| Maximum Speed | 5000 rpm |
| Maximum RCF | 4650 × g |
| Maximum Capacity | 6 × 50 ml |
| Speed Accuracy | ±10 rpm |
| Time Setting | 1 s to 99 h 59 m 59 s |
| Acceleration/Deceleration Rate | 40 rates |
| Noise | ≤60 dB(A) |
| Power Consumption | 500 W |
| Dimensions(L×B×H) | 495 x 400 x 420 mm |
| Weight | 27 kg |
Our Low-Speed Centrifuge ADLSC-501 is used in clinical diagnostics, educational laboratories and blood separation for routine sample separation and sedimentation processes.
Rotor | Capacity | Maximum Speed | Maximum RCF | Tube Size |
Fixed angle rotor 01 | 12 x 15 ml | 5000 rpm | 3558 x g | 17x121mm |
Fixed angle rotor 02 | 6 x 50 ml | 5000 rpm | 3558 x g | 29x116mm |
Swing Out Rotor 01 | 24 x 7 ml blood tube | 5000 rpm | 4650 x g | 13x75-100mm |
Swing Out Rotor 02 | 16 x 15 ml | 5000 rpm | 4620 x g | 17x121mm |
Swing Out Rotor 03 | 8 x 15 ml | 5000 rpm | 4620 x g | 17x121mm |
Swing Out Rotor 04 | 4 x 50 ml | 4000 rpm | 2976 x g | 29x116mm |
1. What types of tubes or rotors are compatible with Low-Speed Centrifuge ADLSC-501?
The Low-Speed Centrifuge ADLSC-501 offers a maximum speed of around 5000 RPM, suitable for routine separation tasks in laboratories. It typically supports a maximum capacity of up to 6 × 50 ml or equivalent depending on the rotor used. This makes it ideal for blood separation, sample clarification, and other low-speed applications. The unit is designed for efficiency and safety, balancing performance with quiet operation. Always refer to the rotor chart to ensure optimal load balancing.
2. Does the Low-Speed Centrifuge ADLSC-501 come with safety features?
Yes, the centrifuge includes essential safety mechanisms like lid lock, imbalance detection, and auto-stop during malfunction. These features protect both the user and the equipment. The lid remains locked during operation and only unlocks once the rotor has fully stopped. Imbalance detection ensures safe spinning by halting the process if loads are uneven. These built-in features enhance reliability and minimize accident risks.
3. What are the main applications of Low-Speed Centrifuge ADLSC-501?
The Low-Speed Centrifuge ADLSC-501 is widely used in clinical, research, educational, and industrial labs. It is ideal for blood separation, cell culture processing, urine analysis, and sample clarification. The low-speed design makes it suitable for handling sensitive biological samples without causing damage. It is also employed in biotechnology, microbiology, and diagnostic labs. Its broad utility ensures consistent performance across various laboratory workflows.
4. What is the maximum speed and capacity of the Low-Speed Centrifuge ADLSC-501?
The Low-Speed Centrifuge ADLSC-501 offers a maximum speed of around 5000 RPM, suitable for routine separation tasks in laboratories. It typically supports a maximum capacity of up to 4×100ml or equivalent depending on the rotor used. This makes it ideal for blood separation, sample clarification, and other low-speed applications. The unit is designed for efficiency and safety, balancing performance with quiet operation. Always refer to the rotor chart to ensure optimal load balancing.
5. Can the speed and time be adjusted on the Low-Speed Centrifuge ADLSC-501?
Yes, the Low-Speed Centrifuge ADLSC-501 comes with a user-friendly control panel that allows precise setting of both speed (in RPM) and timer. Speed can typically be adjusted in small increments for different sample requirements. The timer function enables users to set spin durations for consistent and repeatable results. Some models also display RCF (Relative Centrifugal Force) values for accuracy. This flexibility makes the centrifuge suitable for a variety of applications.
6. What is a Low Speed Centrifuge used for?
A Low Speed Centrifuge is primarily used for the separation of biological samples like blood, urine, or cells at lower speeds. Low Speed Centrifuge machines are ideal for routine separation tasks in clinical and research laboratories.
7. Can I use a Low Speed Centrifuge for blood sample separation?
Yes, a Low Speed Centrifuge is commonly used for separating blood components like plasma and serum. The gentle speed of a Low Speed Centrifuge ensures that blood cells are not damaged during the process.
8. What types of tubes are compatible with a Low Speed Centrifuge?
A Low Speed Centrifuge is compatible with various tube types such as conical, round-bottom, and standard test tubes. Always ensure that the tubes used in the Low Speed Centrifuge are balanced properly.
| Maximum Speed | 5000 rpm |
| Maximum RCF | 4650 × g |
| Maximum Capacity | 8 × 100 ml |
| Maximum Speed | 5000 rpm |
| Maximum RCF | 4499 x g |
| Maximum Capacity | 4 x 600ml |
| Maximum Speed | 4000 rpm |
| Maximum RCF | 3580 x g |
| Maximum Capacity | 4x1000 ml |
| Maximum Speed | 6000 rpm |
| Maximum RCF | 5123 × g |
| Maximum Capacity | 6 × 50 ml |
| Maximum Speed: | 23,000 rpm |
| Maximum RCF: | 37,023 x g |
| Maximum Capacity: | 4 x 750 ml |
| Maximum Speed: | 21000 rpm |
| Maximum RCF: | 47580 × g |
| Maximum Capacity: | 4 × 750 ml |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 21630 x g |
| Maximum Capacity: | 12 x 10 mL |
| Maximum Speed: | 18000 rpm |
| Maximum RCF: | 29684 × g |
| Maximum Capacity: | 6 × 100 ml |
| Maximum Speed: | 20,000 RPM |
| Maximum RCF: | 31,405 × g |
| Maximum Capacity: | 6 × 100 ml |
| Maximum Speed: | 30000 rpm |
| Maximum RCF: | 65000 × g |
| Maximum Capacity: | 4×1000ml |
| Max Speed: | 21000 rpm |
| Max RCF: | 47400 x g |
| Max Capacity: | 6x500 ml |
| Max Speed: | 16000 rpm |
| Max RCF: | 27520 x g |
| Max Capacity: | 6x500 ml |
| Maximum Speed: | 16,500 rpm |
| Maximum RCF: | 24,814 × g |
| Maximum Capacity: | 6 × 100ml |
| Max Speed: | 10000 rpm |
| Max RCF: | 18590 x g |
| Max Capacity: | 6x1000 ml |
| Max Speed: | 25000 rpm |
| Max RCF: | 65000 x g |
| Max Capacity: | 4x1000 ml |
| Maximum Speed Range: | 14,000 rpm |
| Maximum RCF: | 18,800 × g |
| Maximum Capacity: | 12 × 5 ml |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 24760 × g |
| Maximum Capacity: | 6 x 100 mL |
| Maximum Speed: | 22,000 RPM |
| Maximum RCF: | 33,873 × g |
| Maximum Capacity: | 6 × 100 mL |
| Maximum Speed: | 19,000 rpm |
| Maximum RCF: | 30,367× g |
| Maximum Capacity: | 4 x 500 ml |
| Max Speed: | 18000 rpm |
| Max RCF: | 31405 x g |
| Max Capacity: | 4 x 250 ml |
| Speed: | 500 to 15000 rpm, increasement 100 rpm |
| RCF: | 100 to 21400×g |
| Temperature Range: | -20℃ to +40℃, under room temperature 25℃ |
| Maximum Speed: | 15,000 rpm |
| Maximum RCF: | 21,630 × g |
| Maximum Capacity: | 12 × 5 ml |
| Max Speed: | 22000 rpm |
| Max RCF: | 33873x g |
| Max Capacity: | 4x750ml |
| Maximum Speed: | 18,500 rpm |
| Maximum RCF: | 30,025 x g |
| Maximum Capacity: | 4 x 250 ml |
| Max Speed: | 22000 rpm |
| Max RCF: | 52050 x g |
| Max Capacity: | 6x500 ml |
| Maximum Speed: | 21,000 rpm |
| Maximum RCF: | 31,405 × g |
| Maximum Capacity: | 4 × 750 ml |
| Max Speed: | 4500 rpm |
| Max RCF: | 3380 x g |
| Max Capacity: | 6 x 50 ml syringe |
| Max Speed: | 4700 rpm |
| Max RCF: | 2000 xg |
| Max Capacity: | 12 x 7 ml (SERO rotor) |
| Maximum Speed: | 4500 rpm (adjustable) |
| Maximum RCF: | 2000 × g (adjustable) |
| Maximum Capacity: | 12 × 2 mL tubes (12 mm × 75 mm) |
| Max Speed: | 4000 rpm |
| Max RCF: | 3400 xg |
| Max Capacity: | 4 x 200 ml |
| Max Speed: | 5000 rpm |
| Max RCF: | 5200 × g |
| Max Capacity: | 4 × 800 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Maximum Speed Range: | 6000 rpm |
| Maximum RCF: | 6880 × g |
| Maximum Capacity: | 6 × 1000 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123× g |
| Maximum Capacity: | 4x250 ml |
| Max Speed: | 8000 rpm |
| Max RCF: | 14500 × g |
| Max Capacity: | 6x2400 ml / 12 blood bags / 384 blood tubes |
| Max Capacity: | 4 tubes, each 1000 ml |
| Max Speed: | 6000 rpm |
| Max RCF: | 6693×g |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 21630 × g |
| Maximum Capacity: | 12x5 ml |
| Speed: | 500 to 15000 rpm, increasement 100 rpm |
| Maximum Sample Density: | 1.2g/ml |
| Acceleration/Deceleration : | Ⅰ (≤ 20) <br/> Ⅱ (≤ 40s) <br/> Ⅲ (≤ 60s) |
| Maximum Speed: | 18000 rpm |
| Maximum RCF: | 24814 × g |
| Maximum Capacity: | 6x100 ml |
| Maximum Speed: | 18500 rpm |
| Maximum RCF: | 24760 × g |
| Maximum Capacity: | 4x500 ml |
| Maximum Speed: | 20000 rpm |
| Maximum RCF: | 27994 × g |
| Maximum Capacity: | 6x100 ml |
| Maximum Speed: | 16,500 rpm |
| Maximum RCF: | 24,814 × g |
| Maximum Capacity: | 6 × 100 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 15093× g |
| Maximum Capacity: | 8x5 ml |
| Speed: | 500 to 15000 rpm, 100 rpm increments |
| RCF: | 100 to 15000×g, 100×g increments |
| Maximum Rotor Radius: | 60 mm |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 18262× g |
| Maximum Capacity: | 8x5 ml |
| Speed Range: | 3000 to 10000 rpm |
| Maximum RCF: | 500 to 5400×g |
| Capacity: | 8×2.0ml/1.5ml/0.5ml centrifuge tube <br/> 4×8×0.2ml PCR tube strips |
| Maximum Speed: | 6000rpm |
| Maximum RCF: | 2200xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Maximum Speed: | 10000rpm |
| Maximum RCF: | 6100xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml |
| Speed Range: | 500 to 15000 rpm |
| RCF Range: | 16 to 15080 g |
| Capacity: | 12 x 1.5 / 2.0ml centrifuge tubes |
| Speed Range: | 4000 rpm, 6000 rpm and 7000 rpm, adjustable |
| Maximum RCF: | 960×g, 4000 rpm <br/> 2200×g, 6000 rpm <br/> 2900×g, 7000 rpm |
| Capacity: | 6×1.5 ml/2.0 ml, 6×0.5 ml, 16×0.2 ml centrifuge tube <br/> 2×8×0.2 ml PCR tube strips |
| Maximum Speed: | 7500rpm |
| Maximum RCF: | 3450xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 2000 g |
| Capacity (Standard): | 8 × 1.5 / 2.0 / 0.5 / 0.2 ml |
| Maximum Speed: | 6000 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | ≤ 2 seconds |
| Speed Range: | 500 to 12,000 rpm, 500 rpm increments |
| Maximum RCF: | 9,650 × g |
| Capacity: | 32 × 0.2 ml centrifugal tubes <br/> 12 × 0.5/1.5/2.0 ml centrifugal tubes <br/> 4 × 8 × 0.2 ml PCR strips |
| Rotating Speed: | 500 to 2500 rpm |
| RCF Range: | 32 to 797g |
| Capacity: | 2 pcs Microplates or Deep-well plates |
| Rotating Speed: | 2200 to 2800 rpm |
| Maximum RCF: | 550 g |
| Capacity: | 2 PCR plates |
| Maximum Speed: | 2500 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | 15 seconds |
| Maximum Speed: | 2800 rpm |
| Maximum RCF: | 600×g |
| Maximum Rotor Radius: | 63 mm |
| Maximum Speed: | 3300 rpm |
| Maximum RCF: | 1920 x g |
| Maximum Capacity: | 8 x 30 ml |
| Maximum Speed: | 3840 rpm |
| Maximum RCF: | 1790 xg |
| Maximum Capacity: | 12 Gel card |
| Capacity: | 24 Gel Cards (6 column / 8 column) |
| Speed Range: | 500 to 2200 rpm |
| Timing Range: | 1 min to 30 min |
| Maximum Speed: | 3840 rpm |
| Maximum RCF : | 1790 ×g |
| Capacity : | 24 gel card |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 2170 xg |
| Maximum Capacity: | 10 pcs slide glass |
| Maximum Speed: | 3000 rpm |
| Maximum RCF : | 890 × g |
| Maximum Capacity : | 12 cards |
| Max Speed: | 3500 rpm |
| Max RCF: | 1640 xg |
| Max Capacity: | 12x10 ml |
| Max Speed: | 12000 rpm |
| Max RCF: | 15800 xg |
| Capacity: | 24pcs capillary tube |