×2~7ml blood tube | 4200rpm | 3551×g |
Swing-out Rotor 14 | 4×250ml conical bottom | 4200rpm | 3551×g |
Microplate Rotor 01 | 2×3×96 well plates | 4000rpm | 1971×g |
Microplate Rotor 02 | 4×2×96 well plates | 4200rpm | 3551×g |
Adapter No. | Adapter Capacity |
Adapter 01 | 8x50ml |
Adapter 02 | 4x100ml |
Adapter 03 | 36x10ml |
Adapter 04 | 40x7ml blood tube |
Adapter 05 | 20x15ml |
Adapter 06 | 16×50ml |
Adapter 07 | 16×50ml |
Adapter 08 | 36×15ml |
Adapter 09 | 36×15ml |
Adapter 10 | 76×2 to 7ml blood tubes |
Adapter 11 | 76×2 to 7ml blood tubes |
Adapter 12 | 12×100ml |
Adapter 13 | 20×50ml |
Adapter 14 | 56×15ml |
Adapter 15 | 28×50ml |
Adapter 16 | 96x2 to 7ml blood tube |
Max Speed Range | 6000 rpm |
Max RCF | 6880 × g |
Max Capacity | 6 × 1000 ml |
Max Capacity | 4 tubes, each 1000 ml |
Max Speed | 6000 rpm |
Max RCF | 6693×g |
Max Speed | 5000 rpm |
Max RCF | 5200 × g |
Max Capacity | 4 × 800 ml |
Max Speed | 6000 rpm |
Max RCF | 5201× g |
Max Capacity | 4x750 ml |
Max Speed | 6000 rpm |
Max RCF | 5123× g |
Max Capacity | 4x250 ml |
Max Speed | 8000 rpm |
Max RCF | 14500 × g |
Max Capacity | 6x2400 ml / 12 blood bags / 384 blood tubes |
Max Speed: | 21000 rpm |
Max RCF: | 47400 x g |
Max Capacity: | 6x500 ml |
Temperature Range: | -20°C to +40°C |
Max Speed: | 16,500 rpm |
Max RCF: | 24,760 × g |
Max Capacity: | 6 x 100 mL |
Temperature Range: | -20°C to +40°C |
Max Speed: | 10000 rpm |
Max RCF: | 18590 x g |
Max Capacity: | 6x1000 ml |
Temperature Range: | -20°C to +40°C |
Max Speed: | 4500 rpm |
Max RCF: | 3380 x g |
Max Capacity: | 6 x 50 ml syringe |
Speed Accuracy: | ± 10 rpm |
Max Speed: | 4700 rpm |
Max RCF: | 2000 xg |
Max Capacity: | 12 x 7 ml (SERO rotor) |
Speed Accuracy: | ±20 rpm |
Max Speed: | 4000 rpm |
Max RCF: | 3400 xg |
Max Capacity: | 4 x 200 ml |
Speed Accuracy: | ±10 rpm |