| Speed | 500 to 15000 rpm, increasement 100 rpm |
| RCF | 100 to 21400×g |
| Temperature Range | -20℃ to +40℃, under room temperature 25℃ |
| Temperature Accuracy | ±2℃ at 4℃ |
| Cooling function |
Cool down to -20℃ when motor is not working Cool down to 4℃ when motor is working |
| Cooling Rate | ≤ 20 min at 4℃ |
| Acceleration/Deceleration Rate |
Ⅰ (≤ 20s) Ⅱ (≤ 40s) Ⅲ (≤ 60s) |
| Timer | 1s to 99m 59s, short spin available |
| Noise | 58 dB |
| Maximum Sample Density | 1.2g/ml |
| Power Consumption | 600 W |
| Power Supply | AC100 to 120V/AC200 to 240V, 50 to 60Hz |
| Dimensions (W×D×H) | 230×270×155 mm |
| Net Weight | 30 kg |
Our High Speed Refrigerated Centrifuge ADHSC-520 is equipped with a gentle braking system designed to protect delicate samples in laboratory applications.
Accessory | Description | Maximum Radius | Maximum RCF | Quantity |
Rotor 01 | 24 ×1.5ml/2.0ml tubes | 85 mm | 100 to 21400 ×g | 1 Pc |
Rotor 02 | 4×8×0.2 ml strips | 68 mm | 100 to 17100 ×g | 1 Pc |
Rotor 03 | 18×5ml (round bottom) | 85 mm | 100 to 21400 ×g | 1 Pc |
1. What is the QTemp function in the High Speed Refrigerated Centrifuge?
The QTemp function in High Speed Refrigerated Centrifuge enables rapid pre-cooling of the centrifuge chamber, ensuring it reaches optimal temperature quickly before sample processing begins. This helps reduce waiting time and improves efficiency in time-sensitive laboratory workflows. It also helps maintain sample integrity by minimizing exposure to temperature fluctuations.
2. How does the cooling function work in the High Speed Refrigerated Centrifuge?
This High Speed Refrigerated Centrifuge cools down to -20? when the motor is not running and maintains a temperature around 4? during operation. This dual-mode cooling ensures optimal thermal control throughout the process. It helps preserve temperature-sensitive samples by minimizing heat buildup during high-speed spins.
3. What feature of the High-speed Centrifuge helps safeguard delicate samples during use?
Our High-speed Centrifuge incorporates a soft brake function that gradually slows the rotor, minimizing disturbance to sensitive or layered samples. This smooth deceleration preserves sample integrity and ensures safe, reliable performance throughout the run.
4. Does the High-speed Centrifuge come with a TFT LCD display?
Yes, this High Speed Refrigerated Centrifuge features a TFT LCD touchscreen display that provides clear visuals and intuitive control for easy operation. The user-friendly interface simplifies parameter setting and real-time monitoring. Its high-resolution screen ensures visibility of operational status, even in low-light lab conditions.
5. How does the design of the High Speed Refrigerated Centrifuge ensure reliability and safety?
This High Speed Refrigerated Centrifuge features a robust and impact-resistant design that ensures long-term durability and dependable performance. Its sturdy construction provides added safety during high-speed operations. Built-in protective features help minimize risks. This design supports consistent results while prioritizing user and sample safety.
6. What is a High Speed Refrigerated Centrifuge?
A High Speed Refrigerated Centrifuge is a laboratory instrument that combines high rotational speeds with temperature control to efficiently separate biological samples while preserving their integrity. It is essential for processing heat-sensitive samples by preventing thermal degradation during centrifugation. These centrifuges are widely used in molecular biology, clinical diagnostics, and biochemistry labs.
7. Why is refrigeration important in centrifugation?
Refrigeration helps maintain low temperatures during centrifugation, preventing heat buildup that can degrade temperature-sensitive samples like proteins, enzymes, and nucleic acids. It also minimizes enzymatic activity and preserves the biological function and structure of delicate molecules. This ensures accurate and reliable experimental results.
8. Can the High Speed Refrigerated Centrifuge maintain temperature during the entire run?
Yes, the High Speed Refrigerated Centrifuge system continuously cools the rotor chamber to maintain the set temperature throughout the centrifugation process. This ensures that sensitive samples remain stable and protected from heat-induced damage. Consistent temperature control is critical for reproducible and accurate experimental results.
| Max Speed | 25000 rpm |
| Max RCF | 65000 x g |
| Max Capacity | 4x1000 ml |
| Max Speed | 18000 rpm |
| Max RCF | 31405 x g |
| Max Capacity | 4 x 250 ml |
| Max Speed | 10000 rpm |
| Max RCF | 18590 x g |
| Max Capacity | 6x1000 ml |
| Max Speed | 16000 rpm |
| Max RCF | 27520 x g |
| Max Capacity | 6x500 ml |
| Max Speed: | 4500 rpm |
| Max RCF: | 3380 x g |
| Max Capacity: | 6 x 50 ml syringe |
| Max Speed: | 4700 rpm |
| Max RCF: | 2000 xg |
| Max Capacity: | 12 x 7 ml (SERO rotor) |
| Maximum Speed: | 4500 rpm (adjustable) |
| Maximum RCF: | 2000 × g (adjustable) |
| Maximum Capacity: | 12 × 2 mL tubes (12 mm × 75 mm) |
| Max Speed: | 4000 rpm |
| Max RCF: | 3400 xg |
| Max Capacity: | 4 x 200 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Max Speed: | 5000 rpm |
| Max RCF: | 5200 × g |
| Max Capacity: | 4 × 800 ml |
| Max Capacity: | 4 tubes, each 1000 ml |
| Max Speed: | 6000 rpm |
| Max RCF: | 6693×g |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123× g |
| Maximum Capacity: | 4x250 ml |
| Max Speed: | 8000 rpm |
| Max RCF: | 14500 × g |
| Max Capacity: | 6x2400 ml / 12 blood bags / 384 blood tubes |
| Maximum Speed Range: | 6000 rpm |
| Maximum RCF: | 6880 × g |
| Maximum Capacity: | 6 × 1000 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Maximum Speed: | 16,500 rpm |
| Maximum RCF: | 24,814 × g |
| Maximum Capacity: | 6 × 100 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 21630 × g |
| Maximum Capacity: | 12x5 ml |
| Maximum Speed: | 18500 rpm |
| Maximum RCF: | 24760 × g |
| Maximum Capacity: | 4x500 ml |
| Maximum Speed: | 20000 rpm |
| Maximum RCF: | 27994 × g |
| Maximum Capacity: | 6x100 ml |
| Maximum Speed: | 18000 rpm |
| Maximum RCF: | 24814 × g |
| Maximum Capacity: | 6x100 ml |
| Speed: | 500 to 15000 rpm, increasement 100 rpm |
| Maximum Sample Density: | 1.2g/ml |
| Acceleration/Deceleration : | Ⅰ (≤ 20) <br/> Ⅱ (≤ 40s) <br/> Ⅲ (≤ 60s) |
| Speed: | 500 to 15000 rpm, 100 rpm increments |
| RCF: | 100 to 15000×g, 100×g increments |
| Maximum Rotor Radius: | 60 mm |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 18262× g |
| Maximum Capacity: | 8x5 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 15093× g |
| Maximum Capacity: | 8x5 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201x g |
| Maximum Capacity: | 4x800 ml |
| Maximum Speed: | 4200 rpm |
| Maximum RCF: | 3285 × g |
| Maximum Capacity: | 4 × 100 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 6 × 50 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4499 x g |
| Maximum Capacity: | 4 x 600ml |
| Max Speed: | 4200 rpm |
| Max RCF: | 2680 × g |
| Max Capacity: | 4x50ml;12x15ml tube/ blood tube/PRP tube |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123 × g |
| Maximum Capacity: | 6 × 50 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 4 × 250 ml |
| Maximum Speed: | 4200 rpm |
| Maximum RCF: | 2680 × g |
| Maximum Capacity: | 24x10ml blood tube |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 8 × 100 ml |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 3580 x g |
| Maximum Capacity: | 4x1000 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5200 × g |
| Maximum Capacity: | 4 × 500 ml |
| Speed Range: | 500 to 15000 rpm |
| RCF Range: | 16 to 15080 g |
| Capacity: | 12 x 1.5 / 2.0ml centrifuge tubes |
| Maximum Speed: | 6000rpm |
| Maximum RCF: | 2200xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Speed Range: | 4000 rpm, 6000 rpm and 7000 rpm, adjustable |
| Maximum RCF: | 960×g, 4000 rpm <br/> 2200×g, 6000 rpm <br/> 2900×g, 7000 rpm |
| Capacity: | 6×1.5 ml/2.0 ml, 6×0.5 ml, 16×0.2 ml centrifuge tube <br/> 2×8×0.2 ml PCR tube strips |
| Maximum Speed: | 7500rpm |
| Maximum RCF: | 3450xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 2000 g |
| Capacity (Standard): | 8 × 1.5 / 2.0 / 0.5 / 0.2 ml |
| Speed Range: | 500 to 12,000 rpm, 500 rpm increments |
| Maximum RCF: | 9,650 × g |
| Capacity: | 32 × 0.2 ml centrifugal tubes <br/> 12 × 0.5/1.5/2.0 ml centrifugal tubes <br/> 4 × 8 × 0.2 ml PCR strips |
| Maximum Speed: | 10000rpm |
| Maximum RCF: | 6100xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml |
| Speed Range: | 3000 to 10000 rpm |
| Maximum RCF: | 500 to 5400×g |
| Capacity: | 8×2.0ml/1.5ml/0.5ml centrifuge tube <br/> 4×8×0.2ml PCR tube strips |
| Maximum Speed: | 6000 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | ≤ 2 seconds |
| Maximum Speed: | 2800 rpm |
| Maximum RCF: | 600×g |
| Maximum Rotor Radius: | 63 mm |
| Maximum Speed: | 2500 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | 15 seconds |
| Rotating Speed: | 2200 to 2800 rpm |
| Maximum RCF: | 550 g |
| Capacity: | 2 PCR plates |
| Rotating Speed: | 500 to 2500 rpm |
| RCF Range: | 32 to 797g |
| Capacity: | 2 pcs Microplates or Deep-well plates |
| Maximum Speed: | 3300 rpm |
| Maximum RCF: | 1920 x g |
| Maximum Capacity: | 8 x 30 ml |
| Maximum Speed: | 3840 rpm |
| Maximum RCF: | 1790 xg |
| Maximum Capacity: | 12 Gel card |
| Capacity: | 24 Gel Cards (6 column / 8 column) |
| Speed Range: | 500 to 2200 rpm |
| Timing Range: | 1 min to 30 min |
| Maximum Speed: | 3840 rpm |
| Maximum RCF : | 1790 ×g |
| Capacity : | 24 gel card |
| Maximum Speed: | 3000 rpm |
| Maximum RCF : | 890 × g |
| Maximum Capacity : | 12 cards |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 2170 xg |
| Maximum Capacity: | 10 pcs slide glass |
| Max Speed: | 3500 rpm |
| Max RCF: | 1640 xg |
| Max Capacity: | 12x10 ml |
| Max Speed: | 12000 rpm |
| Max RCF: | 15800 xg |
| Capacity: | 24pcs capillary tube |