Automatic Tissue Processor ADAT-501

Automatic Tissue Processor ADAT-501

Our Automatic Tissue Processor ADAT-501 has 12 tanks, including three paraffin wax units for precise embedding. Each system offers optimal volume for effective reagent utilization. Its specimen holder supports multiple standard dehydrating boxes, enabling large-batch handling. A dual-control heating mechanism ensures consistent temperature stability without water. This Automatic Tissue Processor optimizes sample preparation through advanced, customizable operation cycles.


Capacity 1000 mL
Number of Tanks 12 tanks (including 3 paraffin wax tanks at the end)
Basket Capacity 60 specimens
Processing Time per Tank Programmable from 0 to 99 hours
Packaging Type Individually packed in a protective wooden case
Power Supply AC 220 V ± 10%, 50 Hz ± 10%
Power Consumption ≤ 500 W
External Dimensions (L × W × H) 1140 × 560 × 580 mm
Gross Weight 85 kg
  • Automatic abnormal processing
  • Double-control heating
  • Multiple running programs
  • Backup power supply
  • Environment-friendly exhaust

The Automatic Tissue Processor ADAT-501 is used in histopathology labs to prepare tissue samples for microscopic examination.

Reagent Bottle

9 pcs

Tissue Basket

1 pc

Exhaust Pipe

1 pc

Tissue Cassette

20 pcs

Fuse (5 A)

2 pcs

 Power Line

1 line

Automatic Tissue Processor ADAT-501 | Capacity 1000 mL | Number of Tanks 12 tanks (including 3 paraffin wax tanks at the end)
Automatic Tissue Processor ADAT-501 | Automatic abnormal processing | Double-control heating

Frequently Asked Questions of Automatic Tissue Processor ADAT-501

1. How many processing tanks does the Automatic Tissue Processor ADAT-501 have?

This unit features twelve tanks, including three dedicated paraffin wax units at the final stage. The arrangement supports a complete sequence of processing steps in a single run. Each tank is constructed for durability and chemical resistance. The configuration allows efficient reagent usage without unnecessary waste. Such capacity ensures high-throughput operation for busy laboratories.

2. What are the capacity and basket specifications of the Automatic Tissue Processor ADAT-501?

Each tank holds 1000 mL of processing reagent for optimal efficiency. The specimen basket accommodates up to sixty standard dehydrating boxes, allowing multiple samples to be handled simultaneously. This setup enhances productivity while maintaining precision in preparation. The design supports smooth transfer between tanks without damaging specimens. The combination of capacity and basket size makes it ideal for large-scale processing needs.

3. Does the Automatic Tissue Processor ADAT-501 offer programmable operation?

Yes, it includes customizable running programs to suit different specimen types and processing requirements. Technicians can set time intervals and temperatures for each stage independently. These programs help achieve consistent results across different batches. The flexibility minimizes the risk of processing errors. Advanced programming also supports overnight or unattended operation.

4. What additional features enhance the performance of the Automatic Tissue Processor ADAT-501?

Automatic Tissue Processor ADAT-501 uses a double-control heating system to maintain stable temperatures without water dependency. An eco-friendly exhaust design improves safety and reduces odors. A gear-rack transmission ensures smooth movement of the specimen basket. Backup power safeguards operations during brief outages. Together, these elements deliver reliable and efficient tissue processing.

5. How does the double-control heating system in the Automatic Tissue Processor ADAT-501 work?

The dual-control heating mechanism uses two independent sensors to regulate temperature precisely at each stage. This ensures uniform wax infiltration and prevents overheating. It operates without water, reducing maintenance and risk of contamination. Stable heat improves the quality of prepared specimens. Such precision is essential for accurate histological results.

6. What are Automatic Tissue Processors?

Automatic Tissue Processors automate the preparation of tissue samples through chemical treatments and embedding. They handle dehydration, clearing, and paraffin infiltration efficiently. These instruments ensure consistent and reliable specimen processing. This automation improves overall workflow in the laboratory.

7. Where are Automatic Tissue Processors used?

Automatic Tissue Processors are found in histopathology labs, research centers, and diagnostic facilities. They process tissue specimens for detailed microscopic examination. Their use supports accurate diagnosis and medical research. These processors are essential tools in pathology workflows.

Similar Products of Automatic Tissue Processor

Capacity 1500 mL
Number of Tanks 12 tanks (including 3 paraffin wax tanks at the end)
Basket Capacity 75 specimens
Capacity 2200 mL
Number of Tanks 12 tanks (including 3 paraffin wax tanks at the end)
Temperature Setting 0 to 99 °C
Capacity 200 (cassettes)
Number of Reagent Steps 9 reagent steps
Number of Paraffin Wax Steps 3 steps
Capacity 300 (cassettes)
Number of Reagent Steps 9 reagent steps
Number of Paraffin Wax Steps 3 steps

Spin Tissue Processor

Spin Tissue Processor ADSTP-501
Glass Containers:9 units <br> capacity 1.2 L each
Wax Cups :3 units <br> capacity 1 L each
Temperature Control Range :60 to 99 °C
Spin Tissue Processor ADSTP-502
Glass Containers:9 units <br> capacity 2.3 L each
Wax Cups :3 units <br> capacity 1.8 L each
Temperature Control Range :60 to 99 °C

Double Basket Tissue Processor

Double Basket Tissue Processor ADBTP-501
Capacity:2 L
Number of Reagent Containers :144
Processing Time :0 to 99 hours per container