| Rotating Speed | 2200 to 2800 rpm |
| Maximum RCF | 550 g |
| Capacity | 2 PCR plates |
| Time Range | 15sec to 1min59sec |
| Acceleration Time | ≤ 10sec (from 0 to 2800rpm) |
| Brake Time | ≤ 4sec (from 2800rpm to 0) |
| Auto Stop on Lid Opening | Yes |
| Short Run | Yes |
| Fuse | 250V / 3A Ф5×20 |
| Voltage | AC110 to 220V / 50/60 Hz |
| Power Supply | 45W |
| Dimension (L × W × H) | 260 x 240 x 226 mm |
| Net Weight | 3.3 kg |
Microplate Centrifuge ADMPC-503 is used to quickly spin down samples in PCR plates, helping to collect liquids at the bottom of the wells. It is ideal for preparing samples before and after thermal cycling in molecular biology and diagnostic workflows.
1. What is the use of Microplate Centrifuge ADMPC-503?
Microplate Centrifuge ADMPC-503 is primarily used to quickly spin down samples in PCR plates, ensuring that liquids are collected at the bottom of the wells. This is essential before or after thermal cycling in PCR processes. It helps eliminate bubbles and ensures even distribution of reagents. This unit is widely used in molecular biology and clinical diagnostics labs.
2. Can Microplate Centrifuge ADMPC-503 be used with different types of PCR plates?
Microplate Centrifuge ADMPC-503 is compatible with various PCR plate types. These typically include skirted, semi-skirted, and non-skirted plates. However, deep-well plates are usually not supported due to size and balance limitations.
3. Is the Microplate Centrifuge ADMPC-503 easy to operate?
Microplate Centrifuge ADMPC-503 is designed for ease of use, often featuring simple touch-button controls and digital displays. Users can easily set spin time and monitor progress in real-time. It has a countdown timer and auto-stop functions for convenience. Minimal training is required, making it accessible for routine lab work.
4. What is the maximum RCF of the Microplate Centrifuge ADMPC-503?
The maximum Relative Centrifugal Force (RCF) of the Microplate Centrifuge ADMPC-503 is 550 g. This level of force is sufficient to quickly settle samples in PCR plates. It ensures efficient separation without damaging sensitive biological materials. The RCF value is optimized for routine molecular biology applications.
5. Can the Microplate Centrifuge ADMPC-503 be used for short runs?
Microplate Centrifuge ADMPC-503 is ideal for short spin durations. It quickly collects liquid at the bottom of PCR wells within seconds. Users can set brief spin times using the countdown timer for rapid processing. This makes it perfect for quick sample prep between PCR steps.
6. What is a Microplate Centrifuge used for?
A Microplate Centrifuge is used to spin and separate samples contained within microplates, such as 96- or 384-well plates, for applications like PCR, ELISA, and cell culture assays. It helps to quickly collect all liquids at the bottom of wells, reducing sample loss and improving assay accuracy. This makes it essential for high-throughput laboratories requiring fast and reliable sample processing.
7. What is imbalance detection and why is it important in Microplate Centrifuges?
Imbalance detection in a Microplate Centrifuge automatically stops the device if the load is uneven, protecting the centrifuge and ensuring user safety. This feature prevents damage to the motor and rotor caused by excessive vibrations. It also helps maintain accurate and consistent sample processing by avoiding disruptions during the spin cycle.
| Maximum Speed | 2800 rpm |
| Maximum RCF | 600×g |
| Maximum Rotor Radius | 63 mm |
| Maximum Speed | 2500 rpm ±5% |
| Rotation Direction | Anticlockwise (fixed direction) |
| Acceleration Time | 15 seconds |
| Rotating Speed | 500 to 2500 rpm |
| RCF Range | 32 to 797g |
| Capacity | 2 pcs Microplates or Deep-well plates |
| Max Speed: | 21000 rpm |
| Max RCF: | 47400 x g |
| Max Capacity: | 6x500 ml |
| Maximum Speed: | 23,000 rpm |
| Maximum RCF: | 37,023 x g |
| Maximum Capacity: | 4 x 750 ml |
| Max Speed: | 22000 rpm |
| Max RCF: | 33873x g |
| Max Capacity: | 4x750ml |
| Maximum Speed: | 30000 rpm |
| Maximum RCF: | 65000 × g |
| Maximum Capacity: | 4×1000ml |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 24760 × g |
| Maximum Capacity: | 6 x 100 mL |
| Maximum Speed Range: | 14,000 rpm |
| Maximum RCF: | 18,800 × g |
| Maximum Capacity: | 12 × 5 ml |
| Maximum Speed: | 21000 rpm |
| Maximum RCF: | 47580 × g |
| Maximum Capacity: | 4 × 750 ml |
| Maximum Speed: | 15,000 rpm |
| Maximum RCF: | 21,630 × g |
| Maximum Capacity: | 12 × 5 ml |
| Max Speed: | 22000 rpm |
| Max RCF: | 52050 x g |
| Max Capacity: | 6x500 ml |
| Maximum Speed: | 18,500 rpm |
| Maximum RCF: | 30,025 x g |
| Maximum Capacity: | 4 x 250 ml |
| Maximum Speed: | 20,000 RPM |
| Maximum RCF: | 31,405 × g |
| Maximum Capacity: | 6 × 100 ml |
| Maximum Speed: | 16,500 rpm |
| Maximum RCF: | 24,814 × g |
| Maximum Capacity: | 6 × 100ml |
| Maximum Speed: | 19,000 rpm |
| Maximum RCF: | 30,367× g |
| Maximum Capacity: | 4 x 500 ml |
| Maximum Speed: | 18000 rpm |
| Maximum RCF: | 29684 × g |
| Maximum Capacity: | 6 × 100 ml |
| Max Speed: | 16000 rpm |
| Max RCF: | 27520 x g |
| Max Capacity: | 6x500 ml |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 21630 x g |
| Maximum Capacity: | 12 x 10 mL |
| Maximum Speed: | 22,000 RPM |
| Maximum RCF: | 33,873 × g |
| Maximum Capacity: | 6 × 100 mL |
| Max Speed: | 18000 rpm |
| Max RCF: | 31405 x g |
| Max Capacity: | 4 x 250 ml |
| Maximum Speed: | 21,000 rpm |
| Maximum RCF: | 31,405 × g |
| Maximum Capacity: | 4 × 750 ml |
| Max Speed: | 10000 rpm |
| Max RCF: | 18590 x g |
| Max Capacity: | 6x1000 ml |
| Max Speed: | 25000 rpm |
| Max RCF: | 65000 x g |
| Max Capacity: | 4x1000 ml |
| Speed: | 500 to 15000 rpm, increasement 100 rpm |
| RCF: | 100 to 21400×g |
| Temperature Range: | -20℃ to +40℃, under room temperature 25℃ |
| Max Speed: | 4500 rpm |
| Max RCF: | 3380 x g |
| Max Capacity: | 6 x 50 ml syringe |
| Max Speed: | 4700 rpm |
| Max RCF: | 2000 xg |
| Max Capacity: | 12 x 7 ml (SERO rotor) |
| Maximum Speed: | 4500 rpm (adjustable) |
| Maximum RCF: | 2000 × g (adjustable) |
| Maximum Capacity: | 12 × 2 mL tubes (12 mm × 75 mm) |
| Max Speed: | 4000 rpm |
| Max RCF: | 3400 xg |
| Max Capacity: | 4 x 200 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Max Speed: | 5000 rpm |
| Max RCF: | 5200 × g |
| Max Capacity: | 4 × 800 ml |
| Maximum Speed Range: | 6000 rpm |
| Maximum RCF: | 6880 × g |
| Maximum Capacity: | 6 × 1000 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123× g |
| Maximum Capacity: | 4x250 ml |
| Max Capacity: | 4 tubes, each 1000 ml |
| Max Speed: | 6000 rpm |
| Max RCF: | 6693×g |
| Max Speed: | 8000 rpm |
| Max RCF: | 14500 × g |
| Max Capacity: | 6x2400 ml / 12 blood bags / 384 blood tubes |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Maximum Speed: | 20000 rpm |
| Maximum RCF: | 27994 × g |
| Maximum Capacity: | 6x100 ml |
| Maximum Speed: | 16,500 rpm |
| Maximum RCF: | 24,814 × g |
| Maximum Capacity: | 6 × 100 ml |
| Maximum Speed: | 18500 rpm |
| Maximum RCF: | 24760 × g |
| Maximum Capacity: | 4x500 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 21630 × g |
| Maximum Capacity: | 12x5 ml |
| Maximum Speed: | 18000 rpm |
| Maximum RCF: | 24814 × g |
| Maximum Capacity: | 6x100 ml |
| Speed: | 500 to 15000 rpm, increasement 100 rpm |
| Maximum Sample Density: | 1.2g/ml |
| Acceleration/Deceleration : | Ⅰ (≤ 20) <br/> Ⅱ (≤ 40s) <br/> Ⅲ (≤ 60s) |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 18262× g |
| Maximum Capacity: | 8x5 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 15093× g |
| Maximum Capacity: | 8x5 ml |
| Speed: | 500 to 15000 rpm, 100 rpm increments |
| RCF: | 100 to 15000×g, 100×g increments |
| Maximum Rotor Radius: | 60 mm |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4499 x g |
| Maximum Capacity: | 4 x 600ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 4 × 250 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5200 × g |
| Maximum Capacity: | 4 × 500 ml |
| Max Speed: | 4200 rpm |
| Max RCF: | 2680 × g |
| Max Capacity: | 4x50ml;12x15ml tube/ blood tube/PRP tube |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123 × g |
| Maximum Capacity: | 6 × 50 ml |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 3580 x g |
| Maximum Capacity: | 4x1000 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 6 × 50 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 8 × 100 ml |
| Maximum Speed: | 4200 rpm |
| Maximum RCF: | 2680 × g |
| Maximum Capacity: | 24x10ml blood tube |
| Maximum Speed: | 4200 rpm |
| Maximum RCF: | 3285 × g |
| Maximum Capacity: | 4 × 100 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201x g |
| Maximum Capacity: | 4x800 ml |
| Speed Range: | 4000 rpm, 6000 rpm and 7000 rpm, adjustable |
| Maximum RCF: | 960×g, 4000 rpm <br/> 2200×g, 6000 rpm <br/> 2900×g, 7000 rpm |
| Capacity: | 6×1.5 ml/2.0 ml, 6×0.5 ml, 16×0.2 ml centrifuge tube <br/> 2×8×0.2 ml PCR tube strips |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 2000 g |
| Capacity (Standard): | 8 × 1.5 / 2.0 / 0.5 / 0.2 ml |
| Speed Range: | 500 to 12,000 rpm, 500 rpm increments |
| Maximum RCF: | 9,650 × g |
| Capacity: | 32 × 0.2 ml centrifugal tubes <br/> 12 × 0.5/1.5/2.0 ml centrifugal tubes <br/> 4 × 8 × 0.2 ml PCR strips |
| Maximum Speed: | 7500rpm |
| Maximum RCF: | 3450xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Maximum Speed: | 6000 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | ≤ 2 seconds |
| Speed Range: | 3000 to 10000 rpm |
| Maximum RCF: | 500 to 5400×g |
| Capacity: | 8×2.0ml/1.5ml/0.5ml centrifuge tube <br/> 4×8×0.2ml PCR tube strips |
| Maximum Speed: | 6000rpm |
| Maximum RCF: | 2200xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Speed Range: | 500 to 15000 rpm |
| RCF Range: | 16 to 15080 g |
| Capacity: | 12 x 1.5 / 2.0ml centrifuge tubes |
| Maximum Speed: | 10000rpm |
| Maximum RCF: | 6100xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml |
| Maximum Speed: | 3300 rpm |
| Maximum RCF: | 1920 x g |
| Maximum Capacity: | 8 x 30 ml |
| Capacity: | 24 Gel Cards (6 column / 8 column) |
| Speed Range: | 500 to 2200 rpm |
| Timing Range: | 1 min to 30 min |
| Maximum Speed: | 3840 rpm |
| Maximum RCF : | 1790 ×g |
| Capacity : | 24 gel card |
| Maximum Speed: | 3840 rpm |
| Maximum RCF: | 1790 xg |
| Maximum Capacity: | 12 Gel card |
| Maximum Speed: | 3000 rpm |
| Maximum RCF : | 890 × g |
| Maximum Capacity : | 12 cards |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 2170 xg |
| Maximum Capacity: | 10 pcs slide glass |
| Max Speed: | 3500 rpm |
| Max RCF: | 1640 xg |
| Max Capacity: | 12x10 ml |
| Max Speed: | 12000 rpm |
| Max RCF: | 15800 xg |
| Capacity: | 24pcs capillary tube |