| Maximum Speed | 2500 rpm ±5% |
| Rotation Direction | Anticlockwise (fixed direction) |
| Acceleration Time | 15 seconds |
| Braking Time | < 2 seconds |
| RCF | 480 ×g |
| Rotor Type | Angle Rotor |
| Rotor Capacity | 2 × 96 PCR plates |
| Motor Type | DC brushless motor with low-noise ball bearing |
| Electrical Safety Standard | IEC 61010-2-020 compliant |
| Power Supply | AC 110 to 250V, 50/60 Hz |
| Product Dimensions (L × W × H) | 345 × 289 × 168 mm |
| Packaging Dimensions (L × W × H) | 365 × 310 × 218 mm |
| Net Weight | 6.5 kg |
| Gross Weight | 7.2 kg |
Microplate Centrifuge ADMPC-502 is specifically engineered to boost the efficiency and precision of PCR procedures, ensuring consistent, reliable, and high-quality results in laboratory settings.
1. What is the speed and accuracy of the Microplate Centrifuge ADMPC-502?
The Microplate Centrifuge ADMPC-502 delivers a top speed of 2500 rpm with ±5% precision, ensuring consistent and reliable sample separation. This high level of accuracy supports repeatable results, making it suitable for sensitive lab applications. It maintains stable rotation throughout each run, minimizing variability and enhancing performance reliability.
2. What types of tubes and plates are compatible with this Microplate Centrifuge ADMPC-502?
Microplate Centrifuge ADMPC-502 is designed to accommodate various formats including flat tubes, strip tubes, and complete microplates. Its flexible rotor system allows users to perform multiple protocols without needing different equipment. This makes it a versatile choice for molecular biology and diagnostic labs.
3. How does the Microplate Centrifuge ADMPC-502 ensure user and sample safety?
Microplate Centrifuge ADMPC-502 includes an open-lid protection mechanism that instantly halts rotor movement when the lid is lifted during operation. This feature prevents sample spills and potential injury. The built-in safety ensures both user confidence and sample integrity during every cycle.
4. What is the benefit of its fixed anticlockwise rotation in Microplate Centrifuge ADMPC-502?
The anticlockwise spinning maintains uniform distribution of force across all wells, ensuring equal treatment of each sample. This design supports accurate results, especially in high throughput and PCR workflows. It simplifies use by removing the need for directional adjustment.
5. What makes Microplate Centrifuge ADMPC-502 efficient for daily lab operations?
Quick acceleration and one-button operation allow for fast processing without complex setup. Its compact size saves space, while quiet operation reduces noise in busy lab environments. Durable construction ensures long-term use with minimal maintenance.
6. What is a Microplate Centrifuge used for?
A Microplate Centrifuge is used to spin and separate samples contained within microplates, such as 96- or 384-well plates, for applications like PCR, ELISA, and cell culture assays. It helps to quickly collect all liquids at the bottom of wells, reducing sample loss and improving assay accuracy. This makes it essential for high-throughput laboratories requiring fast and reliable sample processing.
7. What is imbalance detection and why is it important in Microplate Centrifuges?
Imbalance detection in a Microplate Centrifuge automatically stops the device if the load is uneven, protecting the centrifuge and ensuring user safety. This feature prevents damage to the motor and rotor caused by excessive vibrations. It also helps maintain accurate and consistent sample processing by avoiding disruptions during the spin cycle.
| Rotating Speed | 500 to 2500 rpm |
| RCF Range | 32 to 797g |
| Capacity | 2 pcs Microplates or Deep-well plates |
| Maximum Speed | 2800 rpm |
| Maximum RCF | 600×g |
| Maximum Rotor Radius | 63 mm |
| Rotating Speed | 2200 to 2800 rpm |
| Maximum RCF | 550 g |
| Capacity | 2 PCR plates |
| Maximum Speed: | 15,000 rpm |
| Maximum RCF: | 21,630 × g |
| Maximum Capacity: | 12 × 5 ml |
| Maximum Speed: | 20,000 RPM |
| Maximum RCF: | 31,405 × g |
| Maximum Capacity: | 6 × 100 ml |
| Maximum Speed: | 21,000 rpm |
| Maximum RCF: | 31,405 × g |
| Maximum Capacity: | 4 × 750 ml |
| Max Speed: | 10000 rpm |
| Max RCF: | 18590 x g |
| Max Capacity: | 6x1000 ml |
| Max Speed: | 21000 rpm |
| Max RCF: | 47400 x g |
| Max Capacity: | 6x500 ml |
| Maximum Speed Range: | 14,000 rpm |
| Maximum RCF: | 18,800 × g |
| Maximum Capacity: | 12 × 5 ml |
| Max Speed: | 16000 rpm |
| Max RCF: | 27520 x g |
| Max Capacity: | 6x500 ml |
| Maximum Speed: | 30000 rpm |
| Maximum RCF: | 65000 × g |
| Maximum Capacity: | 4×1000ml |
| Maximum Speed: | 16,500 rpm |
| Maximum RCF: | 24,814 × g |
| Maximum Capacity: | 6 × 100ml |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 24760 × g |
| Maximum Capacity: | 6 x 100 mL |
| Maximum Speed: | 18,500 rpm |
| Maximum RCF: | 30,025 x g |
| Maximum Capacity: | 4 x 250 ml |
| Speed: | 500 to 15000 rpm, increasement 100 rpm |
| RCF: | 100 to 21400×g |
| Temperature Range: | -20℃ to +40℃, under room temperature 25℃ |
| Max Speed: | 18000 rpm |
| Max RCF: | 31405 x g |
| Max Capacity: | 4 x 250 ml |
| Maximum Speed: | 21000 rpm |
| Maximum RCF: | 47580 × g |
| Maximum Capacity: | 4 × 750 ml |
| Maximum Speed: | 18000 rpm |
| Maximum RCF: | 29684 × g |
| Maximum Capacity: | 6 × 100 ml |
| Maximum Speed: | 22,000 RPM |
| Maximum RCF: | 33,873 × g |
| Maximum Capacity: | 6 × 100 mL |
| Maximum Speed: | 23,000 rpm |
| Maximum RCF: | 37,023 x g |
| Maximum Capacity: | 4 x 750 ml |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 21630 x g |
| Maximum Capacity: | 12 x 10 mL |
| Max Speed: | 22000 rpm |
| Max RCF: | 33873x g |
| Max Capacity: | 4x750ml |
| Maximum Speed: | 19,000 rpm |
| Maximum RCF: | 30,367× g |
| Maximum Capacity: | 4 x 500 ml |
| Max Speed: | 25000 rpm |
| Max RCF: | 65000 x g |
| Max Capacity: | 4x1000 ml |
| Max Speed: | 22000 rpm |
| Max RCF: | 52050 x g |
| Max Capacity: | 6x500 ml |
| Max Speed: | 4500 rpm |
| Max RCF: | 3380 x g |
| Max Capacity: | 6 x 50 ml syringe |
| Maximum Speed: | 4500 rpm (adjustable) |
| Maximum RCF: | 2000 × g (adjustable) |
| Maximum Capacity: | 12 × 2 mL tubes (12 mm × 75 mm) |
| Max Speed: | 4700 rpm |
| Max RCF: | 2000 xg |
| Max Capacity: | 12 x 7 ml (SERO rotor) |
| Max Speed: | 4000 rpm |
| Max RCF: | 3400 xg |
| Max Capacity: | 4 x 200 ml |
| Max Capacity: | 4 tubes, each 1000 ml |
| Max Speed: | 6000 rpm |
| Max RCF: | 6693×g |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123× g |
| Maximum Capacity: | 4x250 ml |
| Maximum Speed Range: | 6000 rpm |
| Maximum RCF: | 6880 × g |
| Maximum Capacity: | 6 × 1000 ml |
| Max Speed: | 5000 rpm |
| Max RCF: | 5200 × g |
| Max Capacity: | 4 × 800 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Max Speed: | 8000 rpm |
| Max RCF: | 14500 × g |
| Max Capacity: | 6x2400 ml / 12 blood bags / 384 blood tubes |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Maximum Speed: | 20000 rpm |
| Maximum RCF: | 27994 × g |
| Maximum Capacity: | 6x100 ml |
| Speed: | 500 to 15000 rpm, increasement 100 rpm |
| Maximum Sample Density: | 1.2g/ml |
| Acceleration/Deceleration : | Ⅰ (≤ 20) <br/> Ⅱ (≤ 40s) <br/> Ⅲ (≤ 60s) |
| Maximum Speed: | 16,500 rpm |
| Maximum RCF: | 24,814 × g |
| Maximum Capacity: | 6 × 100 ml |
| Maximum Speed: | 18500 rpm |
| Maximum RCF: | 24760 × g |
| Maximum Capacity: | 4x500 ml |
| Maximum Speed: | 18000 rpm |
| Maximum RCF: | 24814 × g |
| Maximum Capacity: | 6x100 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 21630 × g |
| Maximum Capacity: | 12x5 ml |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 18262× g |
| Maximum Capacity: | 8x5 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 15093× g |
| Maximum Capacity: | 8x5 ml |
| Speed: | 500 to 15000 rpm, 100 rpm increments |
| RCF: | 100 to 15000×g, 100×g increments |
| Maximum Rotor Radius: | 60 mm |
| Max Speed: | 4200 rpm |
| Max RCF: | 2680 × g |
| Max Capacity: | 4x50ml;12x15ml tube/ blood tube/PRP tube |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4499 x g |
| Maximum Capacity: | 4 x 600ml |
| Maximum Speed: | 4200 rpm |
| Maximum RCF: | 2680 × g |
| Maximum Capacity: | 24x10ml blood tube |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123 × g |
| Maximum Capacity: | 6 × 50 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201x g |
| Maximum Capacity: | 4x800 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 4 × 250 ml |
| Maximum Speed: | 4200 rpm |
| Maximum RCF: | 3285 × g |
| Maximum Capacity: | 4 × 100 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 8 × 100 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5200 × g |
| Maximum Capacity: | 4 × 500 ml |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 3580 x g |
| Maximum Capacity: | 4x1000 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 6 × 50 ml |
| Speed Range: | 4000 rpm, 6000 rpm and 7000 rpm, adjustable |
| Maximum RCF: | 960×g, 4000 rpm <br/> 2200×g, 6000 rpm <br/> 2900×g, 7000 rpm |
| Capacity: | 6×1.5 ml/2.0 ml, 6×0.5 ml, 16×0.2 ml centrifuge tube <br/> 2×8×0.2 ml PCR tube strips |
| Maximum Speed: | 6000rpm |
| Maximum RCF: | 2200xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Speed Range: | 500 to 15000 rpm |
| RCF Range: | 16 to 15080 g |
| Capacity: | 12 x 1.5 / 2.0ml centrifuge tubes |
| Speed Range: | 3000 to 10000 rpm |
| Maximum RCF: | 500 to 5400×g |
| Capacity: | 8×2.0ml/1.5ml/0.5ml centrifuge tube <br/> 4×8×0.2ml PCR tube strips |
| Maximum Speed: | 10000rpm |
| Maximum RCF: | 6100xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml |
| Maximum Speed: | 7500rpm |
| Maximum RCF: | 3450xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 2000 g |
| Capacity (Standard): | 8 × 1.5 / 2.0 / 0.5 / 0.2 ml |
| Maximum Speed: | 6000 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | ≤ 2 seconds |
| Speed Range: | 500 to 12,000 rpm, 500 rpm increments |
| Maximum RCF: | 9,650 × g |
| Capacity: | 32 × 0.2 ml centrifugal tubes <br/> 12 × 0.5/1.5/2.0 ml centrifugal tubes <br/> 4 × 8 × 0.2 ml PCR strips |
| Maximum Speed: | 3300 rpm |
| Maximum RCF: | 1920 x g |
| Maximum Capacity: | 8 x 30 ml |
| Capacity: | 24 Gel Cards (6 column / 8 column) |
| Speed Range: | 500 to 2200 rpm |
| Timing Range: | 1 min to 30 min |
| Maximum Speed: | 3840 rpm |
| Maximum RCF : | 1790 ×g |
| Capacity : | 24 gel card |
| Maximum Speed: | 3840 rpm |
| Maximum RCF: | 1790 xg |
| Maximum Capacity: | 12 Gel card |
| Maximum Speed: | 3000 rpm |
| Maximum RCF : | 890 × g |
| Maximum Capacity : | 12 cards |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 2170 xg |
| Maximum Capacity: | 10 pcs slide glass |
| Max Speed: | 3500 rpm |
| Max RCF: | 1640 xg |
| Max Capacity: | 12x10 ml |
| Max Speed: | 12000 rpm |
| Max RCF: | 15800 xg |
| Capacity: | 24pcs capillary tube |