High Speed Refrigerated Centrifuge ADHSC-501 operates at a speed of 18000 rpm, providing consistent sample separation. This unit has a touchscreen interface for easy control of speed, temperature, and time. It offers programmable protocols with memory storage for frequently used centrifugation routines. The centrifuge supports various rotors for microplates, tubes, bottles, and swing-buckets. Our High Speed Refrigerated Centrifuge is used in biochemistry, pharmaceuticals and research labs for rapid separation of small particles.
| Max Speed | 18000 rpm |
| Max RCF | 31405 x g |
| Max Capacity | 4 x 250 ml |
| Temperature Range | -20°C to +40°C |
| Temperature Accuracy | ±1°C |
| Speed Accuracy | ±10 rpm |
| Time Setting | 1 s to 99 h 59 m 59 s |
| Noise | ≤ 60 dB(A) |
| Power Consumption | 1800 W |
| Dimension | 680 x 620 x 840 mm |
| Weight | 134 kg |
Our High Speed Refrigerated Centrifuge ADHSC-501 is used in molecular biology, biochemistry and pharmaceutical research for rapid, temperature-controlled separation of biological and chemical samples.
Rotor Type Capacity Max Speed Max RCF Tube size Fixed angle rotor 01 12×1.5/2.2ml 18000rpm 22675×g Φ11×42mm Fixed angle rotor 02 12×5ml 16000rpm 20807×g Φ14×54mm Fixed angle rotor 03 24×1.5/2.2ml 16000rpm 24814×g Φ11×42mm Fixed angle rotor 04 24×1.5/2.2ml 18000rpm 31405×g Φ11×42mm Fixed angle rotor 05 12×10ml 15000rpm 20803×g Φ16×86mm Fixed angle rotor 06 6×50ml round bottom 13000rpm 18440×g Φ29×111mm Fixed angle rotor 07 6×50ml conical bottom 13000rpm 18440×g Φ29×116mm Fixed angle rotor 08 4×100ml 10000rpm 11045×g Φ38×123mm Fixed angle rotor 09 8×50ml round bottom 10000rpm 11045×g Φ29×111mm Fixed angle rotor10 12×15ml conical bottom 12000rpm 15906×g Φ17×121mm Fixed angle rotor 11 6×10ml 16000rpm 19004×g Φ16×86mm Fixed angle rotor 12 8×15ml 14000rpm 17333×g Φ17×121mm Fixed angle rotor 13 12×50ml 10000rpm 14310×g - Microplate rotor 01 2×3×96 well plate 4000rpm 2003×g - Swing out rotor 01 4×250ml 4500rpm 3735×g Φ63×121mm
1. In which laboratory applications is the Low-Speed Centrifuge ADLSC-501 commonly used?
The Low-Speed Centrifuge ADLSC-501 is widely used in clinical labs, educational institutions, research centers, and biotechnology labs. It is especially effective for blood sample separation, serum preparation, urine sedimentation, and low-speed cell harvesting. Its reliability and easy operation make it ideal for routine lab work. This model is also appreciated for its quiet operation and compact design, which saves bench space. Overall, it's a dependable tool for everyday centrifugation needs.
2. What safety features are included in the High Speed Refrigerated Centrifuge ADHSC-501?
The High Speed Refrigerated Centrifuge ADHSC-501 is designed with multiple built-in safety features including lid interlock, imbalance detection, and over-speed protection. The lid remains locked during operation and only opens once the rotor has stopped completely. Imbalance detection prevents damage by automatically stopping the centrifuge if uneven loads are detected. Over-speed protection ensures the rotor does not exceed safe operational limits.
3. Is the High Speed Refrigerated Centrifuge ADHSC-501 easy to operate and program?
Yes, the High Speed Refrigerated Centrifuge ADHSC-501 features a user-friendly touchscreen interface that allows intuitive control over all parameters such as speed, time, temperature, and acceleration/deceleration rates. Users can create and save multiple programs for repeated runs, saving time and improving consistency. Real-time displays show operating status and remaining run time. Its programmable functions reduce manual errors and increase reproducibility. The interface is designed to be accessible even for first-time users.
4. What kind of rotors and accessories are compatible with High Speed Refrigerated Centrifuge ADHSC-501?
The High Speed Refrigerated Centrifuge ADHSC-501 supports a wide range of rotors, including fixed-angle and swing-out rotors, making it compatible with tubes, bottles, microplates, and PCR strips. This flexibility allows it to be used across multiple disciplines such as biotechnology, clinical diagnostics, and pharmaceuticals. Rotors are designed for easy loading and unloading, and many are autoclavable for sterilization. Quick-change rotor systems reduce downtime between procedures.
5. What types of samples can be processed using the High Speed Refrigerated Centrifuge ADHSC-501?
The High Speed Refrigerated Centrifuge ADHSC-501 is suitable for processing a wide variety of biological, chemical, and clinical samples including blood, plasma, serum, DNA/RNA, proteins, cell lysates, and microorganisms. Its high-speed capability and precise temperature control make it ideal for sensitive molecular biology procedures. It’s commonly used in applications such as pelletizing cells, isolating nucleic acids, separating lipoproteins, and purifying viruses. The adaptable rotor system allows for handling of tubes of different sizes and types.
6. How does the High Speed Refrigerated Centrifuge ADHSC-501 ensure temperature stability during operation?
The High Speed Refrigerated Centrifuge ADHSC-501 uses a high-efficiency refrigeration system that actively monitors and adjusts the chamber temperature throughout the spin cycle. This ensures that the internal environment remains within the set temperature range, even during high-speed runs that generate heat. The system automatically compensates for thermal buildup, protecting sample integrity. Pre-cooling functionality allows the chamber to reach the desired temperature before loading samples.
7. What is a High Speed Refrigerated Centrifuge?
A High Speed Refrigerated Centrifuge is a laboratory instrument that combines high rotational speeds with temperature control to efficiently separate biological samples while preserving their integrity. It is essential for processing heat-sensitive samples by preventing thermal degradation during centrifugation. These centrifuges are widely used in molecular biology, clinical diagnostics, and biochemistry labs.
8. Why is refrigeration important in centrifugation?
Refrigeration helps maintain low temperatures during centrifugation, preventing heat buildup that can degrade temperature-sensitive samples like proteins, enzymes, and nucleic acids. It also minimizes enzymatic activity and preserves the biological function and structure of delicate molecules. This ensures accurate and reliable experimental results.
9. Can the High Speed Refrigerated Centrifuge maintain temperature during the entire run?
Yes, the High Speed Refrigerated Centrifuge system continuously cools the rotor chamber to maintain the set temperature throughout the centrifugation process. This ensures that sensitive samples remain stable and protected from heat-induced damage. Consistent temperature control is critical for reproducible and accurate experimental results.
| Maximum Speed | 15,000 rpm |
| Maximum RCF | 21,630 × g |
| Maximum Capacity | 12 × 5 ml |
| Max Speed | 25000 rpm |
| Max RCF | 65000 x g |
| Max Capacity | 4x1000 ml |
| Maximum Speed | 19,000 rpm |
| Maximum RCF | 30,367× g |
| Maximum Capacity | 4 x 500 ml |
| Maximum Speed | 21,000 rpm |
| Maximum RCF | 31,405 × g |
| Maximum Capacity | 4 × 750 ml |
| Max Speed: | 4500 rpm |
| Max RCF: | 3380 x g |
| Max Capacity: | 6 x 50 ml syringe |
| Max Speed: | 4700 rpm |
| Max RCF: | 2000 xg |
| Max Capacity: | 12 x 7 ml (SERO rotor) |
| Max Speed: | 4000 rpm |
| Max RCF: | 3400 xg |
| Max Capacity: | 4 x 200 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Max Speed: | 5000 rpm |
| Max RCF: | 5200 × g |
| Max Capacity: | 4 × 800 ml |
| Max Speed: | 8000 rpm |
| Max RCF: | 14500 × g |
| Max Capacity: | 6x2400 ml / 12 blood bags / 384 blood tubes |
| Maximum Speed Range: | 6000 rpm |
| Maximum RCF: | 6880 × g |
| Maximum Capacity: | 6 × 1000 ml |
| Max Capacity: | 4 tubes, each 1000 ml |
| Max Speed: | 6000 rpm |
| Max RCF: | 6693×g |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123× g |
| Maximum Capacity: | 4x250 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Maximum Speed: | 18500 rpm |
| Maximum RCF: | 24760 × g |
| Maximum Capacity: | 4x500 ml |
| Speed: | 500 to 15000 rpm, increasement 100 rpm |
| Maximum Sample Density: | 1.2g/ml |
| Acceleration/Deceleration : | Ⅰ (≤ 20) <br/> Ⅱ (≤ 40s) <br/> Ⅲ (≤ 60s) |
| Maximum Speed: | 18000 rpm |
| Maximum RCF: | 24814 × g |
| Maximum Capacity: | 6x100 ml |
| Maximum Speed: | 16,500 rpm |
| Maximum RCF: | 24,814 × g |
| Maximum Capacity: | 6 × 100 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 21630 × g |
| Maximum Capacity: | 12x5 ml |
| Maximum Speed: | 20000 rpm |
| Maximum RCF: | 27994 × g |
| Maximum Capacity: | 6x100 ml |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 18262× g |
| Maximum Capacity: | 8x5 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 15093× g |
| Maximum Capacity: | 8x5 ml |
| Speed: | 500 to 15000 rpm, 100 rpm increments |
| RCF: | 100 to 15000×g, 100×g increments |
| Maximum Rotor Radius: | 60 mm |
| Max Speed: | 4200 rpm |
| Max RCF: | 2680 × g |
| Max Capacity: | 4x50ml;12x15ml tube/ blood tube/PRP tube |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5200 × g |
| Maximum Capacity: | 4 × 500 ml |
| Maximum Speed: | 4200 rpm |
| Maximum RCF: | 2680 × g |
| Maximum Capacity: | 24x10ml blood tube |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201x g |
| Maximum Capacity: | 4x800 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 8 × 100 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 4 × 250 ml |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 3580 x g |
| Maximum Capacity: | 4x1000 ml |
| Maximum Speed: | 4200 rpm |
| Maximum RCF: | 3285 × g |
| Maximum Capacity: | 4 × 100 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 6 × 50 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123 × g |
| Maximum Capacity: | 6 × 50 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 5200 × g |
| Maximum Capacity: | 4 × 500 ml |
| Speed Range: | 4000 rpm, 6000 rpm and 7000 rpm, adjustable |
| Maximum RCF: | 960×g, 4000 rpm <br/> 2200×g, 6000 rpm <br/> 2900×g, 7000 rpm |
| Capacity: | 6×1.5 ml/2.0 ml, 6×0.5 ml, 16×0.2 ml centrifuge tube <br/> 2×8×0.2 ml PCR tube strips |
| Maximum Speed: | 6000rpm |
| Maximum RCF: | 2200xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Maximum Speed: | 6000 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | ≤ 2 seconds |
| Maximum Speed: | 7500rpm |
| Maximum RCF: | 3450xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Speed Range: | 500 to 15000 rpm |
| RCF Range: | 16 to 15080 g |
| Capacity: | 12 x 1.5 / 2.0ml centrifuge tubes |
| Speed Range: | 500 to 12,000 rpm, 500 rpm increments |
| Maximum RCF: | 9,650 × g |
| Capacity: | 32 × 0.2 ml centrifugal tubes <br/> 12 × 0.5/1.5/2.0 ml centrifugal tubes <br/> 4 × 8 × 0.2 ml PCR strips |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 2000 g |
| Capacity (Standard): | 8 × 1.5 / 2.0 / 0.5 / 0.2 ml |
| Speed Range: | 3000 to 10000 rpm |
| Maximum RCF: | 500 to 5400×g |
| Capacity: | 8×2.0ml/1.5ml/0.5ml centrifuge tube <br/> 4×8×0.2ml PCR tube strips |
| Maximum Speed: | 10000rpm |
| Maximum RCF: | 6100xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml |
| Rotating Speed: | 2200 to 2800 rpm |
| Maximum RCF: | 550 g |
| Capacity: | 2 PCR plates |
| Maximum Speed: | 2500 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | 15 seconds |
| Rotating Speed: | 500 to 2500 rpm |
| RCF Range: | 32 to 797g |
| Capacity: | 2 pcs Microplates or Deep-well plates |
| Maximum Speed: | 2800 rpm |
| Maximum RCF: | 600×g |
| Maximum Rotor Radius: | 63 mm |
| Maximum Speed: | 3300 rpm |
| Maximum RCF: | 1920 x g |
| Maximum Capacity: | 8 x 30 ml |
| Maximum Speed: | 3840 rpm |
| Maximum RCF: | 1790 xg |
| Maximum Capacity: | 12 Gel card |
| Maximum Speed: | 3840 rpm |
| Maximum RCF : | 1790 ×g |
| Capacity : | 24 gel card |
| Capacity: | 24 Gel Cards (6 column / 8 column) |
| Speed Range: | 500 to 2200 rpm |
| Timing Range: | 1 min to 30 min |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 2170 xg |
| Maximum Capacity: | 10 pcs slide glass |
| Maximum Speed: | 3000 rpm |
| Maximum RCF : | 890 × g |
| Maximum Capacity : | 12 cards |
| Max Speed: | 3500 rpm |
| Max RCF: | 1640 xg |
| Max Capacity: | 12x10 ml |
| Max Speed: | 12000 rpm |
| Max RCF: | 15800 xg |
| Capacity: | 24pcs capillary tube |