| Maximum Speed | 5000 rpm |
| Maximum RCF | 4650 × g |
| Maximum Capacity | 4 × 250 ml |
| Speed Accuracy | ±10 rpm |
| Time Setting | 1s to 99h59m59s/Pulse |
| Noise | ≤60 dB(A) |
| Power Consumption | 500 W |
| Dimensions(L×B×H) | 550 x 430 x 350 mm |
| Weight | 39 kg |
Our Low-Speed Centrifuge ADLSC-507 is widely used in research institutions, environmental testing, and educational settings for efficient separation of biological samples and cells.
Rotor | Capacity | Maximum Speed | Maximum RCF | Tube Size |
Swing Out Rotor 01 | 4×100ml | 4000rpm | 4650×g | Φ38×114mm |
Swing Out Rotor 02 | 4×50ml | 4000rpm | 4650×g | Φ30×116mm |
Swing Out Rotor 03 | 32×15ml | 4000rpm | 2980×g | Φ17×121mm |
Swing Out Rotor 04 | 24×15ml | 4000rpm | 2980×g | Φ17×121mm |
Swing Out Rotor 05 | 8×50ml | 4000rpm | 2980×g | Φ30×116mm |
Swing Out Rotor 06 | 8×100ml | 4000rpm | 2980×g | Φ38×114mm |
Swing Out Rotor 07 | 4×250ml | 4000rpm | 2980×g | Φ63×111mm |
Swing Out Rotor 08 | 48×2 to 7ml blood tube | 4000rpm | 2980×g | Φ13×75 to 100mm |
Swing Out Rotor 09 | 64×2 to 7ml blood tube | 4000rpm | 2980×g | Φ13×75 to 100mm |
Microplate rotor 01 | 2×3×96 well plate | 4000rpm | 1971×g | - |
1. Is the Low-Speed Centrifuge ADLSC-507 safe to operate?
Yes, the Low-Speed Centrifuge ADLSC-507 is designed with several safety features to ensure reliable and secure operation. It includes a lid locking system that prevents the lid from opening while the rotor is spinning. The imbalance detection system helps automatically stop the machine if an uneven load is detected. This prevents damage to the unit and ensures operator safety. It also features auto-stop during malfunction for added protection.
2. What are the common applications of the Low-Speed Centrifuge ADLSC-507?
This centrifuge is widely used for blood separation, urine sedimentation, and sample clarification in medical, research, and industrial labs. It is especially useful in clinical diagnostics for separating plasma or serum. In research, it aids in isolating cells, microorganisms, and other particles from solutions. Its gentle yet effective centrifugal force makes it ideal for delicate biological samples. The unit’s versatility suits both routine and specialized lab tasks.
3. How easy is it to use and maintain the Low-Speed Centrifuge ADLSC-507?
The Low-Speed Centrifuge ADLSC-507 is user-friendly, with a clear digital or analog control panel for adjusting speed and time settings. Its compact design allows for easy placement on lab benches without taking up much space. Maintenance is minimal and generally involves cleaning the rotor chamber and checking for wear. The motor and electronic components are built for long-term use with consistent performance. Regular calibration and inspection ensure optimal functioning.
4. Does the Low-Speed Centrifuge ADLSC-507 support different tube sizes or rotors?
Yes, the centrifuge supports interchangeable rotors and adapters, allowing use with a variety of tube sizes and volumes. This makes it flexible for different sample types and research requirements. Whether using small 1.5 mL tubes or larger 15 mL ones, users can easily switch rotors as needed. The design ensures secure placement and balance of tubes during operation. This adaptability adds to the centrifuge’s value in multi-purpose labs.
5. Is the Low-Speed Centrifuge ADLSC-507 noisy during operation?
The Low-Speed Centrifuge ADLSC-507 is engineered to operate quietly, producing low noise levels even at high speeds. Its brushless motor and sound-dampening design reduce vibration and sound during runs. This makes it suitable for use in quiet lab environments or shared workspaces. Consistent low-noise operation also ensures user comfort during prolonged usage. Any unusual noise may indicate imbalance or maintenance issues and should be checked.
6. Is the Low Speed Centrifuge ADSLC-507 noisy during operation?
No, the Low Speed Centrifuge ADSLC-507 is designed with low-noise motor technology. This allows the Low Speed Centrifuge ADSLC-507 to operate quietly, even during long runs.
7. Is the Low Speed Centrifuge ADSLC-507 suitable for educational use?
Yes, the Low Speed Centrifuge ADSLC-507 is simple to operate and safe, making it suitable for school, college, and university labs. Students can learn basic centrifugation techniques using the Low Speed Centrifuge ADSLC-507.
8. What is a Low Speed Centrifuge used for?
A Low Speed Centrifuge is primarily used for the separation of biological samples like blood, urine, or cells at lower speeds. Low Speed Centrifuge machines are ideal for routine separation tasks in clinical and research laboratories.
9. Can I use a Low Speed Centrifuge for blood sample separation?
Yes, a Low Speed Centrifuge is commonly used for separating blood components like plasma and serum. The gentle speed of a Low Speed Centrifuge ensures that blood cells are not damaged during the process.
10. What types of tubes are compatible with a Low Speed Centrifuge?
A Low Speed Centrifuge is compatible with various tube types such as conical, round-bottom, and standard test tubes. Always ensure that the tubes used in the Low Speed Centrifuge are balanced properly.
| Maximum Speed | 5000 rpm |
| Maximum RCF | 4650 × g |
| Maximum Capacity | 6 × 50 ml |
| Maximum Speed | 6000 rpm |
| Maximum RCF | 5200 × g |
| Maximum Capacity | 4 × 500 ml |
| Maximum Speed | 6000 rpm |
| Maximum RCF | 5201x g |
| Maximum Capacity | 4x800 ml |
| Maximum Speed | 4200 rpm |
| Maximum RCF | 2680 × g |
| Maximum Capacity | 24x10ml blood tube |
| Maximum Speed: | 19,000 rpm |
| Maximum RCF: | 30,367× g |
| Maximum Capacity: | 4 x 500 ml |
| Maximum Speed: | 16,500 rpm |
| Maximum RCF: | 24,814 × g |
| Maximum Capacity: | 6 × 100ml |
| Maximum Speed: | 20,000 RPM |
| Maximum RCF: | 31,405 × g |
| Maximum Capacity: | 6 × 100 ml |
| Max Speed: | 10000 rpm |
| Max RCF: | 18590 x g |
| Max Capacity: | 6x1000 ml |
| Maximum Speed: | 15,000 rpm |
| Maximum RCF: | 21,630 × g |
| Maximum Capacity: | 12 × 5 ml |
| Maximum Speed: | 30000 rpm |
| Maximum RCF: | 65000 × g |
| Maximum Capacity: | 4×1000ml |
| Max Speed: | 22000 rpm |
| Max RCF: | 33873x g |
| Max Capacity: | 4x750ml |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 21630 x g |
| Maximum Capacity: | 12 x 10 mL |
| Maximum Speed: | 18000 rpm |
| Maximum RCF: | 29684 × g |
| Maximum Capacity: | 6 × 100 ml |
| Max Speed: | 22000 rpm |
| Max RCF: | 52050 x g |
| Max Capacity: | 6x500 ml |
| Maximum Speed Range: | 14,000 rpm |
| Maximum RCF: | 18,800 × g |
| Maximum Capacity: | 12 × 5 ml |
| Max Speed: | 21000 rpm |
| Max RCF: | 47400 x g |
| Max Capacity: | 6x500 ml |
| Maximum Speed: | 23,000 rpm |
| Maximum RCF: | 37,023 x g |
| Maximum Capacity: | 4 x 750 ml |
| Maximum Speed: | 22,000 RPM |
| Maximum RCF: | 33,873 × g |
| Maximum Capacity: | 6 × 100 mL |
| Max Speed: | 18000 rpm |
| Max RCF: | 31405 x g |
| Max Capacity: | 4 x 250 ml |
| Speed: | 500 to 15000 rpm, increasement 100 rpm |
| RCF: | 100 to 21400×g |
| Temperature Range: | -20℃ to +40℃, under room temperature 25℃ |
| Max Speed: | 25000 rpm |
| Max RCF: | 65000 x g |
| Max Capacity: | 4x1000 ml |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 24760 × g |
| Maximum Capacity: | 6 x 100 mL |
| Maximum Speed: | 21000 rpm |
| Maximum RCF: | 47580 × g |
| Maximum Capacity: | 4 × 750 ml |
| Maximum Speed: | 21,000 rpm |
| Maximum RCF: | 31,405 × g |
| Maximum Capacity: | 4 × 750 ml |
| Max Speed: | 16000 rpm |
| Max RCF: | 27520 x g |
| Max Capacity: | 6x500 ml |
| Maximum Speed: | 18,500 rpm |
| Maximum RCF: | 30,025 x g |
| Maximum Capacity: | 4 x 250 ml |
| Max Speed: | 4500 rpm |
| Max RCF: | 3380 x g |
| Max Capacity: | 6 x 50 ml syringe |
| Max Speed: | 4700 rpm |
| Max RCF: | 2000 xg |
| Max Capacity: | 12 x 7 ml (SERO rotor) |
| Maximum Speed: | 4500 rpm (adjustable) |
| Maximum RCF: | 2000 × g (adjustable) |
| Maximum Capacity: | 12 × 2 mL tubes (12 mm × 75 mm) |
| Max Speed: | 4000 rpm |
| Max RCF: | 3400 xg |
| Max Capacity: | 4 x 200 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Max Speed: | 5000 rpm |
| Max RCF: | 5200 × g |
| Max Capacity: | 4 × 800 ml |
| Max Speed: | 8000 rpm |
| Max RCF: | 14500 × g |
| Max Capacity: | 6x2400 ml / 12 blood bags / 384 blood tubes |
| Max Capacity: | 4 tubes, each 1000 ml |
| Max Speed: | 6000 rpm |
| Max RCF: | 6693×g |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123× g |
| Maximum Capacity: | 4x250 ml |
| Maximum Speed Range: | 6000 rpm |
| Maximum RCF: | 6880 × g |
| Maximum Capacity: | 6 × 1000 ml |
| Maximum Speed: | 20000 rpm |
| Maximum RCF: | 27994 × g |
| Maximum Capacity: | 6x100 ml |
| Speed: | 500 to 15000 rpm, increasement 100 rpm |
| Maximum Sample Density: | 1.2g/ml |
| Acceleration/Deceleration : | Ⅰ (≤ 20) <br/> Ⅱ (≤ 40s) <br/> Ⅲ (≤ 60s) |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 21630 × g |
| Maximum Capacity: | 12x5 ml |
| Maximum Speed: | 18000 rpm |
| Maximum RCF: | 24814 × g |
| Maximum Capacity: | 6x100 ml |
| Maximum Speed: | 18500 rpm |
| Maximum RCF: | 24760 × g |
| Maximum Capacity: | 4x500 ml |
| Maximum Speed: | 16,500 rpm |
| Maximum RCF: | 24,814 × g |
| Maximum Capacity: | 6 × 100 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 15093× g |
| Maximum Capacity: | 8x5 ml |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 18262× g |
| Maximum Capacity: | 8x5 ml |
| Speed: | 500 to 15000 rpm, 100 rpm increments |
| RCF: | 100 to 15000×g, 100×g increments |
| Maximum Rotor Radius: | 60 mm |
| Speed Range: | 4000 rpm, 6000 rpm and 7000 rpm, adjustable |
| Maximum RCF: | 960×g, 4000 rpm <br/> 2200×g, 6000 rpm <br/> 2900×g, 7000 rpm |
| Capacity: | 6×1.5 ml/2.0 ml, 6×0.5 ml, 16×0.2 ml centrifuge tube <br/> 2×8×0.2 ml PCR tube strips |
| Speed Range: | 3000 to 10000 rpm |
| Maximum RCF: | 500 to 5400×g |
| Capacity: | 8×2.0ml/1.5ml/0.5ml centrifuge tube <br/> 4×8×0.2ml PCR tube strips |
| Speed Range: | 500 to 15000 rpm |
| RCF Range: | 16 to 15080 g |
| Capacity: | 12 x 1.5 / 2.0ml centrifuge tubes |
| Maximum Speed: | 10000rpm |
| Maximum RCF: | 6100xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml |
| Speed Range: | 500 to 12,000 rpm, 500 rpm increments |
| Maximum RCF: | 9,650 × g |
| Capacity: | 32 × 0.2 ml centrifugal tubes <br/> 12 × 0.5/1.5/2.0 ml centrifugal tubes <br/> 4 × 8 × 0.2 ml PCR strips |
| Maximum Speed: | 6000 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | ≤ 2 seconds |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 2000 g |
| Capacity (Standard): | 8 × 1.5 / 2.0 / 0.5 / 0.2 ml |
| Maximum Speed: | 6000rpm |
| Maximum RCF: | 2200xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Maximum Speed: | 7500rpm |
| Maximum RCF: | 3450xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Maximum Speed: | 2800 rpm |
| Maximum RCF: | 600×g |
| Maximum Rotor Radius: | 63 mm |
| Rotating Speed: | 2200 to 2800 rpm |
| Maximum RCF: | 550 g |
| Capacity: | 2 PCR plates |
| Rotating Speed: | 500 to 2500 rpm |
| RCF Range: | 32 to 797g |
| Capacity: | 2 pcs Microplates or Deep-well plates |
| Maximum Speed: | 2500 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | 15 seconds |
| Maximum Speed: | 3300 rpm |
| Maximum RCF: | 1920 x g |
| Maximum Capacity: | 8 x 30 ml |
| Maximum Speed: | 3840 rpm |
| Maximum RCF: | 1790 xg |
| Maximum Capacity: | 12 Gel card |
| Capacity: | 24 Gel Cards (6 column / 8 column) |
| Speed Range: | 500 to 2200 rpm |
| Timing Range: | 1 min to 30 min |
| Maximum Speed: | 3840 rpm |
| Maximum RCF : | 1790 ×g |
| Capacity : | 24 gel card |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 2170 xg |
| Maximum Capacity: | 10 pcs slide glass |
| Maximum Speed: | 3000 rpm |
| Maximum RCF : | 890 × g |
| Maximum Capacity : | 12 cards |
| Max Speed: | 3500 rpm |
| Max RCF: | 1640 xg |
| Max Capacity: | 12x10 ml |
| Max Speed: | 12000 rpm |
| Max RCF: | 15800 xg |
| Capacity: | 24pcs capillary tube |