Refrigerated Low-Speed Centrifuge ADRLC-504 operates at a speed of 6000 rpm, providing consistent sample separation. The lid lock mechanism prevents accidental opening during operation for enhanced user safety. This unit includes a fast-cooling function, ideal for temperature-sensitive biological samples. It has a powerful refrigeration system for precise low-temperature control during centrifugation. Our Refrigerated Low-Speed Centrifuge is used in clinical, research and biotechnology for temperature-sensitive sample separation.
| Maximum Speed Range | 6000 rpm |
| Maximum RCF | 6880 × g |
| Maximum Capacity | 6 × 1000 ml |
| Temperature Range | -20°C to +40°C |
| Temperature Accuracy | ±1℃ |
| Speed Accuracy | ±10 rpm |
| Time Setting | 1 min to 99 hr 59 min / Pulse |
| Noise | ≤65 dB(A) |
| Power Consumption | 5000 W |
| Dimension | 850 x 730 x 930 mm |
| Weight | 255 kg |
Our Refrigerated Low-Speed Centrifuge ADRLC-504 is widely used in microbiology, molecular biology, veterinary labs for precise separation of temperature-sensitive samples.
Rotor Type Capacity Max Speed Max RCF Tube Size Fixed Angle Rotor 01 6 × 500 ml 6000 rpm 6880 × g Φ74x170mm Swing Out Rotor 01 6 × 1000 ml 4000 rpm 5880 × g Φ100x175mm Swing Out Rotor 02 6 × Blood Bag 4500 rpm 5880 × g - Swing Out Rotor 03 210 × 2-7 ml Blood Tubes 4200 rpm 5180 × g Φ13x75-100mm
Adapters no. Capacity (mL) Adapter 1 6×750 ml Adapter 2 6×500 ml Adapter 3 6×500 ml (conical) Adapter 4 6×250 ml Adapter 5 18×100 ml Adapter 6 30×50 ml Adapter 7 84×15 ml Adapter 8 6×750 ml Adapter 9 6×500 ml Adapter 10 6×250 ml Adapter 11 24×100 ml Adapter 12 42×50 ml Adapter 13 84×15 ml
1. What is the main function of the Refrigerated Low Speed Centrifuge ADRLC-504?
The Refrigerated Low Speed Centrifuge ADRLC-504 is designed to separate components of biological or chemical samples based on density using centrifugal force. Its low-speed operation is ideal for sensitive applications involving cells, blood, or large-volume samples. The built-in refrigeration system maintains consistent temperature to preserve sample integrity. This feature makes it suitable for temperature-sensitive materials during long runs. It ensures both efficiency and protection in laboratory settings.
2. What is the temperature range and control accuracy of the Refrigerated Low Speed Centrifuge ADRLC-504?
The Low Speed Centrifuge ADRLC-504 typically operates within a temperature range of -20°C to +40°C. It offers precise temperature control with minimal fluctuation, often within ±1°C accuracy. This allows users to maintain stable cooling during extended centrifugation. Reliable temperature management is critical for biological and clinical samples. The unit ensures uniform cooling across the chamber to maintain sample quality.
3. Can the Refrigerated Low Speed Centrifuge ADRLC-504 accommodate different types of rotors?
Yes, the Low Speed Centrifuge ADRLC-504 supports multiple rotor types to meet diverse laboratory needs. It can handle swing-out and fixed-angle rotors with varying tube capacities. This versatility allows users to run different sample volumes and container formats. The rotor exchange process is designed to be user-friendly and secure. With compatible adapters, it offers great flexibility for multiple applications.
4. What are the safety features included in the Refrigerated Low Speed Centrifuge ADRLC-504?
The Refrigerated Low Speed Centrifuge ADRLC-504 is equipped with safety features such as imbalance detection, lid lock system, and emergency lid release. The lid remains locked during operation to prevent accidental opening. Imbalance sensors stop the centrifuge if uneven loads are detected. These measures protect both the user and the equipment. It ensures safe and reliable operation in daily lab use.
5. In which applications is the Refrigerated Low Speed Centrifuge ADRLC-504 most commonly used?
The Refrigerated Low Speed Centrifuge ADRLC-504 is widely used in clinical diagnostics, biotechnology, pharmaceuticals, and research laboratories. It is ideal for processing blood, cell cultures, and temperature-sensitive biological samples. Its cooling system makes it suitable for enzyme studies and protein extraction. The centrifuge is especially valuable when preserving molecular integrity is crucial. Its performance and adaptability make it a core tool in many scientific fields.
| Max Capacity | 4 tubes, each 1000 ml |
| Max Speed | 6000 rpm |
| Max RCF | 6693×g |
| Max Speed | 5000 rpm |
| Max RCF | 5200 × g |
| Max Capacity | 4 × 800 ml |
| Maximum Speed | 6000 rpm |
| Maximum RCF | 5201× g |
| Maximum Capacity | 4x750 ml |
| Maximum Speed | 5000 rpm |
| Maximum RCF | 5201× g |
| Maximum Capacity | 4x750 ml |
| Speed: | 500 to 15000 rpm, increasement 100 rpm |
| RCF: | 100 to 21400×g |
| Temperature Range: | -20℃ to +40℃, under room temperature 25℃ |
| Maximum Speed: | 18,500 rpm |
| Maximum RCF: | 30,025 x g |
| Maximum Capacity: | 4 x 250 ml |
| Maximum Speed: | 15,000 rpm |
| Maximum RCF: | 21,630 × g |
| Maximum Capacity: | 12 × 5 ml |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 24760 × g |
| Maximum Capacity: | 6 x 100 mL |
| Max Speed: | 25000 rpm |
| Max RCF: | 65000 x g |
| Max Capacity: | 4x1000 ml |
| Maximum Speed Range: | 14,000 rpm |
| Maximum RCF: | 18,800 × g |
| Maximum Capacity: | 12 × 5 ml |
| Maximum Speed: | 18000 rpm |
| Maximum RCF: | 29684 × g |
| Maximum Capacity: | 6 × 100 ml |
| Max Speed: | 22000 rpm |
| Max RCF: | 33873x g |
| Max Capacity: | 4x750ml |
| Max Speed: | 22000 rpm |
| Max RCF: | 52050 x g |
| Max Capacity: | 6x500 ml |
| Maximum Speed: | 16,500 rpm |
| Maximum RCF: | 24,814 × g |
| Maximum Capacity: | 6 × 100ml |
| Max Speed: | 18000 rpm |
| Max RCF: | 31405 x g |
| Max Capacity: | 4 x 250 ml |
| Max Speed: | 21000 rpm |
| Max RCF: | 47400 x g |
| Max Capacity: | 6x500 ml |
| Max Speed: | 10000 rpm |
| Max RCF: | 18590 x g |
| Max Capacity: | 6x1000 ml |
| Maximum Speed: | 21,000 rpm |
| Maximum RCF: | 31,405 × g |
| Maximum Capacity: | 4 × 750 ml |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 21630 x g |
| Maximum Capacity: | 12 x 10 mL |
| Max Speed: | 16000 rpm |
| Max RCF: | 27520 x g |
| Max Capacity: | 6x500 ml |
| Maximum Speed: | 23,000 rpm |
| Maximum RCF: | 37,023 x g |
| Maximum Capacity: | 4 x 750 ml |
| Maximum Speed: | 19,000 rpm |
| Maximum RCF: | 30,367× g |
| Maximum Capacity: | 4 x 500 ml |
| Maximum Speed: | 22,000 RPM |
| Maximum RCF: | 33,873 × g |
| Maximum Capacity: | 6 × 100 mL |
| Maximum Speed: | 20,000 RPM |
| Maximum RCF: | 31,405 × g |
| Maximum Capacity: | 6 × 100 ml |
| Max Speed: | 4500 rpm |
| Max RCF: | 3380 x g |
| Max Capacity: | 6 x 50 ml syringe |
| Max Speed: | 4700 rpm |
| Max RCF: | 2000 xg |
| Max Capacity: | 12 x 7 ml (SERO rotor) |
| Max Speed: | 4000 rpm |
| Max RCF: | 3400 xg |
| Max Capacity: | 4 x 200 ml |
| Maximum Speed: | 20000 rpm |
| Maximum RCF: | 27994 × g |
| Maximum Capacity: | 6x100 ml |
| Maximum Speed: | 16,500 rpm |
| Maximum RCF: | 24,814 × g |
| Maximum Capacity: | 6 × 100 ml |
| Maximum Speed: | 18000 rpm |
| Maximum RCF: | 24814 × g |
| Maximum Capacity: | 6x100 ml |
| Speed: | 500 to 15000 rpm, increasement 100 rpm |
| Maximum Sample Density: | 1.2g/ml |
| Acceleration/Deceleration : | Ⅰ (≤ 20) <br/> Ⅱ (≤ 40s) <br/> Ⅲ (≤ 60s) |
| Maximum Speed: | 18500 rpm |
| Maximum RCF: | 24760 × g |
| Maximum Capacity: | 4x500 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 21630 × g |
| Maximum Capacity: | 12x5 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 15093× g |
| Maximum Capacity: | 8x5 ml |
| Speed: | 500 to 15000 rpm, 100 rpm increments |
| RCF: | 100 to 15000×g, 100×g increments |
| Maximum Rotor Radius: | 60 mm |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 18262× g |
| Maximum Capacity: | 8x5 ml |
| Max Speed: | 4200 rpm |
| Max RCF: | 2680 × g |
| Max Capacity: | 4x50ml;12x15ml tube/ blood tube/PRP tube |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 3580 x g |
| Maximum Capacity: | 4x1000 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 6 × 50 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 8 × 100 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5200 × g |
| Maximum Capacity: | 4 × 500 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 4 × 250 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201x g |
| Maximum Capacity: | 4x800 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 5200 × g |
| Maximum Capacity: | 4 × 500 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123 × g |
| Maximum Capacity: | 6 × 50 ml |
| Maximum Speed: | 4200 rpm |
| Maximum RCF: | 3285 × g |
| Maximum Capacity: | 4 × 100 ml |
| Maximum Speed: | 4200 rpm |
| Maximum RCF: | 2680 × g |
| Maximum Capacity: | 24x10ml blood tube |
| Maximum Speed: | 7500rpm |
| Maximum RCF: | 3450xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Maximum Speed: | 6000 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | ≤ 2 seconds |
| Speed Range: | 500 to 15000 rpm |
| RCF Range: | 16 to 15080 g |
| Capacity: | 12 x 1.5 / 2.0ml centrifuge tubes |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 2000 g |
| Capacity (Standard): | 8 × 1.5 / 2.0 / 0.5 / 0.2 ml |
| Maximum Speed: | 10000rpm |
| Maximum RCF: | 6100xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml |
| Speed Range: | 4000 rpm, 6000 rpm and 7000 rpm, adjustable |
| Maximum RCF: | 960×g, 4000 rpm <br/> 2200×g, 6000 rpm <br/> 2900×g, 7000 rpm |
| Capacity: | 6×1.5 ml/2.0 ml, 6×0.5 ml, 16×0.2 ml centrifuge tube <br/> 2×8×0.2 ml PCR tube strips |
| Speed Range: | 500 to 12,000 rpm, 500 rpm increments |
| Maximum RCF: | 9,650 × g |
| Capacity: | 32 × 0.2 ml centrifugal tubes <br/> 12 × 0.5/1.5/2.0 ml centrifugal tubes <br/> 4 × 8 × 0.2 ml PCR strips |
| Speed Range: | 3000 to 10000 rpm |
| Maximum RCF: | 500 to 5400×g |
| Capacity: | 8×2.0ml/1.5ml/0.5ml centrifuge tube <br/> 4×8×0.2ml PCR tube strips |
| Maximum Speed: | 6000rpm |
| Maximum RCF: | 2200xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Rotating Speed: | 500 to 2500 rpm |
| RCF Range: | 32 to 797g |
| Capacity: | 2 pcs Microplates or Deep-well plates |
| Maximum Speed: | 2800 rpm |
| Maximum RCF: | 600×g |
| Maximum Rotor Radius: | 63 mm |
| Rotating Speed: | 2200 to 2800 rpm |
| Maximum RCF: | 550 g |
| Capacity: | 2 PCR plates |
| Maximum Speed: | 2500 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | 15 seconds |
| Maximum Speed: | 3300 rpm |
| Maximum RCF: | 1920 x g |
| Maximum Capacity: | 8 x 30 ml |
| Maximum Speed: | 3840 rpm |
| Maximum RCF: | 1790 xg |
| Maximum Capacity: | 12 Gel card |
| Capacity: | 24 Gel Cards (6 column / 8 column) |
| Speed Range: | 500 to 2200 rpm |
| Timing Range: | 1 min to 30 min |
| Maximum Speed: | 3840 rpm |
| Maximum RCF : | 1790 ×g |
| Capacity : | 24 gel card |
| Maximum Speed: | 3000 rpm |
| Maximum RCF : | 890 × g |
| Maximum Capacity : | 12 cards |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 2170 xg |
| Maximum Capacity: | 10 pcs slide glass |
| Max Speed: | 3500 rpm |
| Max RCF: | 1640 xg |
| Max Capacity: | 12x10 ml |
| Max Speed: | 12000 rpm |
| Max RCF: | 15800 xg |
| Capacity: | 24pcs capillary tube |